Brand:

Victaulic Series 735 Fire Pump Test Meter with Dial Meter

Description

Overview

Victaulic Series 735 is the Victaulic fire pump test meter. It consists of a calibrated Venturi section with a dial meter attached, and it is designed for monitoring fire protection systems. The meter reads flow in gallons per minute or cubic metres per hour. It is installed on the discharge side of a fire pump with only two Victaulic couplings, which makes it a practical tool for acceptance testing and for annual pump performance checks.

The meter is used with FM Approved Victaulic products in 2 1/2 to 12 inch (65 to 300 mm) sizes. The datasheet offers two dial options: Model S has a 4 1/2 inch (120 mm) dial and is rated up to 500 psi (3450 kPa), while Model L has a 6 inch (150 mm) dial and is rated up to 175 psi (1200 kPa).

Seven Star LLC is an independent supplier serving Oman and the GCC.

Model and range data for Victaulic Series 735

Parameter Value
Product Fire pump test meter, Venturi with dial meter
Sizes 2 1/2 to 12 inch / 65 to 300 mm (size and rated flow combinations)
Model S 4 1/2 inch / 120 mm dial, up to 500 psi / 3450 kPa
Model L 6 inch / 150 mm dial, up to 175 psi / 1200 kPa
Units GPM or cubic metres per hour
Housing Steel, Schedule 40 to ASTM A53 for 4 inch and under; ASTM A53 Grade B for 5 inch and above
Cone Steel to ASTM A569
Needle valve Yellow brass to ASTM B124 (377), 1/4 inch NPT
Tubing Yellow brass to ASTM B16 (360)
2 1/2 inch, 100 GPM rating Model L range 40 to 200 GPM; Model S 60 to 200 GPM; end to end 4.00 inch
4 inch, 250 GPM rating Model L 100 to 500 GPM; Model S 160 to 500 GPM
6 inch, 750 GPM rating Model L 300 to 1500 GPM; Model S 450 to 1500 GPM; end to end 6.00 inch
8 inch, 1500 GPM rating Model L 600 to 3000 GPM; Model S 900 to 3000 GPM; end to end 7.00 inch
8 inch, 3000 GPM rating Model L 1000 to 6000 GPM; Model S 1900 to 6000 GPM
Weight, 6 inch Model L 20.0 lb / 9.1 kg; Model S 15.0 lb / 6.8 kg

How the test meter works

The Venturi narrows the flow and the resulting pressure difference is sensed through two brass tubes and displayed on the dial as flow. A needle valve allows the lines to be bled of air. The listed meter range shows the minimum and maximum flow for each rated pump size: for example a 750 GPM rated pump with a 6 inch meter reads from 300 to 1500 GPM on Model L, and 450 to 1500 GPM on Model S. Rating refers to the pump rating, so the meter size and range must be chosen against the pump nameplate flow.

A single pass through a calibrated Venturi produces a stable reading with a short straight run, which is a benefit on cramped pump room layouts.

Applications in Oman and the GCC

Civil defence authorities in the GCC often require fire pump performance tests at handover and annually after that. A permanent meter on the discharge test header avoids hiring a mobile flow meter and a water return hose for each test. Typical locations are pump rooms in towers, malls, industrial plants, airports and oil and gas terminals.

Selection guide for Victaulic Series 735

Pick the meter size from the pump connection size and the rated flow in the table, then choose the dial. Model S is the higher pressure meter at 500 psi, which is suitable for high-pressure pump systems and large towers, while Model L is easier to read with its 6 inch dial but is limited to 175 psi. Choose the units to match the local test form, GPM or cubic metres per hour. The datasheet is an older revision and the exact code must be confirmed before ordering.

How Series 735 differs from other flow measuring products

Series 779 is a venturi check valve and flow measuring kit that gives a flow reading from a check valve body. Victaulic Series 735 is a dedicated test meter with a dial, designed to be fitted in a test line, and rated up to 500 psi in the S version. It is not a custody transfer meter and should be used for fire pump performance monitoring.

