Brand: MTL (Eaton)
MTL MTL5546 4-20 mA HART Isolating Driver with LFD
Description
MTL5546 overview
The MTL5546 takes a floating 4/20 mA signal from a safe-area controller and uses it to drive a current/pressure converter, valve positioner or other load of up to 800 ohm in the hazardous area. For HART positioners the module allows digital communication in both directions, and it lets a controller with read-back detect open and short circuits in the field wiring.
The MTL5546 is part of the MTL5500 range of DIN-rail mounted intrinsically safe isolators from MTL, a brand of Eaton. As a single-channel module, it is a isolating driver for hart valve positioners that clips onto a standard 35 mm rail, with plug-in terminals for the hazardous-area and safe-area wiring. Because many MTL5500 numbers look alike, this page repeats the facts taken from the manufacturer datasheet so that engineers can confirm that the MTL5546 matches their loop before sending an enquiry.
Key features of the MTL MTL5546
- Drives loads up to 800 ohm (16 V at 20 mA) in the hazardous area
- Passes bi-directional HART signals for smart valve positioners
- Line fault detection: the current taken drops to a preset level on an open or short circuit
- Over range to 24 mA for loads up to 520 ohm
- SIL2 capable for a single device and SIL3 capable with a redundant (HFT=1) arrangement
- Fully galvanic isolation: 250 V rms between safe-area and hazardous-area terminals, and 250 V rms between safe-area circuits and the power supply
- Powered from 20 to 35 V dc, with an optional Powerbus system to share the supply across a row of modules
MTL5546 technical specifications
| Parameter | Value |
|---|---|
| Model | MTL5546 |
| Range | MTL5500 DIN-rail isolators |
| Supply voltage | 20 to 35 V dc |
| Isolation | 250 V rms tested at 1500 V rms minimum between safe and hazardous terminals; 250 V rms between safe-area circuits and supply |
| Terminals | accept conductors up to 2.5 mm squared, stranded or single-core |
| Mounting | 35 mm T-section DIN rail (7.5 or 15 mm) to EN 50022 |
| Ambient temperature | minus 20 to plus 60 C operating; minus 40 to plus 80 C storage |
| Humidity | 5 to 95 percent relative humidity |
| Weight | approximately 150 g |
| EMC | to EN 61326 and NE21 |
| Location of module | safe area |
| Number of channels | One |
| Maximum load resistance | 800 ohm (16 V at 20 mA) |
| Minimum load resistance | 90 ohm (short-circuit detection at less than 50 ohm) |
| Over range | 24 mA (load up to 520 ohm) |
| Input and output ripple | less than 40 microamps peak to peak |
| Response | settles within 200 microamps of final value within 100 ms |
| Input voltage, normal field wiring | less than 6.0 V |
| Input current, open circuit | less than 0.9 mA |
| Input current, short circuit | less than 0.9 mA |
| Safety description | Uo 28 V, Io 93 mA, Po 651 mW, Um 253 V rms or dc |
| Functional safety | SIL2 capable single device (HFT=0); SIL3 capable HFT=1 |
The module must be installed in the safe area, while the field device it serves may be located as the datasheet allows: Zone 0, IIC, T4 to T6 hazardous area where the connected device is suitably certified, or a Division 1, Group A hazardous location. Always read the current approval certificate on the manufacturer website for entity parameters, since the datasheet states that safety approvals can be revised.
Typical applications of the MTL5546 in Oman and the GCC
The manufacturer describes the MTL5546 as a isolating driver for a hazardous-area current-to-pressure converter or HART valve positioner. In Gulf plants this duty usually means control-valve positioners and I/P converters on wellhead, separator, compressor and pipeline valves that must be driven from a DCS output card across an intrinsic safety barrier.
- Oil and gas: wellsites, gathering stations, gas plants and pipeline terminals
- Utilities and power: turbine skids, fuel gas systems and boiler auxiliaries
- Water and desalination: chemical dosing, treatment and pumping areas with flammable vapour risk
- Petrochemical and manufacturing: solvent storage, loading bays and process units
Many older Gulf installations carry MTL5000 or MTL4000 series isolators. The datasheet states that the MTL5500 can replace MTL5000 units, so the MTL5546 is often requested as a like-for-like spare during shutdowns.
Selection and compatibility notes for the MTL5546
The MTL5546Y is very similar but provides open-circuit detection only, with no short-circuit detection, and an open-circuit input current of less than 0.5 mA. For two channels in one housing look at the MTL5549 family. Choose the version whose line-fault behaviour matches the input card of your control system.
