- Automation & ControlView all 2,760 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: MICHELL Instruments
Michell XP-LQ Easidew PRO XP Moisture-in-Liquids Transmitter
Description
Michell XP-LQ overview: explosion-proof moisture transmitter for liquids
Michell XP-LQ is the parent order code of the Easidew PRO XP for liquids. It is the liquid-service version of the Michell explosion-proof moisture transmitter and measures dissolved moisture in non-polar liquids, reporting moisture content in ppmW as a two-wire 4-20 mA signal.
The datasheet gives a capability of 0 to 1000 ppmW, factory configured to the customer range and application. The transmitter needs saturation constants for the liquid being measured; a six-point look-up table covers the range from 0 to plus 50 degrees Celsius, and constants for eight common liquids can be loaded through the application software, or entered manually.
Buyers in refining, petrochemicals and gas processing use the Michell XP-LQ code when they must monitor water in hydrocarbon liquids such as propane, butane or toluene, where free water can damage catalysts or cause freezing in cold sections.
The image shows the stainless steel housing version of the Easidew PRO XP transmitter from the manufacturer datasheet; the XP-LQ shares this mechanical design with the gas version.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list XP-LQ so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of XP-LQ
- Moisture in liquids capability of 0 to 1000 ppmW, factory configured for the customer liquid and range.
- Programmable saturation constants, with a six-point look-up table for 0 to plus 50 degrees Celsius and stored constants for eight common liquids.
- Same flameproof housing family as the gas version: ATEX, UKCA, IECEx and cQPSus certification, IP66 and NEMA 4.
- Two-wire 4-20 mA output with factory fault levels of 23 mA, 4 mA and 20 mA.
- Process pressure rating of 450 barg and a 3/4 inch 16 UNF process connection with Viton or Kalrez O-ring.
- Flow guidance for liquids of 0.1 to 0.3 L/min through the sample block or 0.1 to 1 m/s with direct insertion.
XP-LQ technical specifications
The table below lists values published by the manufacturer for the product family of XP-LQ. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | XP-LQ, Easidew PRO XP for liquids |
| Measurement | Moisture content in liquids, ppmW |
| Range | 0 to 1000 ppmW capability, configured to customer range and application |
| Output | 4-20 mA, two-wire, current source |
| Supply voltage | 14 to 28 V DC |
| Saturation constants | Six-point look-up table up to 1000 ppmW over 0 to plus 50 degC; constants for 8 common liquids can be programmed |
| Operating temperature | Minus 40 to plus 60 degC |
| Operating pressure | 45 MPa (450 barg) maximum |
| Flow rate | 0.1 to 0.3 L/min through sample block; 0.1 to 1 m/s direct insertion |
| Ingress protection | IP66; NEMA 4 |
| Process connection | 3/4 inch 16 UNF, 316 stainless steel; O-ring Viton or Kalrez for aromatic service |
| Electrical connection | Dual 3/4 inch NPT gland |
| Weight | Aluminium 1.6 kg; 316 stainless steel 2.4 kg |
Typical applications of XP-LQ in Oman and the GCC
- Water in hydrocarbon liquids such as propane, butane and pentane streams.
- Petrochemical process liquids and polymer feedstocks.
- Catalyst protection in refinery units.
- Moisture monitoring in aromatic solvents such as toluene, with the Kalrez O-ring option.
In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as XP-LQ is usually specified against a defined dew-point or ppmV target and a documented calibration.
Selection and compatibility notes
The XP-LQ configuration string covers display, guard, sample block, bracket, housing, liquid type and O-ring. The liquid list on the order-code sheet names methane, propane, ethane, propylene, ethylene, butane, isobutane, pentane, toluene and cyclopentane, plus a user-defined option, and the ppmW range is stated at the time of order.
Material certificates XP-LQ-M1 (BS EN 10204 type 3.1) and XP-LQ-M2 (type 3.1 plus NACE conformity) are ordered as separate lines.
Confirm four things before ordering XP-LQ: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.
Installation and commissioning of XP-LQ
Measurement of moisture in liquids depends on a representative, flowing liquid sample at a known temperature, so provide a sample block with the flow stated by the manufacturer and keep the liquid free of gas pockets around the sensor.
Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.
Maintenance, calibration and service
Recalibration and service exchange are listed for the PRO XP liquids version under the XP-LQ-X family code, and the order-code sheet lists XP-RECAL for recalibration with a traceable certificate.
Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.
Related products and ordering notes for XP-LQ
- EA-XP: Easidew PRO XP for gases, same housing and approvals.
- XP-DIS-RK: replacement display module kit for the Easidew PRO XP.
- EPR-LQ-IS: intrinsically safe moisture-in-liquids transmitter from the Easidew PRO I.S. family.
When you request XP-LQ, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about XP-LQ
- What is XP-LQ? XP-LQ is the manufacturer parent order code for the Easidew PRO XP explosion-proof moisture transmitter for liquids, reporting moisture content in ppmW.
- What does XP-LQ suit? It suits moisture monitoring in non-polar process liquids in hazardous areas, such as light hydrocarbons and aromatics.
- Does XP-LQ need liquid-specific setup? Yes. The transmitter needs saturation constants for the liquid being measured; the manufacturer lists a look-up table and stored constants for eight common liquids, and the liquid is chosen in the order code.
- What should I send with an RFQ for XP-LQ? Send the part number XP-LQ, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of XP-LQ and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number XP-LQ, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for XP-LQ in writing.
Other Models in the Michell Easidew Pro Xp Range
Seven Star LLC supplies models from the Michell Easidew Pro Xp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell EA-XP Easidew PRO XP Explosion-Proof Dew-Point Transmitter | Humidity & Dew Point Instruments | View details |
| Michell XP-LQ Easidew PRO XP Moisture-in-Liquids Transmitter | Humidity & Dew Point Instruments | You are viewing this model |
| Michell XP-DIS-RK Easidew PRO XP Replacement Display Module Kit | Humidity & Dew Point Instruments | View details |
Datasheets & Documents
- Datasheet Michell XP-LQ Easidew PRO XP Moisture-in-Liquids Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell XP-LQ Easidew PRO XP Moisture-in-Liquids
Answers from our engineering team on installation, compatibility and integration.
01What is XP-LQ?
XP-LQ is the manufacturer parent order code for the Easidew PRO XP explosion-proof moisture transmitter for liquids, reporting moisture content in ppmW.
02What does XP-LQ suit?
It suits moisture monitoring in non-polar process liquids in hazardous areas, such as light hydrocarbons and aromatics.
03Does XP-LQ need liquid-specific setup?
Yes. The transmitter needs saturation constants for the liquid being measured; the manufacturer lists a look-up table and stored constants for eight common liquids, and the liquid is chosen in the order code.
04Can Seven Star LLC supply XP-LQ in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for XP-LQ?
Send the part number XP-LQ, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.


















Reviews
There are no reviews yet.