Leuze MLC520R20-1950 Safety Light Curtain Receiver
Description
Overview
Leuze MLC520R20-1950 is the receiver half of a safety light curtain pair from the MLC 500 range of Leuze electronic, part number 68002219. It guards a 1,950 mm tall opening with a resolution of 20 mm, which is the classification the datasheet gives for hand protection. When a hand or an object interrupts any beam between the transmitter and the receiver, the two safety outputs drop within 34 ms and the machine can be stopped. The curtain is a Type 4 device to IEC/EN 61496 and reaches SIL 3, SILCL 3 and Performance Level e with category 4, so it suits the highest safety functions normally asked of an electro-sensitive protective device.
Safety figures of Leuze MLC520R20-1950 at a glance
- Type 4 per IEC/EN 61496; SIL 3 per IEC 61508; SILCL 3 per IEC/EN 62061.
- Performance Level e and category 4 per EN ISO 13849-1, with a mission time of 20 years.
- PFHD of 7.73E-09 per hour, a number the machine builder needs for the safety calculation.
- Two OSSD outputs, PNP transistor type, 380 mA each, short-circuit and overvoltage protected.
- Response time of 34 ms and a restart delay of 100 ms.
Leuze MLC520R20-1950 specification table
| Parameter | Value |
|---|---|
| Part number | 68002219 |
| Series | MLC 500 |
| Device type | Safety light curtain receiver (transmitter ordered separately) |
| Application | Hand protection |
| Function package | Standard: transmission channel changeover, start/restart interlock (RES), contactor monitoring (EDM) |
| Type | Type 4, IEC/EN 61496 |
| SIL / SILCL | SIL 3 (IEC 61508), SILCL 3 (IEC/EN 62061) |
| Performance Level | PL e, EN ISO 13849-1, category 4 |
| PFHD | 7.73E-09 per hour |
| Mission time | 20 years |
| Resolution | 20 mm |
| Nominal protective field height | 1,950 mm |
| Effective protective field height | 1,967 mm |
| Supply voltage | 24 V DC, minus 20 to plus 20 percent |
| Current consumption | 150 mA maximum, 2 A semi time-lag fuse |
| Safety outputs | 2 OSSD, PNP transistor, 380 mA maximum each |
| Response time | 34 ms |
| Restart delay time | 100 ms |
| Connection | M12 metal male connector, 8-pin, A-coded |
| Cable length | Up to 100 m, 0.25 mm2 conductor |
| Housing | Aluminium profile, yellow RAL 1021, PMMA lens cover |
| Dimensions (W x H x L) | 29 x 2,016 x 35.4 mm |
| Weight | 2,100 g net |
| Display | 7-segment display and 2 LEDs |
| Ambient temperature | Minus 30 to 55 degrees C operation, minus 30 to 70 degrees C storage |
| Protection | IP 65, protection class III |
| Vibration / shock | 50 m/s2 / 100 m/s2 |
| Approvals | TUEV Sued, c CSA US, c TUEV NRTL US, S Mark |
Transmitter pairing for MLC520R20-1950
MLC520R20-1950 is a receiver only. The datasheet names the matching transmitter as MLC500T20-1950, part number 68000219, with 20 mm resolution, 1,950 mm protective field height, an operating range of 0 to 15 m and a 5-pin metal M12 connector. A transmitter and a receiver must have the same resolution and height, so both sides need to be ordered when you build a new guard. For a replacement, check which half has failed and confirm the code on the nameplate.
How MLC520R20-1950 differs from other MLC 500 variants
The code MLCxyy-za-hhhhei-ooo is explained in the datasheet. Here the 5 is the MLC 500 series, 20 is the standard receiver with EDM and RES selectable, R marks the receiver and 20 the resolution of 20 mm, followed by the 1950 mm field height. Other positions give very different behaviour: function class 10 is a basic receiver with automatic restart, class 30 is the extended receiver with blanking and muting, and resolutions of 14, 30, 40 and 90 mm exist. Heights range from 150 to 3000 mm. Options include /A for an AS-i interface, /V for high vibration, EX2 for explosion protection zones 2 and 22, and SPG for Smart Process Gating. MLC520R20-1950 has none of these options.
