Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon Steel Flange
Description
Magnetrol 004-5867-029: 4 Inch Class 300 Carbon Steel Flange
Every plant has older lines where the nozzle is a 4 inch Class 300 raised face flange and the pipe itself is carbon steel. For those places the Magnetrol 004-5867-029 gives a Thermatel TG1 sensor a flange of the same metal, which avoids the dissimilar-metal joint that a stainless flange on a carbon steel stub would create.
The manufacturer lists this flange in the TG1 manual as part of a table with fifteen carbon steel, fifteen stainless and fifteen Hastelloy cells, although not all sizes appear in every class. The 4 inch 300 lbs carbon steel cell is 004-5867-029; its stainless counterpart is 004-5867-009 and its Hastelloy counterpart is 004-5867-039.
As the manual points out, thread-on flanges can only be combined with a sensor that has the 3/4 inch NPT-M process connection. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of 004-5867-029
- Magnetrol 004-5867-029 is the 4 inch, 300 lbs raised face thread-on flange in carbon steel for the Thermatel TG1.
- Carbon steel is the first of the three material columns in the manual, next to 316/316L and Hastelloy C.
- It screws onto a 3/4 inch NPT-M sensor, so no sensor welding or special machining is needed.
- In the 300 lbs group it follows 004-5867-028 (3 inch) and precedes 004-5867-030 (6 inch) in carbon steel.
- The row is printed once in the manual, which makes the number easy to verify from the PDF supplied with this page.
Technical data for 004-5867-029
| Parameter | Value |
|---|---|
| Part number | 004-5867-029 |
| Part type | Thread-on mounting flange for Thermatel TG1 sensor |
| Flange size | 4 inch |
| Pressure class | Class 300 (300 lbs), raised face, ASME B16.5 |
| Flange material | carbon steel |
| Sensor thread it fits | 3/4 inch NPT male process connection only |
| Sensor families (3/4 NPT code 110) | TMA, TMB, TMC, TMD, TMH and TMM |
| Source document | Bulletin BE 54-605 Thermatel TG1 installation and operating manual, model identification section 4 |
The sensors that receive this flange have their own limits, and those limits do not change because a flange is added. The table below lists the sensor data that the manual publishes for the 3/4 inch NPT versions.
| Sensor type | Maximum process pressure |
|---|---|
| TMA/TMB spherical tip, material A | 41.4 bar (600 psi) at +40 C, 33.8 bar (490 psi) at +120 C |
| TMC/TMD twin tip, minimum insertion length | 207 bar (3000 psi) at +40 C, 170 bar (2460 psi) at +120 C |
| TMC/TMD twin tip, longer than minimum | 128 bar (1850 psi) at +40 C, 105 bar (1517 psi) at +120 C |
| TMH high temperature sensor | 414 bar (6000 psi) at +40 C, 233 bar (3380 psi) at +450 C |
| Sensor diameter | 22.9 mm (0.90 inch), TMH 21.9 mm (0.86 inch) |
| Sensor length range | 5 to 330 cm (2 to 130 inch); TMH 5.5 to 91 cm |
Where 004-5867-029 is used in oil and gas, utilities, water and manufacturing
Class 300 and carbon steel is a typical combination on hydrocarbon gas lines, fuel gas headers and flare knock-out pipework in oil and gas plants. A TG1 on such a line is normally used as a low-flow alarm that proves purge, seal or cooling gas is moving. The 4 inch size is common where the sensor is placed in a spool piece off a main run.
Power stations in the GCC use Class 300 carbon steel on auxiliary steam and condensate services as well, and the same flange can be ordered when a thermal dispersion switch is added to prove drain or vent flow. Stay within the temperature limits of the chosen sensor: +120 C for standard sensors and +200 C with the heat extension.