Check the certificate of the field device against the safety description of the MTL5546: the field device must tolerate the module output parameters, and the cable capacitance and inductance must stay within the permitted limits. The maximum safe-area voltage Um for the range is 253 V rms or dc.
Installation and commissioning of the MTL5546
Clip the module onto the DIN rail and fit the supplied connectors. The hazardous-area plugs are the blue-labelled terminals, and the safe-area plugs and the power connector are separate parts. When crimp ferrules are used, the manufacturer recommends a metal tube length of 12 mm and a wire trim length of 14 mm. Keep intrinsically safe wiring segregated from other wiring as required by the installation code, and record the loop tag on the optional TH5000 tag holder. Check the supply is within 20 to 35 V dc before energising, and verify the loop with the module fitted before connecting the field cable.
Maintenance and spare parts
An isolator has no user-serviceable parts. Routine checks are limited to terminal tightness, LED status, supply voltage and a periodic loop test according to the plant procedure. A failed module should be replaced as a whole, and the plug-in connectors can be moved to the replacement. Related accessories listed in the datasheet include the HAZ and SAF connector plugs, the PWR5000 power connector, the PB-8T, PB-16T, PB-24T and PB-32T Powerbus kits and the THR2 rail.
Related products and ordering notes for the MTL5546
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The MTL5500 range is the DIN-rail version of the family and the MTL4500 range is the backplane-mounted version, so quote the exact number MTL5546 when ordering, and mention any suffix, because a letter such as S, A, B, C, D or Y changes the function.
MTL5546 FAQ summary
Typical questions concern the function, the safety description and the supply of the MTL5546. It is a isolating driver for a hazardous-area current-to-pressure converter or HART valve positioner, powered from 20 to 35 V dc, with the figures listed in the table above.
Documents and quotation
The range datasheet for the MTL5546 is attached to this page. To request a quotation, send an RFQ with the part number MTL5546, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.
Other Models in the MTL5500 Range
Seven Star LLC supplies models from the MTL5500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| MTL MTL5544 2-Channel HART Repeater Power Supply | Isolator & Barrier | View details |
| MTL MTL5546 4-20 mA HART Isolating Driver with LFD | Isolator & Barrier | You are viewing this model |
| MTL MTL5501-SR Fail-Safe Switch Interface with LFD, SIL3 | Isolator & Barrier | View details |
| MTL MTL5510 4-Channel Switch/Proximity Interface, Solid-State | Isolator & Barrier | View details |
| MTL MTL5511 1-Channel Switch/Proximity Interface, Relay + LFD | Isolator & Barrier | View details |
| MTL MTL5513 2-Channel Switch/Proximity Interface, Solid-State | Isolator & Barrier | View details |
| MTL MTL5514 1-Channel Switch/Proximity Interface, LFD Relay | Isolator & Barrier | View details |
| MTL MTL5516C 2-Channel Switch/Proximity Interface, Relay + LFD | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet MTL MTL5546 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.
Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.
MTL (Eaton) company profile
| Founded | 1971, Luton, England, as Measurement Technology Ltd |
|---|---|
| Origin | Spin-off from Kent Instrumentation |
| Headquarters | Luton, England |
| Ownership | Eaton (Crouse-Hinds), via Cooper Industries from 2008 |
| Product families | MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points |
Milestones
- 1971: Measurement Technology Ltd is founded in Luton.
- 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
- 2008: Cooper Industries acquires MTL Instruments for £144 million.
- 2012: Eaton acquires Cooper Industries.
MTL product families listed here
Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.
Where MTL barriers and isolators are used
These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.
MTL (Eaton) products we list
Ordering MTL modules: what we need
Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.
Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.
Browse MTL (Eaton) products by category: Isolator & Barrier, Automation Software.
FAQ
Questions about the MTL MTL5546 4-20 mA HART Isolating Driver with LFD
Answers from our engineering team on installation, compatibility and integration.
01What is the MTL5546 used for?
The datasheet describes the MTL5546 as a isolating driver for a hazardous-area current-to-pressure converter or HART valve positioner.
02What supply does the MTL5546 need?
It is powered from 20 to 35 V dc and is installed in the safe area, with 250 V rms isolation between the safe-area circuits and the supply.
03How is the MTL5546 mounted?
It clips onto a 35 mm T-section DIN rail and uses plug-in terminals that accept conductors up to 2.5 mm squared.
04Can the MTL5546 replace an older MTL5000 module?
The manufacturer states that the MTL5500 range can replace MTL5000 units, but check the function, suffix and certificate before ordering.
05How do I request a quotation for the MTL5546?
Send an RFQ with the part number MTL5546, quantity and delivery location in Oman or the GCC, and we will reply with availability and lead time.