Victaulic Series 717 FireLock Check Valve, 2 1/2 to 12 inch
Description
Overview
In a sprinkler or fire water system a check valve has one job that must never fail: it has to stop water running backward when pumps stop or when a section is drained. The Victaulic Series 717 FireLock check valve does this in a grooved body that goes straight into a carbon steel fire main. Seven Star LLC is an independent supplier serving Oman and the GCC. This page summarises publication 10.08, which covers the Victaulic Series 717 for sizes 2 1/2 to 12 inch and the Series 717H high-pressure version for 2 to 3 inch, and it points out the details that matter during design and replacement.
Design and rating
Inside the body is a single disc with a spring-assisted closing action, which the publication describes as non-slamming. That matters in fire systems, where water hammer from a slamming check valve can damage heads and joints. The valve may be installed horizontally or vertically, but in the vertical position the flow must be upward. An arrow is cast into the body to show the orientation, and select sizes have optional upstream and downstream pressure taps. Working pressure is up to 365 psi, 2517 kPa or 25 bar, depending on pipe size, valve size and approval requirements, and the valve is rated for ambient temperature in fire protection systems.
Data summary for Victaulic Series 717
| Item | Value |
|---|---|
| Product | FireLock check valve, Victaulic Series 717 and 717H |
| Sizes | 717H: 2 to 3 inch (DN50 to DN80); 717: 2 1/2 to 12 inch (73 mm to DN300) |
| Maximum working pressure | up to 365 psi / 2517 kPa / 25 bar |
| Mechanism | single disc, spring-assisted, non-slamming |
| Orientation | horizontal, or vertical with upward flow only |
| Pipe | carbon steel, Schedule 10 and Schedule 40 |
| Ends | grooved, Victaulic Original Groove System |
| Application | fire protection systems, prevents backflow |
| Options | upstream and downstream pressure taps on select sizes |
| Approvals referenced | cULus, LPCB (LPS 1186 issue 3.1, ref 104h/01) |
How Series 717 differs from the Series 717H and 717R
The same publication covers two variants. The 717H is the high pressure version for the 2 to 3 inch range, with service pressure of 2517 kPa listed under cULus and 2500 kPa under LPCB. The base 717 spans 2 1/2 to 12 inch. A separate publication describes the Series 717R, which is supplied with a riser check kit for alarm check valve applications. If your project calls for a riser assembly with trim, the 717R is the intended product; for in-line backflow prevention, such as at a pump discharge or between zones, the 717 is the normal choice.
Applications in Oman and the GCC
Look for it on fire pump discharge lines, between a jockey pump and the main, on connections to tanks and on branches that feed several risers. Large facilities in the region, such as refineries, airports, residential towers and logistics hubs, rely on grooved fire protection systems because they are quick to install and easy to modify. The listed approvals for the product depend on size and pressure, so the contractor should confirm that the selected valve carries the approval the local authority requires.
Selection checklist
- Size: 2 to 3 inch for the 717H, 2 1/2 to 12 inch for the 717.
- Confirm maximum system pressure, including pump churn pressure, against 365 psi.
- Decide whether pressure taps are needed on the chosen size.
- Install with the arrow in the flow direction and, if vertical, with flow upward.
- Check the approvals required by the local fire authority.
Installation
Groove the pipe ends to the standard, fit the valve between two couplings and make sure the arrow points downstream. Allow room to remove the cover for inspection, and support the pipe on each side of the valve because the body is heavy in larger sizes. Flush the system before commissioning, because debris that lodges between the disc and seat will cause leakage. After filling, test the valve by checking that pressure holds on the downstream side when the upstream pressure is reduced.
Inspection and testing of Victaulic Series 717
Fire protection standards require periodic checks of check valves. During those checks, look for external leaks, verify that the arrow orientation has not changed after maintenance, and test closure under controlled conditions. If the valve has been dismantled, replace the seal elements and verify the spring action. Keep records so that the next inspection can compare results.
Why correct selection saves time
A check valve of the wrong pressure class or size can delay acceptance testing. Our team can compare the figures from your design with the publication before you order, which reduces the risk of returns. When you request a quotation, include the size, pressure, quantity and the approval required by your project, and tell us whether pressure taps are needed.
When you replace a valve, record the old valve’s size and markings first. The size is cast in the body, and the arrow shows the flow direction; a photograph of both is often enough for us to identify a match. If the old valve is a different pattern, we can discuss whether the 717 is a suitable substitute in your layout.
Because fire systems sit idle for years between events, small defects have time to grow. A check valve that leaks slowly may let a pump drain back overnight, and the jockey pump will then cycle often, a symptom that maintenance teams should treat as a warning that should be investigated. Likewise, if a pressure gauge on the downstream side drops while the upstream line is stable, the check valve is the first component to examine. Pressure taps, where fitted, make this diagnosis easier because the two sides of the valve can be compared directly without opening the line, which saves time during every scheduled inspection.