Installation and use

Install on the pump discharge side with two Victaulic couplings, in line with the flow arrow. Open the needle valves to purge air from the sensing tubes, then run the pump to the test points and read the dial. Record the flow, pressure and speed at each point and compare them with the pump curve. Close the needle valves after the test and keep the meter dry.

Maintenance

Check the tubes for kinks, check the dial for damage, and verify the reading periodically against another reference. Keep the meter covered when not in use, because dust and moisture in the sensing tubes can cause errors. Replace the dial or tubing if readings become unstable.

Testing practice for fire pumps

A typical acceptance test records churn pressure, then the rated flow point and the 150 percent point, and the meter must cover each of these. For a pump rated at 750 GPM, the 150 percent point is 1125 GPM, which falls inside both ranges listed above. Make sure the discharge water can be returned to a tank or drained safely, since flows of thousands of GPM can flood a pump room.

Document results in a dated log along with the meter reference and the pump serial number so that later tests can be compared. If the meter reading differs noticeably from the pump curve, confirm the pump speed and suction conditions before suspecting the meter, and repeat the test after bleeding the sensing tubes. Where authorities witness the test, bring the datasheet and the meter model code so that the inspector can verify the range against the pump rating.

Related items you may also need: Victaulic FireLock Series 705 Butterfly Valve, Supervised Open | Victaulic Style 77 Standard Flexible Coupling | Victaulic Style 107N QuickVic Rigid Coupling | All Victaulic products.

Points to confirm for the Victaulic Series 735

  • If the Victaulic Series 735 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Victaulic Series 735 request we confirm the exact code, new or surplus condition and lead time in writing.
  • Dimensions, ratings and connection data for the Victaulic Series 735 are in the datasheet attached to this page.
  • The Victaulic Series 735 belongs to our differential pressure flowmeters range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
  • Plants that run the Victaulic Series 735 on critical service often hold a spare unit in the store.

Documents and quotation

The datasheet for Victaulic Series 735, publication 10.11, is attached. Send your RFQ with the pump rated flow, the pipe size, the dial model and the units so that we can confirm the correct meter row with you.

Datasheets & Documents
  • PDF Datasheet Victaulic Series 735 Fire Pump Test Meter with Dial Meter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.

Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.

Victaulic company profile

Origins 1919, grooved coupling patent
Name From 'victory' and 'hydraulic'
Headquarters Easton, Pennsylvania
Ownership Privately held
Product families Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools

Milestones

  • 1919: The grooved Victaulic coupling is patented.
  • 2019: Victaulic marks 100 years.

Victaulic Style 107N QuickVic couplings

The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.

Where Victaulic couplings are used and what to send

The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.

Facts checked against Victaulic's 100-year innovation timeline, October 2026.

Victaulic products we list

Family Examples
Pipes & Fittings Style 07 Zero-Flex Rigid Coupling, Style 107N QuickVic Rigid Coupling, Style 77 Standard Flexible Coupling
Fire Fighting FireLock Series 705 Butterfly Valve
Butterfly Valves Series 761 Vic-300 MasterSeal Butterfly…

FAQ

Questions about the Victaulic Series 735 Fire Pump Test Meter with Dial

Answers from our engineering team on installation, compatibility and integration.

01What does Victaulic Series 735 measure?
It is a fire pump test meter: a calibrated Venturi with an attached dial meter that reads flow in GPM or cubic metres per hour.
02What dial models are available?
Model S with a 4 1/2 inch (120 mm) dial rated to 500 psi, and Model L with a 6 inch (150 mm) dial rated to 175 psi.
03What pipe sizes are covered by Series 735?
2 1/2 to 12 inch (65 to 300 mm) for use with Victaulic FM Approved products, with rated flows from 100 up to 3000 GPM listed in the table.
04How is the meter installed?
On the discharge side of the pump with just two Victaulic couplings.
05What is the meter range for a 6 inch, 750 GPM pump?
Model L reads 300 to 1500 GPM and Model S reads 450 to 1500 GPM, according to the datasheet table.