Brand:

ebm-papst 8500 N AC Axial Panel Compact Fan 80 mm 115 V 60 Hz

Description

Overview

Eighty millimetres is the size of fan found in a huge share of small enclosures, and the ebm-papst 8500 N is the ebm-papst AC axial panel compact fan made for that cut-out. It runs on 115 V at 60 Hz, turns at 3200 rpm, consumes 11 W and delivers 61 cubic metres per hour in free air at a sound pressure level of 34 dB(A). The ambient range is minus 10 to plus 75 degrees C and the weight is only 0.490 kg. It is intended for compact electronic and electrical equipment where space is tight but heat must still go. Seven Star LLC is an independent supplier serving Oman and the GCC.

Key data for ebm-papst 8500 N

Item ebm-papst value
Item ebm-papst 8500 N, motor -0
Phase and voltage 1 phase, 115 VAC, 60 Hz
Speed 3200 rpm
Power consumption 11.0 W
Air flow 61 m3/h
Sound power level 4.8 B
Sound pressure level 34 dB(A)
Ambient temperature minus 10 to plus 75 degrees C
Weight 0.490 kg
Dimensions 80 x 80 x 38 mm
Impeller and housing Painted sheet steel; die-cast aluminium
Airflow direction Exhaust over struts
L10 life at 40 degrees C / maximum temperature 55000 h / 25000 h

Reading the construction

The panel compact family has a stiff die-cast aluminium frame of 38 mm depth, and the sheet steel impeller is painted black. Exhaust over struts means that the air leaves on the strut side of the frame, which determines how the cooling air is guided. The datasheet gives life values of 55000 hours at 40 degrees C and 25000 hours at the upper temperature limit, which makes the fan a long-life part when it runs in a cooler enclosure. Installation hardware is simple, and the four corner holes match the standard 80 mm pattern of panel fans.

How the ebm-papst 8500 N differs from the 3606

The 3606 is a 92 mm fan with the same supply, speed and power draw. Its airflow is 89 m3/h, noise 42 dB(A), weight 0.420 kg and ambient range minus 40 to plus 75 degrees C. The ebm-papst 8500 N gives up 28 m3/h of airflow in exchange for the smaller 80 mm frame, and it is quieter at 34 dB(A) and 4.8 B sound power. Its lowest permitted ambient is minus 10 degrees C, so do not choose it for freezing environments. The difference in size matters: the cut-out of the ebm-papst 8500 N is about 12 mm smaller each way, which can decide whether the fan fits a crowded panel.

Uses across Oman and the GCC

Small AC fans of this size ventilate switchmode power supplies, relays and contactor boxes, small frequency converters, signal conditioners, terminal boxes and instrumentation housings. Because the fan is rated to 75 degrees C, it can be installed in hot spots near heat-producing components. In Gulf plants a typical use is a skid-mounted junction box in direct sun, where internal temperature exceeds ambient by a large margin; a small exhaust fan with a filtered intake can keep electronics inside their limits.

Mounting and electrical connection

Use four screws in the corner holes and make sure the airflow direction is correct for your design. Supply the fan with 115 V at 60 Hz only; for a 230 V, 50 Hz network use a suitable transformer or choose a 230 V fan of the same series. Provide a finger guard at the open side and keep the intake free of obstructions. Where the fan is used in a sealed enclosure with filters, expect real airflow to be lower than the free-air figure because the curve falls as back pressure rises.

Small fans and big dust: practical enclosure design

An 80 mm fan has limited static pressure, so the way the enclosure is built decides success more than the fan itself. Arrange the intake low on one side and the exhaust high on the opposite side, so that the air passes across the warm components instead of short-circuiting from intake to exhaust. Avoid placing tall components directly in front of the fan, where they would block the flow. In dusty regions, filter mats on the intake protect the electronics but add resistance, so size the filter area generously, at least several times the fan opening, and schedule cleaning in the maintenance plan. A filter that is allowed to clog turns a fan with a margin into a fan that moves little air, and the first symptom is often a rise in the temperature alarm rather than any noise. A thermostat or temperature switch that turns the fan on only when needed reduces running hours, which extends the life figure in the datasheet proportionally, and a second thermostat with an alarm contact can warn when the enclosure overheats despite the fan.

Replacing an old 80 mm fan

When swapping fans, match the frame size, the mounting hole spacing, the supply voltage and frequency, the airflow direction and the connection type. Compare the free-air flow and the temperature rating with the old fan, and note the thickness, since a thicker fan may collide with components. If the old fan came from a different brand, the corner holes of 80 mm fans normally follow a common pattern, but the cable and the plug differ, so check how the new fan will be connected.

Maintenance

Check for noise and vibration during routine rounds and clean dust from the blades. Replace the fan before the end of its calculated life, especially in a hot enclosure, where the life figure approaches 25000 hours. Keep a spare for critical equipment, since replacement takes only a few minutes.

