EUCHNER LCA-4TR-40-1060-AP-156554 Safety Light Curtain
Description
Overview
Tall openings need a tall curtain, and the EUCHNER LCA-4TR-40-1060-AP-156554 covers a protective field of 1060 mm with a sensor length of 1113 mm. It belongs to the LCA 4 line of EUCHNER safety light curtains and is a Type 4 device under EN 61496-1. The resolution is 40 mm, and the product page lists an extended range of 20 m together with an LED indicator for weak signal. The order number is 156554.
The extended range is the feature that most often decides the selection. Wide conveyor entries, large press apertures and machine cells with long approach distances call for beams that reach across several metres without losing margin, and the weak signal LED gives the installer a visual warning before the margin disappears. Installation material comes with the product, and the connection uses M12 plugs, five pins on the transmitter and eight pins on the receiver.
Seven Star LLC is an independent supplier serving Oman and the GCC. Ask us about complete sets for your site, including cables and a safety relay.
Data table for EUCHNER LCA-4TR-40-1060-AP-156554
| Parameter | Value |
|---|---|
| Order number | 156554 |
| ESPE type | Type 4 (EN 61496-1) |
| Resolution | 40 mm |
| Protective field height | 1060 mm |
| Sensor height | 1113 mm |
| Range of the protective field | 20000 mm, extended range |
| Signal indication | LED SIGNAL LOW for weak signal |
| Response time | 6.5 ms |
| Safety outputs | 2 static, self-monitoring PNP, short-circuit and overload protected |
| Current per output | Max 400 mA |
| Supply | 24 V DC, minus 20 % to plus 20 % |
| Power consumption | Receiver 2 W, transmitter 1 W |
| Category / PL / SIL | 4 / e / 3 |
| PFH | 1.35 x 10 to the power of minus 8 per hour |
| Mission time | 20 years |
| Cross-section | 28 x 30 mm |
| Connection | M12, transmitter 5-pin, receiver 8-pin |
| Cable length, maximum | 100 m |
| Protection | IP65 / IP67 |
| Ambient / storage temperature | minus 30 to plus 55 / minus 30 to plus 70 degrees C |
| Cascading | Not possible |
How EUCHNER LCA-4TR-40-1060-AP-156554 differs from other LCA 4 variants
Compared with the 30 mm unit 156514, whose field is 460 mm and whose range is 12 m, the EUCHNER LCA-4TR-40-1060-AP-156554 has a coarser resolution of 40 mm, a field more than twice as tall at 1060 mm, and a range of 20 m. The response time improves from 7.5 ms to 6.5 ms, the PFH value changes from 1.08 x 10 to the power of minus 8 per hour to 1.35 x 10 to the power of minus 8 per hour, and an additional SIGNAL LOW LED is present.
The difference in resolution has a direct effect on where the curtain may be placed. A 40 mm resolution detects a smaller object than a body but not as small as a finger, so the installer treats it as hand and arm detection in a larger opening and calculates the safety distance using the applicable standard for that resolution. Where fingers could reach the hazard, the 30 mm class of curtain is the more suitable choice.
Indicators and connector assignments
The LEDs OK, ERROR, STOP, TEST and START show normal operation, a fault state, the stop state, the test function and start or restart, and the SIGNAL LOW LED indicates a weak signal. On the transmitter connector, pin 1 carries 24 V DC, pin 3 carries 0 V, pins 2 and 4 are RANGE 0 and RANGE 1 for configuration according to EN 61131-2, and pin 5 is functional earth.
The receiver carries FO1A on pin 1, 24 V on pin 2, FO1B on pin 3, the contactor feedback and restart input on pin 4, configuration inputs SEL A and SEL B on pins 5 and 6, 0 V on pin 7 and functional earth on pin 8. EUCHNER notes that functional earth must be connected to meet the EMC requirements.
Site scenarios in Oman and the GCC
- A wide infeed on a corrugated board or plastics sheet line where operators load by hand and a long reach is needed.
- A pallet exit at the end of a bottling line in a food and beverage plant.
- A robotic welding or assembly cell opening in a fabrication yard.
- A service entrance to a pump or valve test bench in an industrial workshop.
- A large packaging machine where the carton enters across more than a metre of width.
Mounting and alignment practice
Mount both sensors on rigid surfaces that do not flex, since vibration can cause nuisance stops on a field more than a metre tall. The mounting bracket, plate and hardware are supplied, and the sensors can be installed in any orientation. Align the transmitter and receiver so that they face each other squarely, use the SIGNAL LOW indicator as an alignment aid, and clean the front screens before final checks.
The curtain cannot be cascaded. Muting is possible only with external sensors and an evaluation unit, so any pallet passage needs a properly designed muting arrangement. Keep reflective surfaces out of the field edges, because reflections can bridge the beams.
Testing and upkeep
After installation and after any change to the machine, test the curtain with the test object recommended in the operating instructions, walking the object along the whole protective field and confirming the machine stops. Repeat at the intervals required by your safety procedure. Clean front screens with a soft damp cloth, never with solvents, and replace any sensor with a cracked housing or damaged cable.
Record each test in the machine logbook together with the date, the name of the person who carried it out and the result, so that auditors and insurers can follow the history of the safety device without searching for loose paperwork. If the SIGNAL LOW indicator lights during normal operation, treat it as a warning of dirt or drifting alignment and fix it before it leads to stops.
Related items you may also need: EUCHNER ESM-BA301 Safety Relay | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | EUCHNER CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety Switch | All EUCHNER products.
Documents and quotation
The EUCHNER operating instructions for light grids and light curtains accompany this page. For a quotation on the EUCHNER LCA-4TR-40-1060-AP-156554, send an RFQ to Seven Star LLC with the part number LCA-4TR-40-1060-AP-156554, the quantity of pairs and the delivery destination, and tell us whether you need connecting cables or a safety relay.
Datasheets & Documents
- Datasheet EUCHNER LCA-4TR-40-1060-AP-156554 Safety Light Curtain Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER LCA-4TR-40-1060-AP-156554 Safety Light
Answers from our engineering team on installation, compatibility and integration.
01What is the range of this light curtain?
The product page lists an extended range of 20 m, which is 20000 mm, along with a LED indicator for weak signal.
02What is the protective field height?
The protective field height is 1060 mm and the sensor height is 1113 mm, with a cross-section of 28 x 30 mm.
03Which safety figures apply?
Type 4 under EN 61496-1, Category 4, PL e and SIL 3, with a PFH value of 1.35 x 10 to the power of minus 8 per hour and a mission time of 20 years.
04How fast does it respond?
The response time is listed as 6.5 ms. Use this value together with the machine stopping time when calculating the safety distance.
05Is installation material supplied?
Yes. The product page states that installation material is included with the product, so a bracket and mounting plate set arrives with each sensor.


















Reviews