Brand: Rotork
Rotork CVL-500 Linear Electric Control Valve Actuator
Description
The Rotork CVL-500 is the smallest member of the CVA linear family, a compact electric actuator built to push and pull the stem of a globe-style control valve without any compressed air. If your plant still positions small and medium control valves with pneumatic diaphragm heads, a positioner and an instrument-air header, the Rotork CVL-500 is the part number that replaces that whole chain with a single 4 to 20 mA device. It delivers 500 lbf (2,224 N) of rated thrust over a maximum stroke of 1.5 in (38.1 mm).
Rotork CVL-500 at a glance
- Rated thrust 2,224 N (500 lbf); the settable minimum is 40 percent of that, 890 N (200 lbf).
- Maximum stroke 38.1 mm (1.5 in) at up to 6.35 mm/s (0.25 in/s), giving a full-stroke time of 6 seconds at the 100 percent speed setting.
- Unit weight approximately 16 kg (35 lb), the lightest of the six CVA models.
- Brushless DC motor with S9 unrestricted modulation duty and 4 to 20 mA command and feedback as standard.
Because the stroke is short and the travel time is only 6 seconds, the Rotork CVL-500 suits fast loops such as steam-to-heat-exchanger temperature control, small flow trims and chemical dosing valves where the process responds in seconds rather than minutes.
How the Rotork CVL-500 positions the valve
Two independent 12-bit rotary magnetic encoders, one on the motor and one near the output shaft, are compared continuously. This dual-sensor arrangement removes backlash and gear inertia from the measurement, which is how the CVA family reaches a quoted resolution of 0.1 percent of the signal range with linearity of 0.5 percent or better. A thrust sensor based on a Wheatstone bridge measures the real force at the stem and acts as the primary protection for both motor and valve, so the CVL-500 can be told to stop at a chosen force instead of relying on a torque switch or thermal trip.
Thrust is measured to within plus or minus 5 percent of rated force, and operating times carry a tolerance of plus or minus 10 percent. Speed can be reduced anywhere between 5 and 100 percent of the table value when a slower, steadier loop is preferable. Backdrive forces from the valve up to 125 percent of rated thrust are resisted without any creep, and an optional solenoid lock extends that to 300 percent for fail-in-place duty.
Technical specifications of Rotork CVL-500
| Model | CVL-500 (linear) |
|---|---|
| Rated thrust | 500 lbf / 2,224 N |
| Minimum settable thrust | 200 lbf / 890 N (40 percent) |
| Maximum stroke | 1.5 in / 38.1 mm |
| Speed at 100 percent | 0.25 in/s / 6.35 mm/s |
| Full stroke time | 6 s |
| Weight | Approximately 16 kg (35 lb) |
| Valve interface | MSS SP-102 FA07 / ISO 5210 F07; 4 holes M8 x 1.25 x 18 mm deep on a 70 mm PCD (5/16 in UNC alternative) |
| AC supply | 100 to 240 VAC, 50/60 Hz, plus or minus 10 percent, maximum 2 A |
| DC supply | 24 VDC plus or minus 10 percent, maximum 7 A |
| Reserve powerpack charge time | 30 s |
| Enclosure | IP66 / IP68 (7 m, 72 h), Type 4 and 6 |
| Ambient range | -30 to +60 C standard; -40 to +60 C low-temperature option |
| Cable entries | 4 x M25 (3/4 in NPT alternative) |
| Design life | 40 million 1 percent strokes at 75 percent load; 20 million 10 percent strokes at 100 percent load |
Power draw of the CVL-500 on a 240 V supply
Rotork publishes measured consumption for each model. For the Rotork CVL-500 on 240 VAC the actuator draws 5.3 W (0.07 A) while stationary, 14.7 W (0.14 A) running at full speed with no load, 29.3 W (0.22 A) at half load and 32.1 W (0.24 A) at full load. The peak while charging the optional super capacitor pack is 55 W (0.36 A), and a continuous 0.5 Hz, 2 percent cycling test at full load averages 17.55 W. Those figures are small enough that a single 2 A supply circuit is generous, and the low modulating consumption comes from regenerated motor energy being stored and reused when the motor reverses.
Where the CVL-500 earns its place
In Omani and wider GCC plants the CVL-500 is typically specified where instrument air is scarce or unreliable: remote wellpad skids, desalination dosing stations, wastewater lift stations and utility steam letdown. Because it needs only a power cable and a signal pair, it can be added to an existing globe valve through the 70 mm PCD mounting pattern and a stem coupling machined for the valve. The enclosure is rated IP68, so a flooded valve pit or washdown does not threaten the electronics, and the Bluetooth commissioning means covers are never removed on site.