Related items you may also need: Victaulic Style 107N QuickVic Rigid Coupling | Victaulic FireLock Series 705 Butterfly Valve, Supervised Open | Victaulic Style 07 Zero-Flex Rigid Coupling | All Victaulic products.
Checklist before ordering the Victaulic Series 717
- Before ordering the Victaulic Series 717, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
- Our team confirms the Victaulic Series 717 code and lead time in writing before any order is placed.
- The datasheet attached to this page is the reference for the Victaulic Series 717 dimensions, ratings and connections.
- The Victaulic Series 717 is listed in our check valves range and ships to sites across Oman and the GCC.
- Spare quantities of the Victaulic Series 717 are worth planning for critical duty so that a failure does not stop production.
Details needed to quote the Victaulic Series 717
The Victaulic Series 717 is a product style that is supplied in many sizes and material combinations, so a single order line is defined by the details below rather than by the style name alone.
- Nominal size of the Victaulic Series 717 and the pipe outside diameter it must fit (IPS or metric).
- Pipe end preparation: roll grooved, cut grooved or plain end, and the pipe material.
- Body and trim materials, seat or seal elastomer grade, and the fluid and temperature it must handle.
- Working pressure required and any approval needed for the service, for example fire protection listings.
- Operator or accessory options, such as lever, gear operator, tamper switch or test and drain fittings, where the valve offers them.
Send these details, or the Victaulic part number from an existing installation or drawing, and the quotation will confirm the exact orderable item and the matching gasket.
Documents and quotation
The manufacturer’s publication 10.08 is attached. Send your RFQ with Victaulic Series 717, the size, quantity and delivery location in Oman or the GCC.
Other Models in the Victaulic Valve Range
Seven Star LLC supplies models from the Victaulic Valve range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Victaulic Series 726 Vic-Ball Valve, Grooved, DN40-DN150 | Ball Valves | View details |
| Victaulic Series 713 Swing Check Valve DN50 to DN100 | Check Valves | View details |
| Victaulic Series 717 FireLock Check Valve, 2 1/2 to 12 inch | Check Valves | You are viewing this model |
Datasheets & Documents
- Datasheet Victaulic Series 717 FireLock Check Valve, 2 1/2 to 12 inch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Victaulic is an American maker of grooved mechanical pipe joining systems, valves and fire protection products, headquartered in Easton, Pennsylvania. Its grooved coupling was patented in 1919 by Ernest Tribe, and the name combines 'victory' and 'hydraulic'. Victaulic is privately held and reinvests in its own plants and technology.
Seven Star LLC lists Victaulic couplings and butterfly valves, among them the Style 107N QuickVic rigid coupling, and supplies Victaulic couplings and fittings for mechanical, utility and process piping in Oman on inquiry.
Victaulic company profile
| Origins | 1919, grooved coupling patent |
|---|---|
| Name | From 'victory' and 'hydraulic' |
| Headquarters | Easton, Pennsylvania |
| Ownership | Privately held |
| Product families | Style 07, 77 and 107N grooved couplings, Vic-300 MasterSeal butterfly valves, FireLock fire protection valves and sprinklers, grooved fittings and tools |
Milestones
- 1919: The grooved Victaulic coupling is patented.
- 2019: Victaulic marks 100 years.
Victaulic Style 107N QuickVic couplings
The Style 107N is a rigid coupling for roll-grooved or cut-grooved carbon steel and stainless steel pipe in sizes from 2 to 12 inches (DN 50 to DN 300). Victaulic rates it from full vacuum up to 750 psi (5171 kPa), but the working pressure of a given joint depends on pipe material, wall thickness and size. The housing has an angled bolt pad that makes the joint rigid, and a galvanized finish is optional.
Where Victaulic couplings are used and what to send
The manufacturer names HVAC, utility and process piping as the applications for this style. For an inquiry, send the style number, nominal size, pipe material and schedule, the fluid and temperature so the gasket grade can be checked, the housing finish and the quantity. GCC consultants often ask for the submittal sheet, which we provide from the manufacturer.
Facts checked against Victaulic's 100-year innovation timeline, October 2026.
Browse Victaulic products by category: Pipes & Fittings.
Victaulic products we list
FAQ
Questions about the Victaulic Series 717 FireLock Check Valve, 2 1/2 to
Answers from our engineering team on installation, compatibility and integration.
01What is the Victaulic Series 717 used for?
It is a FireLock check valve for fire protection systems that prevents backflow, with a spring-assisted single disc for non-slamming operation.
02What sizes does the Series 717 cover?
The Series 717 covers 2 1/2 to 12 inch, while the 717H high-pressure version covers 2 to 3 inch.
03What is the maximum working pressure of the Victaulic Series 717?
Up to 365 psi, 2517 kPa or 25 bar, depending on pipe size, valve size and approval requirements.
04Can the Series 717 be installed vertically?
Yes, it can be installed horizontally or vertically, but in vertical orientation the flow must be upward only.
05Does the Series 717 have pressure taps?
Optional upstream and downstream pressure taps are available on select sizes according to publication 10.08.