Schneider Electric LC1D38U7 38 A TeSys Deca Contactor
Description
What the LC1D38U7 is and how the reference reads
The LC1D38U7 is a Schneider Electric TeSys Deca contactor that the datasheet describes as TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 38 A – 240 V AC 50/60 Hz coil. The 38 A contactor sits in the same 85 x 45 x 92 mm body as the 32 A, but the AC-3 current rises to 38 A and the 380/400 V motor rating to 18.5 kW. Its AC-1 rating stays at 50 A, identical to the 32 A device. Seven Star LLC supplies the LC1D38U7 in Oman and the GCC as an independent supplier based in Muscat.
The code breaks down as LC1D (three-pole TeSys Deca contactor), 38 (the 38 A frame) and U7 (the coil version). The coil row of the datasheet states 240 V AC 50/60 Hz, which is how the suffix should be understood for this reference.
That matters when you buy for a heater: the extra AC-3 capability does not increase the resistive rating, so the 38 A part is justified by motor duty rather than by furnace or heater duty.
Technical specifications of the LC1D38U7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LC1D38U7 |
| Description | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 38 A – 240 V AC 50/60 Hz coil |
| Range | TeSys Deca Advanced |
| Device short name | LC1D |
| Poles / contact composition | 3P / 3 NO |
| Contactor application | Resistive load; Motor control |
| Utilisation categories | AC-3; AC-3e; AC-1; AC-4 |
| Rated operational voltage | Power circuit: <= 690 V AC 25 to 400 Hz; Power circuit: <= 300 V DC |
| Rated operational current AC-3 (≤440 V) | 38 A (below 60 °C) |
| Rated operational current AC-1 | 50 A at up to 440 V AC (below 60 °C) |
| Control circuit voltage | 240 V AC 50/60 Hz |
| Rated breaking capacity | 550 A at 440 V for power circuit |
| Associated gG fuse, coordination type 1 / type 2 | 63 A / 63 A |
| Rated insulation voltage Ui / impulse Uimp | 690 V / 6 kV |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.4 million cycles at 38 A in AC-3 and 1.4 million cycles at 50 A in AC-1 (Ue up to 440 V) |
| Coil technology | Without built-in suppressor module |
| Inrush / hold-in power (50 Hz) | 70 VA / 7 VA |
| Operating time | 4 to 19 ms opening; 12 to 22 ms closing |
| Auxiliary contacts | 1 NO + 1 NC |
| Mounting | Rail; Plate |
| Ingress protection | IP20 front face conforming to IEC 60529 |
| Ambient temperature around the device | -40 to 60 °C |
| Dimensions H x W x D | 85 mm x 45 mm x 92 mm |
| Net weight | 0.38 kg |
| Certifications listed | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
What the LC1D38U7 can start: AC-3 motor power by voltage
| Supply voltage (AC, 50/60 Hz) | Motor power in AC-3 (kW) |
|---|---|
| 220/230 V | 9 kW |
| 380/400 V | 18.5 kW |
| 415/440 V | 18.5 kW |
| 500 V | 18.5 kW |
| 660/690 V | 18.5 kW |
The table covers direct-on-line starting duty; the datasheet converts the 38 A rating into the motor powers above for each supply voltage. At 380/400 V the LC1D38U7 is listed for 18.5 kW. For heavier duty such as inching or plugging the AC-4 category applies and the datasheet lists 7.5 kW at 400 V, which is lower because those duties wear the contacts faster. The same device is rated 50 A in AC-1, the category for resistive loads such as heaters, so it can switch a higher current when the load is not a motor.
Control voltage behaviour of the LC1D38U7 on a 240 V AC supply
According to the datasheet the contactor operates between 0.8 and 1.1 times Uc at 50 Hz, which for this coil is about 192 V to 264 V, and between 0.85 and 1.1 times Uc at 60 Hz (204 V to 264 V). Drop-out occurs between 0.3 and 0.6 times Uc, about 72 V to 144 V, which is the range to remember when a weak control supply makes the contactor chatter instead of opening cleanly.
The coil of the LC1D38U7 is rated 240 V AC at 50/60 Hz. That fits a 240 V control supply; in Oman the phase-to-neutral voltage of the 415 V network is normally in this region, so the coil can be fed directly from phase and neutral.
Inrush is 70 VA at 50 Hz (70 VA at 60 Hz) and hold-in is 7 VA (7.5 VA at 60 Hz). Dividing by the coil voltage gives roughly 0.29 A on closing and 0.03 A when held; these are calculated approximations for sizing the control transformer or PLC interposing relay, not datasheet figures. The datasheet gives closing in 12 to 22 ms and opening in 4 to 19 ms.
The coil is described as without built-in suppressor module, so inductive switching of the coil can disturb sensitive electronics on the same control circuit unless a suppressor is added separately; check accessory compatibility with the supplier before ordering one.
Short-circuit data and contact life for the LC1D38U7
Contact life is stated as 15 Mcycles mechanically and, electrically, 1.4 million cycles at 38 A in AC-3 and 1.4 million cycles at 50 A in AC-1 (Ue up to 440 V). The maximum operating rate is 3600 cyc/h at 60 °C. For functional-safety calculations the datasheet gives a B10d of 1,369,863 cycles at nominal load and 20,000,000 cycles at mechanical load, per EN/ISO 13849-1.
