Brand: Rotork
Rotork IQS12 Single-Phase Multi-Turn Electric Actuator
Description
Rotork IQS12 overview
The Rotork IQS12 is the single-phase version of the IQ multi-turn electric actuator, intended for sites where a three-phase supply is not available at the valve. Rotork’s IQS electrical data covers single-phase supplies of 110 to 120 V and 220 to 240 V at 50 Hz and 60 Hz, and for 220 to 240 V at 50 Hz the Rotork IQS12 is listed with a rated torque of up to 65 Nm (48 lbf.ft). The document that carries this data is now labelled legacy by Rotork, so the exact IQS12 designation matters when a replacement or spare unit is needed.
Despite the single-phase supply, the IQS12 keeps the IQ characteristics: a squirrel cage induction motor designed for valve duty, torque switch protection by direct measurement of output torque, and a sealed enclosure that holds the starter, local controls and terminals. Rotork states that the motor reaches full speed within 3 cycles of the mains frequency, about 60 ms at 50 Hz and 50 ms at 60 Hz.
This page is intended to help engineers and purchasers identify the IQS12 quickly, compare it with neighbouring sizes and prepare a clear enquiry. All figures come from Rotork’s own published electrical and specification documents, and where a value is not published we do not quote one.
Key features of the IQS12 actuator
- Single-phase operation, so the IQS12 can be fed where only a one-phase supply reaches the valve.
- Torque switch as the primary protection, measured directly at the output, with thermostats embedded in the motor.
- Stall protection limits torque to about 150 percent of rated when torque switch bypass is enabled, for no more than 5 seconds.
- Lost-motion drive lets the motor reach speed before the load is applied.
- Setting through non-intrusive infrared or Bluetooth communication, with the same IQ local controls and display.
- Rotork data covers 50 Hz and 60 Hz single-phase supplies in two voltage bands.
IQS12 technical specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rotork |
| Model | IQS12 |
| Range | IQS single-phase multi-turn electric actuator |
| Supply | Single-phase, 220 to 240 V, 50 Hz (data table); 110 to 120 V also published |
| Motor | Low inertia squirrel cage induction motor, TENV, class F insulation, class B temperature rise |
| Motor protection | Dual embedded thermostat (132 °C), stall limited to 5 seconds |
| Listed speeds (230 V, 50 Hz) | 18, 24, 36, 48, 72 and 96 rpm |
| Maximum rated torque | 65 Nm (48 lbf.ft) |
| Rated torque current at max torque row | 3 A |
| Starting / stall current at max torque row | 7.5 A |
| Source of electrical data | PUB002-119 |
IQS12 electrical and performance data
The table lists each output speed published for the IQS12 under single-phase 220 to 240 V at 50 Hz. Rotork compiles the values from averaged production test data, so use them for cable and protection sizing rather than as guaranteed unit values.
| Speed (rpm) | Poles | Rated torque (Nm) | Rated torque (lbf.ft) | Starting / stall current (A) | Rated torque current (A) | Average torque current (A) | Average power (kW) |
|---|---|---|---|---|---|---|---|
| 18 | 4 | 65 | 48 | 7.5 | 3 | 2.2 | 0.4 |
| 24 | 4 | 60 | 44 | 7.5 | 3 | 2.2 | 0.42 |
| 36 | 4 | 45 | 33 | 7.5 | 3 | 2.2 | 0.42 |
| 48 | 4 | 40 | 30 | 7.5 | 3 | 2.2 | 0.35 |
| 72 | 4 | 30 | 22 | 7.5 | 3 | 2.2 | 0.35 |
| 96 | 4 | 25 | 18 | 7.5 | 3 | 2.2 | 0.35 |
Single-phase 60 Hz builds of the IQS12 are listed at different output speeds from the 50 Hz ones, so always state the mains frequency when you enquire.
Typical applications in Oman and the GCC
In oil and gas facilities in Oman, the IQS12 is specified on isolation and control valves in gathering stations, pipelines and tank farms, where an actuator with integral controls and a lockable local/stop/remote selector simplifies operations. Utilities and power plants use similar IQS actuators on cooling water, feedwater and fuel lines. Water and desalination operators across the GCC rely on them for intake, transfer and distribution valves, where the sealed enclosure copes with humidity and dust. In manufacturing and petrochemical sites the IQS12 appears on process utilities and skid packages. Because the actuators are described by Rotork as suitable for indoor and outdoor use, with ambient limits of minus 30 to plus 70 degrees Celsius in the IQ specification, they suit the hot coastal climate of Muscat, Sohar and Duqm.
Typical valve types include gate and globe valves for multi-turn actuators and ball, plug and butterfly valves for part-turn actuators, so confirm the valve stem or shaft details when you request the IQS12.
