- Automation & ControlView all 3,183 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Autonics
Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm 2-Stage
Description
Overview
Think of a filling station that must slow its conveyor at 90 percent of a batch and stop it at 100 percent. One preset is not enough for that; two are. The Autonics CT6S-2P4 is a 48 by 48 mm programmable counter and timer with six digits and two independent preset stages, OUT1 and OUT2, which can be switched at different count values or elapsed times. It takes 100 to 240 VAC, offers relay and NPN transistor outputs and counts at up to 10 kcps from electronic sensors.
Seven Star LLC is an independent supplier serving Oman and the GCC. The 48 mm square size is the most common panel cut-out of all, so this code is a frequent request for like-for-like replacement of counters in older machines.
Autonics CT6S-2P4 key specifications
| Parameter | Value |
|---|---|
| Display | 6-digit LED, count value red, setting value green |
| Character size | Count value 4.5 x 10 mm, setting value 3.5 x 7 mm |
| Case size | DIN 48 x 48 mm, depth about 90 mm |
| Panel cut-out | 45 mm square, plus 0.6 mm |
| Presets | 2-stage (OUT1 and OUT2) |
| Counting range | -99999 to 999999 |
| Max. counting speed | 1 cps, 30 cps, 1 kcps, 5 kcps or 10 kcps |
| Relay outputs | 250 VAC 5 A or 30 VDC 5 A resistive |
| Transistor output | NPN open collector, 30 VDC, 100 mA |
| Supply | 100 to 240 VAC, 50 and 60 Hz, 90 to 110 percent tolerance, up to 12 VA |
| Sensor supply | 12 VDC, 100 mA |
| Prescale | 0.00001 to 99999.9 |
| Time range | 0.001 s to 99999.9 hours |
| Memory | Non-volatile, about 10 years |
| Temperature | -10 to 55 C |
| Front protection | IP65 |
Using the two stages of the Autonics CT6S-2P4
In counter mode the first preset can warn and the second can act. A packaging line might use OUT1 to start a slow-down valve at 950 cartons and OUT2 to stop the feeder at 1,000. In timer mode the two stages create staged delays, such as a pre-alarm followed by a shutdown. A one-shot output time between 0.01 and 99.99 seconds can turn a stage into a pulse for a kicker or a marker.
The green display shows the setting value during run, and the [PS1] and [PS2] indicators light when the preset values are being checked or edited. Key lock prevents tampering after the setting has been proven.
How CT6S-2P4 differs from other CT variants
Compared with the CT6S-1P4, which has one preset stage, this model adds a second output. Compared with the CT4S-2P4, which has four digits and a range of -999 to 9999, it has six digits and a much larger range. Compared with the CT6M-2P4 in the 72 mm square case, it has smaller digits but needs less panel space.
The power code 4 means 100 to 240 VAC; code 2 would give 24 VAC or 24 to 48 VDC. A T would add RS485 Modbus RTU. In short, every character of CT6S-2P4 can be traced: six digits, 48 mm size, two presets, mains supply, no communication.
Input wiring
INA is the pulse input, INB or INHIBIT the second input, and RESET clears the display. Both PNP-type voltage inputs (5 to 30 VDC high) and NPN-type no-voltage inputs are supported through the input logic setting. Use the 12 VDC output to power a sensor. Contact inputs such as limit switches should be limited to 1 cps or 30 cps to avoid chatter errors; electronic sensors can use the faster settings.
Counting modes and prescale
Nine input modes cover up, down, up and down, phase difference and command input patterns. Prescale converts pulse counts into engineering values: for example 0.5 can display metres from encoder pulses on a roll. Counting can start from any set start point, which helps when material is already loaded. Eleven output modes decide how and when the outputs turn on, hold or reset.
Installation notes
Cut a 45 mm square opening and fit the unit with the supplied bracket. Allow about 65 mm of free space around for neighbouring units as in the panel cut-out table. Terminal protection covers are available as an accessory. Isolate the supply with a switch or breaker, and route signal wires away from power conductors. In Gulf switchrooms with high temperature, check that the panel stays below 55 C.