Hazardous-area builds: CVA enclosures are available with ATEX, UKEx and IECEx marking in the form Ex db h [ia IIC Ga] IIB T4 Gb together with Ex h [ia IIIC Da] tb IIIC T120C Db, plus IIC and increased-safety variants, all with ambient limits of -20 to +60 C (or -40 to +60 C with the low-temperature option). The intrinsically safe interface for control circuits is an optional extra. For the CVL-500 the datasheet lists flamepaths with a maximum gap of 0.15 mm and minimum lengths of 25 mm or more.
How CVL-500 differs from other CVA variants
| Versus CVL-1000 | Half the thrust (2,224 N against 4,448 N), stroke 38.1 mm against 50.8 mm, but much faster: 6 s against 20 s; 8 kg lighter |
|---|---|
| Versus CVL-1500 | One third of the thrust (6,672 N for CVL-1500) and a 20 s stroke time instead of 6 s |
| Versus CVL-5000 | One tenth of the 22,241 N thrust, 38.1 mm against 114.3 mm stroke, and 16 kg against 51 to 53 kg |
| Versus CVQ-1200 / CVQ-2400 | Linear stem motion instead of quarter-turn torque; use CVQ for rotary valves |
The CVL-500 also carries the highest endurance rating of the range, 40 million small strokes, because its lighter duty allows less wear per cycle.
Installing and commissioning the CVL-500
Mount the actuator on the valve yoke with four M8 screws, couple the stem, then use the quick-setup routine: the CVL-500 drives itself to both stops and records the limits, measures thrust and builds the position scale. Settings are changed with the Enlight application over Bluetooth, and the actuator status LED at the centre of the selector shows green, blue or red for run, communication and fault states. The three-position selector (Run, Stop, Test) is magnetic and can be padlocked. The Test position runs a step-and-cycle routine and reports deadtime, T86 response, settling time, force in each direction, stroke speed and valve friction.
Maintenance and spares for Rotork CVL-500
The geartrain is lubricated for life, the motor is brushless and the covers stay closed, so routine work is limited to checking conduit seals, the stem coupling and the thrust reference. Recording a reference stroke after commissioning lets technicians compare later strokes and spot rising valve friction before packing or seat trouble causes a control problem.
Ordering notes for Rotork CVL-500
State the supply (AC or 24 VDC), the stem coupling dimensions, whether a hand drive, solenoid lock, reserve powerpack, HART, Pakscan, Profibus, Foundation Fieldbus or Modbus option is needed, and the hazardous-area certification. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
The Rotork CVA range brochure with the performance and specification tables is attached as the datasheet for the CVL-500. When you send the RFQ, include part number CVL-500, quantity, supply voltage, stem size and any fieldbus or certification requirement so the quotation can be matched to your valve.
Other Models in the Rotork Cva Range
Seven Star LLC supplies models from the Rotork Cva range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rotork CVQ-1200 Quarter-Turn Electric Control Actuator | Electric Actuators | View details |
| Rotork CVL-1500 Electric Linear Actuator 6,672 N | Electric Actuators | View details |
| Rotork CVL-5000 Heavy-Duty Electric Linear Actuator | Electric Actuators | View details |
| Rotork CVQ-2400 Quarter-Turn Electric Actuator 271 Nm | Electric Actuators | View details |
| Rotork CVL-1000 Linear Electric Actuator 4,448 N | Electric Actuators | View details |
| Rotork CVL-500 Linear Electric Control Valve Actuator | Electric Actuators | You are viewing this model |
Datasheets & Documents
- Datasheet Rotork CVL-500 Linear Electric Control Valve Actuator Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rotork is a British flow control company best known for electric valve actuators. Jeremy Fry founded Rotork Engineering Company in Bath in 1957, the year its first actuator, the 100A, went on sale, and the group is still headquartered in Bath and listed on the London Stock Exchange. Today Rotork makes electric, pneumatic, hydraulic and electro-hydraulic actuators, gearboxes, precision regulators and valve positioners.
Seven Star LLC is an independent supplier listing Rotork actuators, Rotork Fairchild regulators, YTC positioners and spare parts for buyers in Oman and the GCC. Replacement units are matched from the actuator nameplate and wiring diagram number.
Rotork company profile
| Origin | Founded by Jeremy Fry in 1957 in Bath, England; first product the 100A valve actuator |
|---|---|
| Headquarters | Brassmill Lane, Bath, United Kingdom |
| Ownership | Rotork plc, a public company listed on the London Stock Exchange |
| Acquired brands | Fairchild precision pneumatic controls (2011, Winston-Salem, USA), YTC valve positioners (Young Tech Co., Seoul, 2014), Mastergear gearboxes (2016) |
| Product families | Intelligent electric actuators, control valve actuators, electro-hydraulic and fluid power actuators, gearboxes, precision regulators, positioners and network control systems |
Milestones
- 1957: Jeremy Fry founds Rotork in Bath, England; the first product is the 100A valve actuator.