Selection and compatibility notes for the IQS12
When choosing a supply for the IQS12, note that single-phase starting currents are high compared with the rated torque current, so cable and protection sizing should use the starting or stall column of the table. Rotork does not normally recommend frequency converters for IQS actuators, and a UPS used for backup operation should output a true sine wave with negligible harmonic distortion. The figures are averages from production test data and individual test certificates are available on request.
A short guide to reading the Rotork electrical data helps when comparing builds. Rated torque is the catalogued torque output at full load and represents a torque switch setting of 100 percent. The starting or stall figure is the current drawn when the output starts to move or when the motor is stalled; standard protection limits torque to about 150 percent of rated when torque switch bypass is enabled, and stall is limited to a maximum of 5 seconds. Rated torque current is the average current at the catalogue torque. Average, or nominal, torque corresponds to approximately one third of the rated catalogued torque, and the last columns of the table show current and power at that load. The single-phase motor is a low inertia squirrel cage induction design with a totally enclosed non-ventilated housing, class F insulation, class B temperature rise, dual embedded thermostats at 132 °C and sealed bearings lubricated for life. The data is averaged from production test results for actuators of the same size, speed and voltage, and the document states that individual test certificates give unit specific loadings.
Match the IQS12 to the valve by the maximum valve torque including a safety margin, the stroke or number of turns, the mounting flange and the required operating time. Rotork’s sizing guidance says the actuator must guarantee valve closure at the specified differential pressure and temperature, with enough margin that the torque switch can still trip at maximum valve torque when the supply is 10 percent below nominal. Mention any hazardous-area, SIL or fieldbus requirement in your enquiry, because the certification of an actuator depends on the exact build.
Installation and commissioning
Confirm that the supply feeding the IQS12 is single-phase at the required voltage band and that the cable is sized against the starting current. Fit the drive coupling to the valve stem, wire the supply and control terminals, and use the Rotork setting tool to define the limits and torque thresholds. The local selector can be locked in local, stop or remote positions to prevent accidental operation.
Rotork supplies a commissioning kit with its actuators comprising an installation manual, wiring diagram and cover seals. Keep the terminal compartment dry during cabling, and torque the cover fasteners evenly after wiring so the IQS12 retains its enclosure rating.
Maintenance and spare parts for the IQS12
Rotork designs the gear case as an oil-filled enclosure suitable for operation at any angle, and the motor and internal electrical elements are sealed from the environment, so routine maintenance on the IQS12 is mainly visual and functional. Check the cable glands, cover seals and fasteners during shutdowns, exercise infrequently used valves, and review the datalogger or event records for torque trends that point to valve wear. Replace seals if covers were opened. For hard-to-find parts and replacement units please send the full nameplate details together with the model IQS12.
FAQ summary
The most common questions we receive about the IQS12 concern its torque rating, available output speeds, supply voltage options, and how to specify a replacement. In short, the IQS12 is a Rotork single-phase multi-turn electric valve actuator; the data on this page is taken from the Rotork documents listed below; and the exact build always depends on the voltage, speed and options that you confirm in your RFQ. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
The datasheet for the IQS12 is the Rotork electrical data document PUB002-119, which you can download from this page when available. To obtain pricing and lead time, send the RFQ with the part number IQS12, the quantity, supply voltage and frequency, valve type and any special requirements, and our team will respond promptly. Please note that the product is described by its model designation and that final configuration is confirmed against the manufacturer’s data.
Datasheets & Documents
- Datasheet Rotork IQS12 Single-Phase Multi-Turn Electric Actuator Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rotork is a British flow control company best known for electric valve actuators. Jeremy Fry founded Rotork Engineering Company in Bath in 1957, the year its first actuator, the 100A, went on sale, and the group is still headquartered in Bath and listed on the London Stock Exchange. Today Rotork makes electric, pneumatic, hydraulic and electro-hydraulic actuators, gearboxes, precision regulators and valve positioners.
Seven Star LLC is an independent supplier listing Rotork actuators, Rotork Fairchild regulators, YTC positioners and spare parts for buyers in Oman and the GCC. Replacement units are matched from the actuator nameplate and wiring diagram number.
Rotork company profile
| Origin | Founded by Jeremy Fry in 1957 in Bath, England; first product the 100A valve actuator |
|---|---|
| Headquarters | Brassmill Lane, Bath, United Kingdom |
| Ownership | Rotork plc, a public company listed on the London Stock Exchange |
| Acquired brands | Fairchild precision pneumatic controls (2011, Winston-Salem, USA), YTC valve positioners (Young Tech Co., Seoul, 2014), Mastergear gearboxes (2016) |
| Product families | Intelligent electric actuators, control valve actuators, electro-hydraulic and fluid power actuators, gearboxes, precision regulators, positioners and network control systems |
Milestones
- 1957: Jeremy Fry founds Rotork in Bath, England; the first product is the 100A valve actuator.