Where it is used
Typical roles are batch counting on bottling lines, sheet counting on cutters, cycle counting on presses, and run-hour or delay timing on pumps and conveyors. The two outputs make it a simple alternative to a PLC when a stand-alone batch controller is needed. A water bottling plant, for example, can wire a proximity sensor from the filler star-wheel to INA, use OUT1 to reduce the filling speed near the end of the batch and OUT2 to close the final valve, then use the RESET input from the pallet sensor to start the next batch. Textile and cable lines use the same pattern with length pulses from an encoder, scaled by the prescale so that the display shows metres directly. In utilities, the timer function runs standby pumps for a set period or delays the start of a second pump after the first, with the two stages giving a start delay and a run limit. Because all settings stay in non-volatile memory, a power cut in the middle of a shift does not lose the count of the batch in progress, which matters on sites with unstable supply.
Ordering
Send Autonics CT6S-2P4 on your RFQ with the quantity. The RS485 version of this code ends in T, and terminal covers are separate items.
Related items you may also need: Autonics BEN5M-MFR Retroreflective Photoelectric Sensor 5 m | Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | Autonics PR18-8DN M18 Inductive Proximity Sensor 8 mm | All Autonics products.
Documents and quotation
The manufacturer publishes a product manual that covers Autonics CT6S-2P4, and the PDF is attached to this page for download so your engineers can check wiring, ratings and dimensions before ordering. Please send your RFQ with the part number and the quantity you need, plus the delivery site, and our team will reply with availability and lead time.
Other Models in the CT Range
Seven Star LLC supplies models from the CT range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Autonics CT6S-1P4 6-Digit Counter Timer 48×48 mm | Controllers & Data Acquisition | View details |
| Autonics CT6M-2P4 72×72 Six-Digit Counter/Timer 2-Stage | Photoelectric Sensors | View details |
| Autonics CT4S-1P4 48×48 4-Digit Counter/Timer 1-Stage | Photoelectric Sensors | View details |
| Autonics CT6S-2P2 48×48 6-Digit Counter/Timer 24 V | Photoelectric Sensors | View details |
| Autonics CT6Y-1P4 Programmable 6-Digit Counter Timer 72 x 36 | Controllers & Data Acquisition | View details |
| Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm 2-Stage | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm 2-Stage Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.
Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.
Autonics company profile
| Founded | 1977, South Korea |
|---|---|
| Current name | Autonics, since 1988 |
| Headquarters | Busan, South Korea |
| Factories | Busan and Yangsan |
| Product families | E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers |
Milestones
- 1977: The company is founded.
- 1988: Renamed Autonics Corporation.
- 2014: Opens its Busan headquarters.
Reading the Autonics E40S encoder code
E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.
Where Autonics encoders are used
Servo and spindle feedback, conveyor length measurement, packaging and printing machines.
Ordering Autonics encoders: what we need
Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.
Facts checked against Autonics corporate profiles, October 2026.
Browse Autonics products by category: Encoders.
FAQ
Questions about the Autonics CT6S-2P4 6-Digit Counter Timer 48 x 48 mm
Answers from our engineering team on installation, compatibility and integration.
01What is special about the Autonics CT6S-2P4?
It has six digits in a 48 x 48 mm case and two preset stages, so one counter can give a warning output and a stop output.
02What supply does CT6S-2P4 use?
The 4 in the code means 100 to 240 VAC at 50 or 60 Hz; the 2 version is for 24 VAC or 24 to 48 VDC.
03What panel cut-out is required?
A 45 mm square cut-out with a tolerance of plus 0.6 mm, with the unit about 90 mm deep.
04How fast can it count?
The counting speed can be set to 1 cps, 30 cps, 1 kcps, 5 kcps or 10 kcps; contact inputs should use 1 or 30 cps.
05Can the display show engineering units?
Yes. A prescale value from 0.00001 to 99999.9 converts pulses into a scaled display value.


















Reviews