The auxiliary block built into the LC1D38U7 is 1 NO + 1 NC; the datasheet notes the contacts are mechanically linked and that the NC is a mirror contact to IEC 60947-4-1, so it can be used in a safety circuit to prove that the main contacts have opened. The signalling circuit is specified for a minimum of 17 V and 5 mA.
For short-circuit protection the datasheet pairs the LC1D38U7 with a 63 A gG fuse at up to 690 V for coordination type 1 and 63 A gG for type 2. Type 2 is the stricter level: the contactor must remain usable after a fault, with at most light welds that can be separated. The rated breaking capacity is 550 A at 440 V for power circuit and the short-time withstand current is listed as 60 A 40 °C – 10 min for power circuit for the power circuit.
Frame comparison around the LC1D38U7
Other coil versions of the same frame that we handle are LC1D38B7, LC1D38F7; they carry the same power circuit and differ only in the coil voltage. Above it the range moves to a taller and wider body starting at 40 A, so panel space has to be re-checked when stepping up.
| Frame | AC-3 current | AC-3 kW at 380/400 V | AC-1 current | Body H x W x D | Net weight | Mechanical life |
|---|---|---|---|---|---|---|
| LC1D32.. | 32 A | 15 kW | 50 A | 85 x 45 x 92 mm | 0.375 kg | 15 Mcycles |
| LC1D38 (this frame) | 38 A | 18.5 kW | 50 A | 85 x 45 x 92 mm | 0.38 kg | 15 Mcycles |
| LC1D40A.. | 40 A | 18.5 kW | 60 A | 122 x 55 x 120 mm | 0.85 kg | 6 Mcycles |
With 18.5 kW at 400 V it covers larger pumps, ventilation units and compressors that would overload the 32 A frame, without moving to the wider body.
Choosing the LC1D38U7: checklist and RFQ details
| Question | What the datasheet tells you |
|---|---|
| Which load? | 38 A AC-3, 50 A AC-1 |
| Which control supply? | 240 V AC (limits above) |
| How much room? | 85 mm x 45 mm x 92 mm, 0.38 kg |
| How is it protected? | 63 A gG type 1 / 63 A type 2 |
| What else is needed? | Overload relay, auxiliary blocks, quantity |
When you send an RFQ, include the part number, quantity, control voltage, the motor or load data, and whether you want the unit for a new panel or to replace an installed LC1D contactor.
Commissioning the LC1D38U7 step by step
Commissioning starts with the control circuit. Energise the 240 V AC coil at the supply you will actually have in service, and confirm that the contactor closes at the lower operating limit of about 192 V and drops out cleanly. Then check the power-terminal torque of 2.5 N.m, measure phase rotation to the motor, and test the overload relay trip circuit. Ambient around the device is listed as -40 to 60 °C, so confirm the panel temperature during summer load.
Where the LC1D38U7 earns its place in Gulf plants
For OEM skid builders exporting to the GCC, a 240 V AC coil on a 38 A contactor keeps spares uniform across machines. Panel builders in the region also use the LC1D38U7 for motor control centres where a standard contactor frame simplifies spare-part stocking.
On construction and industrial sites around Muscat, Sohar and Salalah the LC1D38U7 replaces or extends starters on conveyors, crushers, compressors and washdown pumps. Dust and humidity make enclosure ratings and regular cleaning important. The datasheet lists a protective treatment of TH conforming to IEC 60068-2-30, which is relevant for damp heat.
Documents and quotation
A datasheet for the LC1D38U7 is attached on this page, listing the electrical, mechanical and environmental data used above. Send us the part number, quantity and application and we will confirm availability and a quotation.
Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Lc1d 38 Range
Seven Star LLC supplies models from the Se Lc1d 38 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LC1D38B7 38 A TeSys Deca Contactor | Contactors & Overload Relays | View details |
| Schneider Electric LC1D38F7 38 A TeSys Deca Contactor | Contactors & Overload Relays | View details |
| Schneider Electric LC1D38U7 38 A TeSys Deca Contactor | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LC1D38U7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LC1D38U7 38 A TeSys Deca
Answers from our engineering team on installation, compatibility and integration.
01What is the rated current of the LC1D38U7?
The datasheet lists 38 A in AC-3 and 50 A in AC-1 at up to 440 V AC, both for operation below 60 °C.
02What coil does the LC1D38U7 use?
The control circuit voltage is 240 V AC 50/60 Hz. It is an AC coil for 50/60 Hz without a built-in suppressor module.
03What fuse protects the LC1D38U7?
The datasheet gives 63 A gG at up to 690 V on the power circuit for type 1 coordination, and 63 A for type 2. Follow the coordination table for the motor and overload relay in use.
04Does the LC1D38U7 have auxiliary contacts?
The datasheet lists 1 NO + 1 NC, mechanically linked, with the NC acting as a mirror contact to IEC 60947-4-1.
05What ambient temperature is allowed for the LC1D38U7?
The permissible ambient around the device is -40 to 60 °C. Operating altitude is 0 to 3000 m.


















Reviews