Brand:

Viking Pump N324A Large Internal Gear Pump 600 GPM

Description

Overview

Viking Pump N324A is a high-capacity internal gear pump rated 600 GPM (136 m3/h) at 350 rpm, with 6 inch flanged ports in an opposite (straight-through) arrangement. It is the entry size of the 324A Series, which Viking Pump positions as the largest pumps in its Universal Product Line. Where a typical gear pump suits a drum filling station, the Viking Pump N324A is built for pipeline-scale transfer of viscous liquids such as fuel oil, crude residues, asphalt and heavy lubricants. Seven Star LLC is an independent supplier serving Oman and the GCC.

Unlike the smaller sizes, the N frame is cast with a foot-mounted casing and a jacketed bracket as standard, so heat from steam, hot oil or warm water can be circulated around the shaft seal area to keep sticky liquids mobile.

Why choose Viking Pump N324A for large transfer duties

The pump delivers constant, pulse-free flow because liquid is trapped between rotor teeth and carried around the crescent partition. That behaviour means flow does not collapse when viscosity rises, a limit that shortens centrifugal pump life on cold bitumen or heavy fuel. At 350 rpm the pump turns slowly, which reduces shear on the liquid and cuts wear in the bushings. The footed casing lets the whole pump sit on a baseplate without a separate bracket frame, and the large bearing housing supports a cartridge seal.

The catalog describes the 324A family as supporting component or cartridge mechanical seals, traditional packing and the O-Pro seal, with an optional jacketed head for more demanding thermal control. The Viking Pump N324A is the packed version, which carries braided PTFE packing.

Specifications

Parameter Value
Model Viking Pump N324A, 324A Series, cast iron, jacketed bracket
Port size 6 inch flanged, opposite ports at 180 degrees
Nominal capacity 600 GPM (136 m3/h)
Rated speed 350 rpm
Maximum hydrostatic pressure 250 PSIG (17 bar)
Maximum discharge pressure 200 PSI (14 bar)
Maximum temperature, standard pump 450 F (232 C)
Series temperature range -60 to +450 F (-50 to +230 C)
Viscosity range 28 to 2,000,000 SSU (0.1 to 440,000 cSt)
Shipping weight with valve 923.62 lb (419.2 kg)
Shaft Steel, ASTM A108 Grade 1045
Rotor Ductile iron on N size
Casing, head, bracket Cast iron, ASTM A48 Class 35B
Shaft sealing Braided PTFE packing

How N324A differs from other 324A variants

Three sizes make up the 324A Series. The Viking Pump N324A is the smallest at 600 GPM with 6 inch ports. R324A has 8 inch ports, delivers 1,100 GPM (250 m3/h) at 280 rpm and ships at 1,761.5 lb (799.5 kg). RS324A has 10 inch ports, delivers 1,600 GPM (364 m3/h) at 280 rpm and ships at 2,013.3 lb (913.8 kg); its maximum discharge pressure is limited to 125 PSI (8.5 bar), and the relief valve is not available on the RS.

Within the N size the codes N1324A and N4324A exist too: N1324A uses the O-Pro barrier seal, runs 550 GPM at 330 rpm and is rated to 350 F (175 C), and N4324A uses a mechanical seal at 600 GPM and 350 F. Viking Pump N324A keeps the full 450 F rating thanks to packing.

Typical applications in Oman and the GCC

Refineries and terminals use N-size gear pumps to load and unload road tankers with fuel oil, bitumen and lube base oil. Power plants use them for heavy fuel oil forwarding and for lube oil skids on large turbines. In water and wastewater plants they appear on sludge conditioner lines. Shipyards and bunker barges also rely on large internal gear pumps for tank stripping where the liquid is viscous.

Selection notes for Viking Pump N324A

Large gear pumps are rarely selected on flow alone. Pump speed, drive type and seal arrangement all alter life. At 350 rpm the N size is gentle on shear-sensitive liquids and gives long bushing life, but it needs a reducer from a 1450 or 1750 rpm motor, so allow for a reducer and guard on the baseplate. The 250 PSIG hydrostatic rating applies to standard construction, and actual limits depend on the seal, gaskets and port connections chosen.

  • Check head and flange loading: a 6 inch cast iron flange must not carry pipe weight.
  • Decide between packing and mechanical seal early; a mechanical seal limits temperature to 350 F.
  • Ask whether the optional jacketed head is needed when product freezes at ambient.
  • Use the performance curve generator for discharge pressure at your viscosity.
  • Confirm suction pressure is under 50 PSIG, otherwise obtain factory approval.

Foundation, installation and commissioning

Because the pump weighs over 900 lb without a drive, the baseplate and foundation should be designed as a unit with the reducer and motor. Grout the baseplate, align with a spacer coupling, and connect the jacket supply and return at the bracket before the first start. Pre-heat viscous product through the jacket, prime the casing, open both isolation valves and start against an open line. Adjust the packing gradually, and record the initial discharge pressure for future comparison.

Maintenance

Operators should log discharge pressure and motor current at commissioning; a slow rise in current at constant viscosity points to bushing wear, while falling flow points to growing end clearance. Inspect packing weekly and replace rings when adjustment is exhausted. Check the jacket for leaks and flush it when out of service in cold conditions. Use the rotatable bearing housing to reset end clearance to compensate for wear. Keep a spare idler, bushing set and relief valve on site, because delivery of large castings takes time.

Related items you may also need: Verderflex Rapide Peristaltic Tube Pump | Danfoss 180B0036 PAH 25 High-Pressure Water Pump | Allweiler EMTEC-C High-Pressure Coolant Supply Screw Pump | All Viking Pump products.

Documents and quotation

The attached catalog section lists the whole 324A, 1324A and 4324A range with dimensions, materials and options. To request a quotation for Viking Pump N324A, send the part number Viking Pump N324A and the quantity through the RFQ form and state the delivery site in Oman or elsewhere in the GCC.

Datasheets & Documents
  • PDF Datasheet Viking Pump N324A Large Internal Gear Pump 600 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.

FAQ

Questions about the Viking Pump N324A Large Internal Gear Pump 600 GPM

Answers from our engineering team on installation, compatibility and integration.

01What capacity is the N324A rated for?
The N324A is rated 600 GPM (136 m3/h) at 350 rpm through 6 inch opposite flanged ports for liquids of 100 SSU and below.
02Does the N324A have a jacketed bracket?
Yes, the N size is a foot-mount casing with a jacketed bracket as standard. The head is non-jacketed unless a jacketed head option is ordered.
03What is the maximum discharge pressure of the N324A?
The catalog lists 200 PSI (14 bar) maximum discharge pressure and 250 PSIG (17 bar) maximum hydrostatic pressure.
04What shaft seal does the N324A use?
It is supplied with braided PTFE packing. Mechanical seal and O-Pro seal versions are sold as N4324A and N1324A with a lower temperature rating.
05How heavy is the N324A?
The listed shipping weight with relief valve is 923.62 lb (419.2 kg), so a lifting plan and a heavy-duty baseplate are required.