- 2011: Fairchild precision pneumatic controls (Winston-Salem, USA) is acquired.
- 2014: YTC valve positioners (Young Tech Co., Seoul) is acquired.
- 2016: Mastergear gearboxes is acquired.
Rotork actuators, regulators and positioners
| Series | Type | Typical use |
|---|---|---|
| IQ3 | Intelligent multi-turn electric actuator | Gate and globe valves, penstocks and sluice gates; non-intrusive setup with a Bluetooth setting tool, double-sealed enclosure, data logging |
| IQT3 | Intelligent part-turn electric actuator | Ball, butterfly and plug valves and dampers, with the same setup and diagnostics as IQ3 |
| CVA | Precision control valve electric actuator | Continuous modulating control of linear and part-turn control valves where instrument air is not available |
| CMA | Compact modulating electric actuator | Small control valves, chemical injection and metering pumps |
| Skilmatic SI3 | Self-contained electro-hydraulic actuator | Spring-return fail-safe and ESD duty with partial stroke testing, needing only an electrical supply |
| GP / GH | Scotch yoke pneumatic (GP) and hydraulic (GH) actuators | Large quarter-turn valves on pipelines and ESD service; spring-return or double-acting |
| CP | Compact pneumatic quarter-turn actuator | Smaller on-off ball and butterfly valves on plant air |
| Fairchild 10, 30, 55, 66, M11, 81 | Precision pressure regulators | Instrument air to positioners and actuators, test benches; Model 66 in stainless steel for corrosive and offshore sites |
| Fairchild 1000 | No-bleed precision regulator | Saves instrument air or gas where continuous bleed is not acceptable |
| Fairchild 10BP, 4000ABP | Back pressure regulators | Holding upstream pressure in process and test systems |
| YTC YT-1000, YT-3300 | Valve positioners | Electro-pneumatic (YT-1000) and smart HART (YT-3300) positioning of linear and rotary pneumatic actuators |
Where Rotork equipment is used
Rotork actuators are common on oil and gas pipelines and terminals, refineries and gas plants, water and wastewater networks, desalination plants and power stations. Electric IQ actuators handle isolation valves on long pipelines and water mains, often networked over Rotork Pakscan, Modbus or another fieldbus. Skilmatic and scotch yoke actuators cover emergency shutdown valves, and Fairchild regulators and YTC positioners sit on pneumatic control valves throughout process plants.
Ordering Rotork actuators and spare parts: what we need
Send photos of the actuator nameplate with the model, serial number and wiring diagram number; the wiring diagram is usually inside the terminal cover. Rotork can identify the original build, including options and control interface, from the serial number. For a new application add the valve type and size, required torque or thrust, operating time, mounting flange (ISO 5210 or ISO 5211), power supply, control signal or network protocol, fail-safe requirement and hazardous-area marking. For regulators and positioners send the full model code and the pressure or signal ranges.
Facts checked against Rotork plc company information and product data, October 2026.
Browse Rotork products by category: Valve Actuator, Regulators, Valve Positioner.
FAQ
Questions about the Rotork IQS12 Single-Phase Multi-Turn Electric
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum rated torque of the Rotork IQS12?
In the Rotork electrical data for single-phase 220 to 240 V at 50 Hz, the IQS12 is listed with a maximum rated torque of 65 Nm (48 lbf.ft) at its 18 rpm build, and a lowest listed torque of 25 Nm at the fastest speed shown.
02Which output speeds are listed for the IQS12?
The data table for single-phase 220 to 240 V at 50 Hz lists 18, 24, 36, 48, 72 and 96 rpm for the IQS12. Other speeds, supply voltages or options may exist, so confirm the exact build in your RFQ.
03What current does the IQS12 draw at rated torque?
For the 18 rpm build under single-phase 220 to 240 V at 50 Hz, Rotork lists a rated torque current of 3 A and a starting or stall current of 7.5 A. Individual production test certificates are available from the manufacturer for exact unit values.
04Can the IQS12 be set up without opening the covers?
Rotork describes setting of torque levels, position limits and indication contacts for the IQ family over an infrared or Bluetooth wireless interface, without removing the actuator covers and, where needed, without mains power.
05How do I request a quotation for the IQS12?
Send the part number IQS12 with quantity, speed, supply voltage, valve details and any hazardous-area or network needs, and we will answer your RFQ. Seven Star LLC is an independent supplier and is not affiliated with Rotork.


















Reviews