Protective field geometry of MLC520R20-1950
For MLC520R20-1950 the effective protective field height is longer than the nominal one: HPFE equals the nominal 1,950 mm plus 7 mm plus 10 mm, which gives 1,967 mm. The total profile height is 2,016 mm. When working out safety distances to the hazard, use the effective value and the response time, together with the stopping time of the machine, as required by the applicable safety-distance standard.
Applications in Oman and the GCC
MLC520R20-1950 typically guards the access opening of robotic cells, palletisers, packaging lines, press brakes and automated warehouses in Omani manufacturing and logistics plants. With an upper temperature of 55 degrees C and IP 65, it can sit in hot industrial halls, but not outdoors without a cover. For hazardous areas the EX2 variants are separate products and not covered here.
Wiring and mounting of MLC520R20-1950
Wiring uses an 8-pin M12 connector: pin 1 is IO1, pin 2 VIN1, pin 3 IN3, pin 4 IN4, pin 5 OSSD1, pin 6 OSSD2, pin 7 VIN2 and pin 8 IN8. Connecting VIN1 to 24 V and VIN2 to 0 V selects transmission channel C1, and the reverse selects C2, which is the changeover between the two transmission channels. Cable length may be up to 100 m with a loop resistance of at most 200 ohms. Mounting is on a Device Column, in the groove, with brackets or on a swivel mount. Two BT-NC sliding blocks are included.
Commissioning and checks
After installing MLC520R20-1950, align the receiver to the transmitter until the LED shows steady green, then carry out the verification tests required by the machine builder. The LEDs show red when the OSSDs are off, flashing red at 1 Hz for an external error and at 10 Hz for an internal one, and flashing green at 1 Hz when the signal is weak. Select RES and EDM as required by the risk assessment. Repeat the tests at the intervals defined by the machine documentation.
Ordering MLC520R20-1950
Provide the designation, part number 68002219, quantity, and whether the matching transmitter and cables are needed. Confirm the full order code on the nameplate for replacement jobs.
For delivery planning in Oman, confirm the full Leuze MLC520R20-1950 article number against the nameplate or your existing installation before ordering.
Buyers searching for Leuze MLC520R20-1950 can send the application details with the request so the quotation matches the installation.
Related items you may also need: EUCHNER CTA-L1-BP-U-HA-AP-SA Guard Locking Safety Switch | Banner RP-QM90F-100L Rope Pull Emergency Stop Switch | Schmersal SRB301MC-24V Safety Relay Module 3 Contacts | All Leuze products.
Documents and quotation
The manufacturer datasheet for MLC520R20-1950 holds the safety data, wiring, LED table, part number code and accessories. Seven Star LLC is an independent supplier serving Oman and the GCC. Send your RFQ with part number, quantity and delivery location.
Datasheets & Documents
- Datasheet Leuze MLC520R20-1950 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Leuze, trading as Leuze electronic, is a German maker of optical sensors, bar code readers, safety light curtains, distance and positioning systems and optical data transmission. The company was founded in 1963 in Owen/Teck at the foot of the Swabian Alb by Helmut, Christof and Adolf Leuze, in part of a former family textile mill, with four employees. Its business idea from the start was electronic optical sensing for industry, and it is still a family-owned company led today by the fifth generation of the founding family.
Leuze company profile
| Founded | 1963, Owen/Teck, Germany, by Helmut, Christof and Adolf Leuze |
|---|---|
| Headquarters | Owen/Teck, Baden-Wuerttemberg, Germany |
| Ownership | Family-owned; the family's textile roots go back to the 17th century and a cotton mill founded in 1861 |
| Core technology | Photoelectric sensing with LED and laser light: switching sensors, bar code readers, light curtains, laser distance measurement and optical data links |
| Typical applications | Conveyors and logistics, packaging, storage and retrieval systems, cranes and gantries, machine guarding |
| Standards | Safety light curtains to IEC/EN 61496 Type 4, SIL 3 and Performance Level e; sensors to IEC 60947-5-2; bar code readers with UL approval |
Milestones
- 1861: The Leuze family sets up a mechanical cotton weaving and spinning mill in the Lenningen valley.
