Brand: Magnetrol
Magnetrol Tuffy Pneumatic Side-Mounted Float Switch
Description
Overview
Where there is no electrical power or where electrical equipment is simply unwelcome, a float switch that talks in air pressure is the practical answer. The Magnetrol Tuffy Pneumatic liquid level switch is a side-mounted float switch whose single pneumatic switch mechanism opens, closes or diverts an instrument air signal when the liquid reaches a set height. It threads or flanges into a tank or vessel through a 2 inch NPT connection and is built with 316 stainless steel wetted parts.
The switching action relies on a magnet attached to the float and a separate switching mechanism, split by a non-magnetic pressure-tight barrier. When the float rises or falls, the magnet moves the pivot arm of a spring valve plunger, and the pneumatic ports change state. Nothing in the process touches the switch, which is why the unit keeps working in sour or dirty service.
Seven Star LLC is an independent supplier serving Oman and the GCC. Operators of day tanks, separators and process vessels can ask us to quote this switch with the cage and flange option they need.
Principle of operation in plain terms
Three ports, each with a quarter inch NPT thread, serve the valve. On the 3-way version, the normally open arrangement connects port A as inlet, port B as exhaust and port C as outlet, while the normally closed arrangement swaps the inlet and exhaust. A diverter version feeds port C as the inlet and distributes it to A and B, and a selector version takes inlets on A and B for a common outlet. A 2-way version drops one port by plugging it. The catalogue notes that port orientation may vary from unit to unit, so verify the markings before piping.
Because the switch is mechanical, the response is as fast as the float and the spring valve can move, and the unit needs only clean, dry instrument air to the supply port.
Magnetrol Tuffy Pneumatic specifications
| Parameter | Value |
|---|---|
| Switch action | Single pneumatic switch mechanism, high or low level alarm or control |
| Mounting | Horizontal, 2 inch NPT (threaded) or flanged |
| Wetted parts | 316/316L stainless steel, including NACE and ASME B31.3 construction |
| Housing | 316 stainless steel |
| Process temperature | Minus 40 to plus 300 degrees Fahrenheit (minus 40 to plus 149 degrees Celsius) |
| Pressure, 0.60 SG | 1500 psig at 300 degrees Fahrenheit (103 bar at 149 degrees Celsius) |
| Pressure, 0.40 SG | 500 psig at 300 degrees Fahrenheit (34 bar at 149 degrees Celsius) |
| Cage pressure (optional) | Up to 2200 psig (151 bar); Schedule 40 or 80 cage 1200 psig at 300 degrees Fahrenheit |
| Specific gravity | 0.60 minimum or 0.40 minimum |
| Supply pressure | Vacuum to 200 psig (13.8 bar) maximum |
| Maximum leakage | 0.5 SCFH at 100 psig (0.015 SCMH at 6.9 bar) |
| Minimum air flow | 2.0 SCFM at 100 psig (0.06 SCMM at 6.9 bar) |
| Ambient temperature | Maximum 100 degrees Fahrenheit (38 degrees Celsius) at maximum process temperature |
| Float size | 2.00 in diameter x 5.12 in (SG 0.4) or 4.57 in (SG 0.6) long |
How Magnetrol Tuffy Pneumatic differs from other Tuffy models
The electric Tuffy II uses an electrical switch and therefore needs wiring and a suitable enclosure. The pneumatic edition replaces the electrical head with an air valve, so it is the one to specify for service where there is no power or where compressed air is the control medium. Its pressure rating depends on the float: 1500 psig for a 0.60 minimum specific gravity and 500 psig for a 0.40 minimum. The cage version can be rated to 2200 psig when a high pressure chamber is ordered.
Typical applications
The catalogue lists sour service to NACE, high and low alarm, day storage tanks, clean liquids and process vessels. In Oman that includes wellhead separators and knock-out pots on remote sites, fuel day tanks for generators and pumps, chemical injection tanks and compressor suction scrubbers, where a pneumatic alarm can trip a shutdown valve or a pilot without electrical certification.
For hydrocarbon service, sour or not, the 316 stainless steel construction and optional NACE or ASME B31.3 cage are the main reasons to select this model. Clean liquids are best, because dirt or magnetic particles can foul the float.
