Brand: EUCHNER
EUCHNER CMS-RH-AYA-03VL Magnetic Read Head, 3 m Cable
Description
Overview
Where covers are dirty, wet or vibrating, the EUCHNER CMS-RH-AYA-03VL offers a read head without moving parts. It is a cube-shaped Hall-sensor head in design A, measuring 87.5 x 25 mm, with a hard-wired PVC cable of 3 m and a green status LED. Together with a magnetic actuator, which is ordered separately, it reports the position of a guard to a CMS evaluation unit. The head itself holds no software and no settings. Seven Star LLC is an independent supplier serving Oman and the GCC.
Reading the code EUCHNER CMS-RH-AYA-03VL
CMS is the magnetically coded safety switch system, RH means read head, and AYA designates design A with a Hall-sensor principle. The digits 03 give the cable length in metres, and VL marks the version with the encapsulated cable and LED. The article number is 113207. The matching actuator CMS-MH-AA, a cube of 88 x 25 mm, carries the number 113212 and must be ordered separately.
Technical data for EUCHNER CMS-RH-AYA-03VL
| Property | Value |
|---|---|
| Design | A, cube-shaped, 87.5 x 25 mm |
| Principle | Hall sensor |
| Contacts | 1 NC plus 1 NO characteristic |
| Safe switch-off distance | 20 mm (equal to the reset distance) |
| Safe switching distance | at least 10 mm at zero centre offset |
| Switching voltage | 20 to 35 V DC |
| Switching current | up to 15 mA; current consumption up to 35 mA |
| Cable | 3 m PVC, 0.25 square mm with end sleeves |
| Housing | Glass-fibre reinforced PPS, IP67 |
| Ambient / storage | minus 5 to plus 55 / minus 25 to plus 70 degrees C |
| Tightening torque | 0.4 to 0.5 Nm |
| Mechanical life | 100 million cycles |
| Indicator | 1 green LED |
How EUCHNER CMS-RH-AYA-03VL differs from other CMS read heads
There are four read heads with Hall sensors. The CMS-RH-AYA-05VL is identical but has a 5 m cable. The CMS-RH-BYB-03VL and CMS-RH-BYB-05VL use design B, a much smaller cube of 36 x 26 mm, with 3 m and 5 m cables. So if the available space is tight, design B is the answer, while design A with its 87.5 mm length offers the larger switching distances listed above. All four work with the evaluation units CMS-E-ER and CMS-E-FR.
Why choose a magnetic read head
A magnetically coded system detects only a matching actuator, tolerates misalignment better than a mechanical switch and has no wearing parts. With 100 million mechanical cycles the EUCHNER CMS-RH-AYA-03VL outlasts almost every guard in service. It also survives conditions that eat mechanical switches: product dust, oil mist, cleaning water and vibration. It is therefore found on sorter hatches, conveyor covers, packaging lines and food processing guards.
Installation
Mount the head and the actuator with the active faces opposite each other and keep ferromagnetic material away from the pair, since the switching distances apply only when no such material is near. An optional spacer, CMS-A-SA, is sold for design A in packs of ten. Tighten fixings to 0.4 to 0.5 Nm, route the cable without tight bends and connect the sleeved conductors to the evaluation unit terminals, and check the green LED.
Commissioning and checks
Close the guard, check that the LED comes on and that the evaluation unit enables its outputs, then open the guard and confirm that they drop. Measure the real switch-off point, which should lie within 20 mm. Avoid steel plates behind the head, which can shift the switching points, and re-test after any change to the guard.
Standards and design basis
The manufacturer lists the following standards in the documentation of the EUCHNER CMS-RH-AYA-03VL: EN ISO 13849-1:2015, EN 50178:1997, EN 60204-1:2006/A1:2009, EN ISO 14119:2013, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 and EN 60947-5-3:2013. For a project in Oman or the GCC this means the read head is designed for the same safety framework as European machinery, and the designer can reference these standards in the technical file. EN ISO 14119 is particularly relevant, because it deals with interlocking devices and the measures against defeat, and a magnetically coded actuator is one of the accepted ways to lower the possibility of bypassing a guard.
Aligning head and actuator
Head and actuator must face each other, and the operating diagrams in the manual show typical operating and release distances for design A. Keep the lateral offset small, keep steel parts out of the area, and use the spacer CMS-A-SA between head and mounting surface when the surface is ferromagnetic. After mounting, move the guard slowly through its range and note the points where the LED changes and where the evaluation unit switches.
Cable handling
The encapsulated cable cannot be shortened without affecting the system, so coil any surplus neatly and fix it with clips. Keep it away from motor and frequency inverter cables, protect it where it crosses edges, and never pull on it. The wire ends are fitted with sleeves, so insert them directly into the terminals of the evaluation unit and tighten the screws with the proper torque. If a longer run is needed, the 5 m version of the same head, the CMS-RH-AYA-05VL, is the better choice than an extension.
Typical faults and checks
If the evaluation unit will not enable, first confirm that the actuator is present and correctly oriented. A steel bracket behind the head, a gap that is too large or a head that has been loosened by vibration are the usual causes. Measure the cable continuity, inspect the PVC jacket for cuts and watch the LED while moving the actuator to see whether the head reacts. If a head fails, replace it with an identical type, and consult the manual before mixing designs on one evaluation unit.
Maintenance
Keep the faces clean, check the cable for abrasion and make sure the fixings remain tight. If a head has been struck by a door, replace the pair as the magnet position may have shifted. The ambient range of minus 5 to plus 55 degrees C must be respected in outdoor use.
Ordering notes
Quote the code, the actuator CMS-MH-AA and the evaluation unit. Where cable length matters, state it clearly, since 3 m and 5 m versions have different codes.
Related items you may also need: EUCHNER RPS-M-2131SR175M Emergency Stop Rope Pull Switch | EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set | EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | All EUCHNER products.
Documents and quotation
The operating instructions for the CMS read heads and actuators are attached to this page. Please send your RFQ with EUCHNER CMS-RH-AYA-03VL, the quantity and your delivery location in Oman or the GCC.
Other Models in the Cms Range
Seven Star LLC supplies models from the Cms range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER CMS-E-ER Evaluation Unit for CMS Read Heads | Safety Switches & Guard Locking | View details |
| EUCHNER CMS-RH-AYA-03VL Magnetic Read Head, 3 m Cable | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER CMS-RH-AYA-03VL Magnetic Read Head, 3 m Cable Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER CMS-RH-AYA-03VL Magnetic Read Head, 3 m
Answers from our engineering team on installation, compatibility and integration.
01What cable length does the EUCHNER CMS-RH-AYA-03VL have?
It has a hard-wired, encapsulated PVC cable of 3 m with 0.25 square mm conductors and end sleeves.
02Is the actuator included with the EUCHNER CMS-RH-AYA-03VL?
No. The actuator, for example the CMS-MH-AA, must be ordered separately.
03What is the safe switch-off distance of the CMS-RH-AYA-03VL?
The safe switch-off distance is 20 mm, and the safe switching distance is at least 10 mm at zero centre offset without ferromagnetic material nearby.
04How does the CMS-RH-AYA-03VL differ from the CMS-RH-BYB-03VL?
The AYA is design A at 87.5 x 25 mm, while the BYB is design B, a smaller 36 x 26 mm cube.
05With which evaluation units does the CMS-RH-AYA-03VL work?
The data name the evaluation units CMS-E-ER and CMS-E-FR for read heads with Hall sensors.