- 1963: Leuze electronic is founded in Owen/Teck.
- Mid-1970s: LEDs are built into sensors, and the DDLS 78 optical data light barrier is introduced as the first of its kind for industry.
- 1980s: The first retro-reflective photoelectric sensor opens the packaging industry as a market.
- 2023: The company marks its 60th anniversary.
How Leuze optical sensing and bar code reading work
Most of these products work by sending out light and judging what comes back. In a safety light curtain such as the MLC 500 series, a transmitter and a receiver face each other, and an interrupted beam makes the safety outputs switch off within milliseconds. In a BCL bar code reader a rotating polygon mirror wheel sweeps a red laser line across the label up to 1,000 times a second, and the reader decodes the bars it sees. A BPS positioning system reads a bar code tape along a track, while an AMS system measures the travel time of a laser to a reflector up to 120 m away. Short-range ODS sensors use an infrared LED and give a distance value. When selecting, match the reading distance, module size or protective resolution to the real task first, and only then the bus interface of your controller.
Where Leuze products are used in Oman and the GCC
These devices are found wherever material moves automatically: port and distribution-centre conveyors in Sohar, Duqm and Salalah, packaging and bottling lines, automated stores and overhead cranes in workshops. Guarding of robot cells and presses also relies on light curtains. Most devices are fitted indoors or in sheltered enclosures because their rated ambient temperatures are typically up to 40 to 55 degrees C.
Leuze models we list
| Family | Examples |
|---|---|
| Stationary bar code readers (BCL 300i) | BCL 348i SN 100 D, BCL 358i OF 100 |
| Bar code positioning (BPS 300i) | BPS 348i SM 100 D |
| Laser distance measuring systems (AMS 300i) | AMS 348i 120 |
| Safety light curtains (MLC 500) | MLC520R20-1950 |
| Optical distance sensors (ODS 96B) | ODS 96B M/C6-600-S12, ODS 96B M/V6-1400-S12 |
Ordering Leuze products: what we need
For a quotation, send the full type designation and the numeric part number from the nameplate, such as 50116458, together with the quantity and the fieldbus used. For spares and replacements, add a photo of the nameplate, because small letters in the type code change interface, optics or beam exit. Seven Star LLC is an independent supplier serving Oman and the GCC.
Facts checked against the Leuze company history and published product datasheets, November 2026.
Browse Leuze products by category: Laser Distance, LiDAR & Radar Sensors, Safety Switches & Guard Locking, Machine Vision.
FAQ
Questions about the Leuze MLC520R20-1950 Safety Light Curtain Receiver
Answers from our engineering team on installation, compatibility and integration.
01What protection does Leuze MLC520R20-1950 give?
It is a Type 4 safety light curtain receiver with 20 mm resolution for hand protection and a 1,950 mm nominal protective field height, reaching SIL 3 and PL e.
02Which transmitter goes with Leuze MLC520R20-1950?
The datasheet names the MLC500T20-1950 with part number 68000219, 20 mm resolution, 1,950 mm height and an operating range of 0 to 15 m.
03What is the response time of Leuze MLC520R20-1950?
The response time is 34 ms and the restart delay time is 100 ms; the two OSSD outputs are PNP transistors with up to 380 mA each.
04Which functions does Leuze MLC520R20-1950 offer?
The standard function package gives transmission channel changeover, start/restart interlock (RES) and contactor monitoring (EDM).
05What is the effective protective field height of Leuze MLC520R20-1950?
The nominal height of 1,950 mm plus 7 mm and 10 mm gives an effective protective field height of 1,967 mm, with a total height of 2,016 mm.


















Reviews