- 2011: Fairchild precision pneumatic controls (Winston-Salem, USA) is acquired.
- 2014: YTC valve positioners (Young Tech Co., Seoul) is acquired.
- 2016: Mastergear gearboxes is acquired.
Rotork actuators, regulators and positioners
| Series | Type | Typical use |
|---|---|---|
| IQ3 | Intelligent multi-turn electric actuator | Gate and globe valves, penstocks and sluice gates; non-intrusive setup with a Bluetooth setting tool, double-sealed enclosure, data logging |
| IQT3 | Intelligent part-turn electric actuator | Ball, butterfly and plug valves and dampers, with the same setup and diagnostics as IQ3 |
| CVA | Precision control valve electric actuator | Continuous modulating control of linear and part-turn control valves where instrument air is not available |
| CMA | Compact modulating electric actuator | Small control valves, chemical injection and metering pumps |
| Skilmatic SI3 | Self-contained electro-hydraulic actuator | Spring-return fail-safe and ESD duty with partial stroke testing, needing only an electrical supply |
| GP / GH | Scotch yoke pneumatic (GP) and hydraulic (GH) actuators | Large quarter-turn valves on pipelines and ESD service; spring-return or double-acting |
| CP | Compact pneumatic quarter-turn actuator | Smaller on-off ball and butterfly valves on plant air |
| Fairchild 10, 30, 55, 66, M11, 81 | Precision pressure regulators | Instrument air to positioners and actuators, test benches; Model 66 in stainless steel for corrosive and offshore sites |
| Fairchild 1000 | No-bleed precision regulator | Saves instrument air or gas where continuous bleed is not acceptable |
| Fairchild 10BP, 4000ABP | Back pressure regulators | Holding upstream pressure in process and test systems |
| YTC YT-1000, YT-3300 | Valve positioners | Electro-pneumatic (YT-1000) and smart HART (YT-3300) positioning of linear and rotary pneumatic actuators |
Where Rotork equipment is used
Rotork actuators are common on oil and gas pipelines and terminals, refineries and gas plants, water and wastewater networks, desalination plants and power stations. Electric IQ actuators handle isolation valves on long pipelines and water mains, often networked over Rotork Pakscan, Modbus or another fieldbus. Skilmatic and scotch yoke actuators cover emergency shutdown valves, and Fairchild regulators and YTC positioners sit on pneumatic control valves throughout process plants.
Ordering Rotork actuators and spare parts: what we need
Send photos of the actuator nameplate with the model, serial number and wiring diagram number; the wiring diagram is usually inside the terminal cover. Rotork can identify the original build, including options and control interface, from the serial number. For a new application add the valve type and size, required torque or thrust, operating time, mounting flange (ISO 5210 or ISO 5211), power supply, control signal or network protocol, fail-safe requirement and hazardous-area marking. For regulators and positioners send the full model code and the pressure or signal ranges.
Facts checked against Rotork plc company information and product data, October 2026.
Browse Rotork products by category: Valve Actuator, Regulators, Valve Positioner.
FAQ
Questions about the Rotork CVL-500 Linear Electric Control Valve
Answers from our engineering team on installation, compatibility and integration.
01What thrust and stroke does the Rotork CVL-500 provide?
The CVL-500 is rated at 500 lbf (2,224 N), settable down to 40 percent of that, over a maximum stroke of 1.5 in (38.1 mm), with a full-stroke time of 6 seconds at 100 percent speed.
02Does the CVL-500 need instrument air?
No. It is a fully electric actuator with an internal brushless DC motor and electronics, so it takes only a power supply and a 4 to 20 mA signal and needs no air supply or positioner.
03Which supply voltages can the CVL-500 run from?
AC units accept 100 to 240 VAC at 50 or 60 Hz through an internal switch-mode supply, and a 24 VDC option is available for this size; the DC option draws up to 7 A.
04What is the mounting pattern of the CVL-500?
The datasheet shows MSS SP-102 FA07 and ISO 5210 F07 references with four M8 x 1.25 holes, 18 mm deep, on a 70 mm PCD, with a 5/16 in UNC imperial alternative.
05Can the CVL-500 hold the valve if power fails?
It resists back-drive up to 125 percent of rated thrust as built, an optional solenoid lock extends this to 300 percent, and an optional super-capacitor reserve powerpack can drive it to a preset position on power loss.