How 004-5867-029 differs from other Thermatel TG1 flange variants
| Flange 004-5867-029 | Comparison |
|---|---|
| Class | 300 lbs RF; the 150 lbs twin is 004-5867-024 |
| Material | Carbon steel; 316/316L twin is 004-5867-009 |
| Size | 4 inch; 3 inch is 004-5867-028 and 6 inch is 004-5867-030 |
| Sensor families | TMA to TMD, TMH, TMM with 3/4 inch NPT |
| Heat extension | Sensors with heat extension reach +200 C (TMB, TMD) and TMH reaches +450 C |
Where 004-5867-029 differs from 004-5867-024 is the class: the 150 lbs 4 inch carbon steel flange has a different face thickness and bolt pattern from the 300 lbs flange, so the wrong choice means the nozzle will not match. Between 004-5867-029 and 004-5867-009 the class and size agree while the metal changes.
Selection and compatibility for 004-5867-029
- Material: carbon steel. Use the stainless (004-5867-009) or Hastelloy C (004-5867-039) twin where the process or the environment attacks carbon steel.
- Size and class: 4 inch, 300 lbs RF; the mating flange must match.
- Sensor: only 3/4 inch NPT-M sensors accept thread-on flanges.
- Check that the weakest element of the assembly, flange, sensor or gasket, still suits the design pressure.
Fitting 004-5867-029 to the sensor
Fit the flange to the sensor thread before the sensor is inserted in the line, because the combination is easier to align on a bench. Use a gasket of a material that suits the fluid, torque the stud bolts in a cross pattern, and keep the sensor housing orientation so the cable entry (M20 x 1.5 or 3/4 inch NPT, depending on the housing code) faces down to avoid water ingress.
Run the 2-wire shielded cable of 0.50 mm2 to the DIN rail amplifier, which is rated IP 20 and belongs in a panel.
Maintenance and inspection of 004-5867-029
Carbon steel needs a paint or coating plan in a coastal Oman atmosphere. Look at the flange and bolting at each inspection round for corrosion scale, particularly under the insulation if it is lagged, and replace the part before the face is attacked enough to affect the gasket seat. Keep 004-5867-029 on the spare list for any sensor that is removed regularly for calibration.
Documents and quotation
The manufacturer manual BE 54-605 that lists 004-5867-029 is supplied with this page as a datasheet download; it contains the flange table, the sensor ordering code and the pressure and temperature ratings quoted above. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request pricing and lead time, send an RFQ that gives the part number 004-5867-029, the quantity, the sensor model code and the delivery location in Oman or the GCC, and we will reply with availability.
Other Models in the Magnetrol Tg1 Flange Range
Seven Star LLC supplies models from the Magnetrol Tg1 Flange range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 004-5867-056 TG1 2 Inch Class 600 Hastelloy C Flange | Thermal Mass Flow Meters & Controllers | View details |
| Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon Steel Flange | Thermal Mass Flow Meters & Controllers | You are viewing this model |
| Magnetrol 004-5867-043 TG1 1 Inch Class 150 316 SS Flange | Thermal Mass Flow Meters & Controllers | View details |
| Magnetrol 004-5867-003 TG1 3 Inch Class 150 316 SS Flange | Thermal Mass Flow Meters & Controllers | View details |
Datasheets & Documents
- Datasheet Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon Steel Flange Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon
Answers from our engineering team on installation, compatibility and integration.
01What does 004-5867-029 describe?
It is the thread-on mounting flange for the Magnetrol Thermatel TG1 in 4 inch, 300 lbs raised face, carbon steel, according to manual BE 54-605.
02Is carbon steel the only option in this size and class?
No. The same 4 inch 300 lbs RF size is also listed in 316/316L as 004-5867-009 and in Hastelloy C as 004-5867-039.
03Can I use this flange on a 1 inch NPT sensor?
No. The manual says thread-on flanges can only be used with sensors that have the 3/4 inch NPT male process connection.
04What maximum temperature do the TG1 standard sensors handle?
The manual lists up to +120 C for standard TMA and TMC sensors and up to +200 C for the TMB and TMD sensors with heat extension; the TMH sensor reaches +450 C.
05How do I order 004-5867-029 from Seven Star LLC?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.


















Reviews