Selection and ordering notes
- Choose the specific gravity code: 0 for a minimum of 0.60 and 1500 psi, or 4 for a minimum of 0.40 and 500 psi.
- Decide whether to mount directly through the 2 inch NPT connection or to add an external cage with two 1 inch NPT connections.
- Specify ANSI flanges when the vessel nozzle is flanged. The square flange part number 04-6804-001 is rated 250 psig at 400 degrees Fahrenheit (17 bar at 204 degrees Celsius).
- For NACE or ASME B31.3 cages with two 1 inch NPT connections, consult the factory.
- Add the filter regulator and safety check valve in the air line according to your design.
Installation and commissioning
Mount the switch horizontally with the float free to travel, leaving the stated clearance of 3.75 inches below the float. Pipe the supply to the correct port and fit a shut-off valve, a safety check valve and a drain in the air line. Cycle the level slowly and watch the air outlet change state at the rising and falling actuation levels. Keep the ambient temperature below 100 degrees Fahrenheit at maximum process temperature.
Use clean, dry instrument air, and do not exceed 200 psig at the supply port. After commissioning, record the air pressure used and the observed actuation levels on the instrument file, because these numbers make later troubleshooting much faster. Label the three ports at the switch so that a maintenance technician can see which one is the inlet, which is the exhaust and which is the outlet without opening the manual.
Maintenance
Inspect the air connections for leaks, since the allowed leakage is only 0.5 SCFH at 100 psig. Drain the air filter, check that the float moves freely, and test the alarm function at each shutdown. Replace parts only with those listed by the manufacturer.
Related items you may also need: Magnetrol 089-7827-011 LVDT Kit, Low Temperature, for E4 Modulevel | Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay | Magnetrol 089-7905-001 TG1 DIN Rail Housing and Electronics | All Magnetrol products.
Checklist before ordering the Magnetrol Tuffy Pneumatic
- Before ordering the Magnetrol Tuffy Pneumatic, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
- Our team confirms the Magnetrol Tuffy Pneumatic code, condition and lead time in writing before any order is placed.
- The datasheet attached to this page is the reference for the Magnetrol Tuffy Pneumatic dimensions, ratings and wiring.
- The Magnetrol Tuffy Pneumatic is listed in our level switches range and ships to sites across Oman and the GCC.
- Spare quantities of the Magnetrol Tuffy Pneumatic are worth planning for critical duty so that a failure does not stop production.
Documents and quotation
The Magnetrol catalogue 44-109 is provided as the datasheet for the Magnetrol Tuffy Pneumatic. Send your RFQ with the part number Magnetrol Tuffy Pneumatic, the specific gravity code, the connection type and the quantity, and we will respond with availability for Oman and the GCC.
Other Models in the Tuffy Range
Seven Star LLC supplies models from the Tuffy range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Tuffy II Side-Mounted Float Level Switch | Level Switches | View details |
| Magnetrol Tuffy Pneumatic Side-Mounted Float Switch | Level Switches | You are viewing this model |
Datasheets & Documents
- Datasheet Magnetrol Tuffy Pneumatic Side-Mounted Float Switch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Tuffy Pneumatic Side-Mounted Float Switch
Answers from our engineering team on installation, compatibility and integration.
01What does the Magnetrol Tuffy Pneumatic switch do?
It operates a single pneumatic switch mechanism for high or low level alarm or control, using a float and magnet to change the state of a three-port air valve.
02What pressure rating does the Tuffy Pneumatic have?
The standard rating is 1500 psig at 300 degrees Fahrenheit for a minimum specific gravity of 0.60 and 500 psig for a minimum of 0.40, with an optional cage rated up to 2200 psig.
03What air supply does the Tuffy Pneumatic need?
The pneumatic switch accepts vacuum to 200 psig supply pressure, with leakage of 0.5 SCFH and a minimum air flow of 2.0 SCFM at 100 psig.
04What process temperature can the Tuffy Pneumatic handle?
It is rated from minus 40 to plus 300 degrees Fahrenheit (minus 40 to plus 149 degrees Celsius), with a maximum ambient temperature of 100 degrees Fahrenheit at maximum process temperature.
05Is the Tuffy Pneumatic available for sour service?
Yes. It has 316 stainless steel wetted parts and NACE and ASME B31.3 construction options, with some cage types to be confirmed with the factory.