Brand:

Magnetrol Modulevel P68 Side-Mounted Float Controller

Description

Overview

A narrow level span does not need a long displacer. The Magnetrol Modulevel P68 is the side-mounted float version of the Modulevel pneumatic controller and is the member of the family picked for short measuring ranges. It mounts on the side of a vessel in a carbon steel body with either a 3 inch NPT threaded connection or a 4 inch flange, and the float movement drives the same pneumatic controller head used across the range.

The magnetic coupling, range spring and flapper-nozzle relay inside the head turn float travel into an output air pressure, with a 4 to 1 amplification from the pilot relay to quicken valve response.

Seven Star LLC is an independent supplier serving Oman and the GCC. We can quote this model on request with the connection and control mode you need.

Pressure and mounting limits of Magnetrol Modulevel P68

This is the point where the P68 stands apart: its rating is suitable for up to 800 psig at 100 degrees Fahrenheit (55 bar at 38 degrees Celsius), well below the 4047 psig of the high pressure cage models. Check the operating pressure of the vessel before choosing it, and use a P6x cage model if the pressure is higher.

The catalogue describes it as ideally suited for narrow level range applications, which suits separators, drip pots and small receivers where the process liquid moves only a few inches between alarm and control points.

Magnetrol Modulevel P68 data table

Parameter Value
Process pressure (standard models) Up to 4047 psig at 100 degrees Fahrenheit (279 bar at 38 degrees Celsius)
Temperature, stainless steel cage Minus 150 to plus 700 degrees Fahrenheit (minus 101 to plus 371 degrees Celsius)
Temperature, carbon steel cage Minus 20 to plus 700 degrees Fahrenheit (minus 29 to plus 371 degrees Celsius)
Specific gravity range 0.11 minimum to 2.20 maximum
Interface detection Minimum 0.10 specific gravity difference between liquids
Output signal 3 to 15 or 6 to 30 psig (proportional and transmitter); 0 to 20 or 0 to 35 psig (differential gap)
Supply pressure Up to 250 psig to the regulator, instrument quality air, regulator set 5 psig above maximum output
Air consumption 3 SCFH at 9 psig output; 6 SCFH at 15 psig output
Response 100 cubic inches of output volume in 3.2 seconds for a 3 to 15 psig rise
Level range Fractional inches up to 10 feet (3 m), limited by displacer length
Wetted parts 316 SS displacer, 304 or 316 SS trim, 316 SS or Inconel spring, carbon steel or 316 SS chamber
Housing IP53 (IP55 on request), NEMA 1, 2, 3 and 3R
Control action Direct or reverse
Mounting Side-mounted float model, carbon steel body
Process connection 3 inch NPT threaded or 4 inch flanged
Pressure limit for this model 800 psig at 100 degrees Fahrenheit (55 bar at 38 degrees Celsius)

Where the P68 is used

Typical Modulevel duties from the catalogue include feedwater heater regulation, drip pot condensate level control, flash tank level transmission, vent gas scrubber control and boiler level control. In the Gulf region the P68 fits steam condensate systems in power and desalination plants and small separators in gas facilities, where only a limited span has to be controlled and a simple pneumatic loop is preferred to electronics.

The built-in visual level indicator is independent of the air supply, so operators can read the level even when instrument air is lost. That feature is useful during start-up and in plants where operators make regular rounds, because the percentage of span can be read at the head without any instrument or laptop. Many sites also add the optional high-low electronic alarm signal, which gives an inexpensive backup alarm that works on a separate principle from the pneumatic loop.

Choosing control mode

  • Proportional for holding level within a band using a control valve.
  • Transmitter for a 100 percent span signal to a receiver or indicator.
  • Proportional plus integral where offset must be eliminated.
  • Differential gap for on-off control between two switching points.
  • Optional high-low electronic alarm signal as a backup alarm.

Installation

Thread the body into a 3 inch NPT nozzle or bolt up the 4 inch flange, keeping the unit level so that the float moves freely. Supply filtered air with the regulator set 5 psig above maximum output, and connect the output to the valve. The head rotates through 360 degrees, which simplifies piping.

Optional filter regulator 06-9501-002 and gauge 06-9501-003 can be ordered as separate items. Make sure the air line is clean and dry, as moisture and oil are the most common causes of drifting output in pneumatic instruments.

Comparing float and displacer designs

A displacer sees a change in buoyant force as the liquid rises along its length, which gives a smooth proportional signal over a long span. A float, in contrast, follows the surface and suits short strokes. The P68 uses the float principle with the same magnetic coupling used for the displacer models, so the head, the calibration steps and the control modes are shared with the rest of the family, and a technician who knows one will understand the other.

Because the body is carbon steel and the nominal pressure is limited to 800 psig at 100 degrees Fahrenheit, the P68 is generally selected for clean, moderate pressure services. If the liquid is corrosive or the pressure is higher, ask us about the stainless steel cage models in the same catalogue. When quoting, tell us the connection type, the liquid and its specific gravity, the span between control points and the control mode so we can check the configuration with you.

Maintenance

Inspect and clean the float periodically, drain the air filter, and check the zero and span at shutdowns. The head can be removed for service without breaking the process boundary.

Related items you may also need: Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon Steel Flange | Magnetrol Z31-2849-002 Fieldbus Electronic Module for Eclipse 706 GWR | Magnetrol Z30-9166-004 Fieldbus Wiring Board for Pulsar R86, | All Magnetrol products.

Magnetrol Modulevel P68 ordering checklist

  • When the Magnetrol Modulevel P68 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Magnetrol Modulevel P68 is answered with a written confirmation of the code, condition and expected lead time.
  • Use the attached datasheet to check the Magnetrol Modulevel P68 ratings, dimensions and connection details against your drawings.
  • We supply the Magnetrol Modulevel P68 as part of our level switches range to plants in Oman and the GCC.
  • For critical duty, keeping one Magnetrol Modulevel P68 as a site spare shortens downtime after a failure.

Documents and quotation

The Magnetrol catalogue 48-110 is provided as the datasheet for the Magnetrol Modulevel P68. Send your RFQ with the part number Magnetrol Modulevel P68, the connection size and the control mode, and we will reply with availability and lead time for Oman and the GCC.

Other Models in the Modulevel Range

Seven Star LLC supplies models from the Modulevel range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol Modulevel P65 Pneumatic Level ControllerLevel SwitchesView details
Magnetrol Modulevel P51 Flanged Top Level ControllerLevel SwitchesView details
Magnetrol Modulevel P68 Side-Mounted Float ControllerLevel SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Magnetrol Modulevel P68 Side-Mounted Float Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Modulevel P68 Side-Mounted Float

Answers from our engineering team on installation, compatibility and integration.

01What connections does the Magnetrol Modulevel P68 offer?
The carbon steel side-mounted float model is available with a 3 inch NPT threaded body or a 4 inch flanged connection.
02What pressure is the Modulevel P68 rated for?
The catalogue states it is suitable for pressures up to 800 psig at 100 degrees Fahrenheit (55 bar at 38 degrees Celsius).
03When should the Modulevel P68 be selected?
It is intended for narrow level range applications, where a long displacer and external cage are not required.
04Does the Modulevel P68 need electrical power?
The pneumatic controller works with instrument air, and the built-in visual indicator does not depend on the air supply.
05What air consumption does the Modulevel P68 head have?
The catalogue gives 3 SCFH at 9 psig output and 6 SCFH at 15 psig output, with 100 cubic inches delivered in 3.2 seconds.