Estimating whether 61 m3/h is enough

A quick calculation helps. Air carries about one third of a watt-hour per cubic metre per kelvin, so 61 m3/h removes around 20 W per kelvin of temperature rise in free air. If the enclosure dissipates 40 W and may rise 10 kelvin, the flow needed is about 12 m3/h, so the fan has a large margin, even after filters take half of the airflow. For larger loads, choose a bigger fan or run two fans in cross flow.

Related items you may also need: ebm-papst R1G175-AB41-02 DC Fan | ebm-papst R1G225-AF11-52 DC Fan | ebm-papst Industrial Cooling Fan | All ebm-papst products.

Checklist before ordering the ebm-papst 8500 N

  • Before ordering the ebm-papst 8500 N, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the ebm-papst 8500 N code and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the ebm-papst 8500 N dimensions, ratings and connections.

Documents and quotation

The ebm-papst datasheet for the ebm-papst 8500 N, with nominal data, dimensions, airflow curve and drawing, is attached. Send your RFQ with ebm-papst 8500 N, the quantity and your delivery location in Oman or the GCC.

Other Models in the Ac Axial Panel Range

Seven Star LLC supplies models from the Ac Axial Panel range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ebm-papst 3606 AC Axial Panel Compact Fan 92 mm 115 V 60 HzIndustrial Fans & BlowersView details
ebm-papst 8500 N AC Axial Panel Compact Fan 80 mm 115 V 60 HzIndustrial Fans & BlowersYou are viewing this model
ebm-papst 3956 L AC Axial Panel Compact Fan 92 mm 230 V QuietIndustrial Fans & BlowersView details
Datasheets & Documents
  • PDF Datasheet ebm-papst 8500 N AC Axial Panel Compact Fan 80 mm 115 V 60 Hz Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ebm-papst is a German family-owned maker of fans and motors, headquartered in Mulfingen. It was founded in 1963 by Gerhard Sturm and Heinz Ziehl as Elektrobau Mulfingen (ebm) and took its current name after acquiring Papst in 1992. ebm-papst makes EC fans, blowers and motors for ventilation, cooling and air conditioning.

Seven Star LLC is an independent supplier in Muscat. We list ebm-papst fans for equipment cooling in Oman and the GCC.

ebm-papst company profile

Founded 1963, Mulfingen, Germany
Founders Gerhard Sturm and Heinz Ziehl
Headquarters Mulfingen, Germany
Ownership Family-owned
Product families RadiCal and R1G EC centrifugal fans, axial fans, compact DC fans, EC motors

Milestones

  • 1963: Elektrobau Mulfingen is founded.
  • 1992: ebm acquires Papst and becomes ebm-papst.

ebm-papst product series

Centrifugal fans include the R1G175-AB41-02 and R1G225-AF11-52 DC fans with backward curved impellers. Papst industrial cooling fans are used in cabinets and electronics.

Replacements should match the part number exactly, as size, voltage, airflow, speed signal and connector can differ between versions. EC fans can be speed controlled to save energy and reduce noise.

Where ebm-papst fans are used

Cooling of drives, UPS, telecom and control cabinets, HVAC units and electronic equipment.

ebm-papst products we list

Family Examples
Cooling R1G175-AB41-02 DC Fan, R1G225-AF11-52 DC Fan
Automation Accessories Papst Industrial Cooling Fan

Ordering ebm-papst fans: what we need

Send the full part number from the label, voltage and quantity.

Facts checked against ebm-papst's published company history, October 2026.

FAQ

Questions about the ebm-papst 8500 N AC Axial Panel Compact Fan 80 mm

Answers from our engineering team on installation, compatibility and integration.

01What voltage does the ebm-papst 8500 N need?
It is a single-phase 115 VAC, 60 Hz fan with 3200 rpm and 11.0 W power consumption, so a 230 V network needs a transformer or a different fan.
02How much air does the ebm-papst 8500 N move?
The datasheet lists 61 cubic metres per hour in free air with a sound pressure level of 34 dB(A) and a sound power level of 4.8 B.
03What size is the ebm-papst 8500 N?
The frame measures 80 x 80 x 38 mm, the weight is 0.490 kg, and the housing is die-cast aluminium with a painted sheet steel impeller.
04What ambient temperatures can the ebm-papst 8500 N handle?
The permitted ambient range is minus 10 to plus 75 degrees C, with calculated life of 55000 hours at 40 degrees C.
05How does the ebm-papst 8500 N differ from the 3606?
The 8500 N is a smaller 80 mm fan with 61 cubic metres per hour and 34 dB(A), while the 3606 is a 92 mm fan with 89 cubic metres per hour and a minus 40 degree limit.