- Automation & ControlView all 3,071 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER STA1A-4131A024M Guard Locking Safety Switch
Description
Overview
This guard-locking safety switch fits plants that still wire doors with cable glands rather than plugs. The EUCHNER STA1A-4131A024M has a die-cast alloy housing, three M20 x 1.5 cable entries, a spring-applied lock with a 24 V release solenoid and a contact set with no door position contact. It is therefore a clean choice where the door position is monitored by a second device, for example a separate coded sensor, and the guard locking function is wanted in its own robust housing. Seven Star LLC is an independent supplier serving Oman and the GCC.
Decoding STA1A-4131A024M
STA marks the metal guard locking switch. The 1 stands for cable-entry connection, A for the head design, and 4131 for the contact arrangement: the manufacturer lists no door position contacts, two positively driven guard lock monitoring contacts and one normally open guard lock contact. A024 gives the 24 V solenoid and M the thread of the cable entries. The article number is 096439.
Datasheet summary of EUCHNER STA1A-4131A024M
| Item | Data |
|---|---|
| Housing | Die-cast alloy, IP67 |
| Locking principle | Closed-circuit current, power to unlock |
| Solenoid | 24 V AC/DC, minus 15 to plus 10 percent, 100 percent duty, 8 W |
| Locking force | 3000 N maximum; 2300 N F Zh |
| Contacts | No door contacts; lock monitoring 2 positively driven plus 1 NO |
| Ratings | AC-15 4 A 230 V; DC-13 4 A 24 V; fuse up to 4 A gG |
| Insulation / impulse | 250 V / 2.5 kV |
| Entries | 3 x M20 x 1.5; conductor 0.34 to 1.5 square mm |
| Forces | Actuating 35 N, extraction 30 N, retention 20 N |
| Actuation frequency | up to 1200 per hour |
| Mechanical life | 1 million cycles |
| Temperature | minus 20 to plus 80 degrees C operating; minus 25 to plus 80 degrees C storage |
| B10D lock monitoring / mission | 11.5 million / 20 years |
How EUCHNER STA1A-4131A024M differs from other STA variants
Place it beside the STA3A-2131A024L024RC18, which uses an RC18 plug, adds LEDs and has a door position contact. The EUCHNER STA1A-4131A024M is a cable-gland switch without a door contact and without LEDs, with IP67 instead of IP65 and with wider temperature limits of up to 80 degrees C. The STA2A-4131A024M keeps the same contacts but applies the open-circuit current principle, meaning the lock engages when power is applied. The STA1A also has a larger insulation voltage of 250 V against 50 V on the plug version.
Guard locking in practice
When the solenoid is de-energised, the spring drives the bolt into the actuator and holds it with 3000 N. An external command, normally given after a stop-time or standstill check, powers the solenoid and releases the door. If the supply fails the door stays locked, so every installation needs an auxiliary release for rescue. The EUCHNER STA1A-4131A024M has one fitted, and it should be sealed so that it is used only in emergencies.
Applications
This type suits machines where door position is already monitored by another device or by a safety controller with separate sensors. Common examples are mixers, tumbling drums, centrifuges and large guarded cells in food, chemical and cement production, plus packaging and printing machinery in the Gulf. The wide temperature range and IP67 housing handle hot sites and washdown.
Installation notes
Rotate the head to the required approach direction, mount on a rigid surface and fit the actuator without side load. Route the solenoid supply and the three monitoring contacts through separate cable entries if possible, and seal any unused entry. Use cable glands with the correct thread, and keep conductors between 0.34 and 1.5 square mm. With ACTUATOR-S-GT-SN the overtravel is 5 mm for doors with rubber stops.
Commissioning and testing
Check that the bolt locks when power is off and releases when the solenoid is powered. Try to pull the closed door in the locked state, and check the monitoring contacts in each state. Test the auxiliary release and reseal it, then record the results.
Reliability data and release control
For guard lock monitoring the manufacturer states a B10D value of 11.5 million cycles and a mission time of 20 years, measured at DC-13 with 100 mA at 24 V. The control of the guard locking depends on the external circuit, and the designer must assess the way in which the unlock command is generated, for instance by a standstill monitor or an adjustable time delay, as part of the safety function. The solenoid needs 8 W at a duty cycle of 100 percent, so total the demand of every lock on the same machine when sizing the supply, and keep the voltage within minus 15 to plus 10 percent of 24 V.
Two positively driven contacts confirm that the bolt is locked, and they are normally brought to two safety inputs. The extra normally open contact is available for signalling.
Replacement tips
If the switch replaces an older metal guard locking unit, compare the locking principle first, because swapping a closed-circuit unit for an open-circuit unit changes the behaviour of the door at power loss. Then compare the contact set, the cable entry thread and the solenoid voltage. The STA keeps the footprint of the TP and STP designs, which often avoids drilling new holes. Fit new actuators at the same time, and transfer the seal of the auxiliary release.
Maintenance
With only 1 million mechanical cycles the lifetime is shorter than that of many position switches, so track door openings. Examine the actuator tip and the bolt for wear, inspect the housing for cracks and look at the cable glands. Replace the switch if the locking force seems reduced.
Ordering notes for EUCHNER STA1A-4131A024M
Give the complete code and mention the actuator. Because the STA family has many similar codes, confirm the locking principle, the connection and whether a door contact is needed before ordering. We can quote spare actuators and glands together.
Related items you may also need: EUCHNER ESM-BA301 Safety Relay | EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | EUCHNER CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety Switch | All EUCHNER products.
Documents and quotation
The operating instructions for the STA safety switch are attached to this page. Please send your RFQ with EUCHNER STA1A-4131A024M, the quantity and the delivery destination in Oman or the GCC.
Other Models in the Sta Range
Seven Star LLC supplies models from the Sta range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER STA3A-2131A024L024RC18 Guard Locking Safety Switch | Safety Switches & Guard Locking | View details |
| EUCHNER STA1A-4131A024M Guard Locking Safety Switch | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER STA1A-4131A024M Guard Locking Safety Switch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER STA1A-4131A024M Guard Locking Safety Switch
Answers from our engineering team on installation, compatibility and integration.
01Does the EUCHNER STA1A-4131A024M have a door position contact?
No. The manufacturer lists it without door position contacts, with two positively driven and one normally open guard lock monitoring contact.
02What locking principle does the EUCHNER STA1A-4131A024M use?
It uses the closed-circuit current principle: spring force locks the guard and the 24 V solenoid must be powered to release it.
03How many cable entries does the STA1A-4131A024M have?
It has three M20 x 1.5 cable entries in an IP67 die-cast alloy housing.
04How does the STA1A-4131A024M differ from the STA2A-4131A024M?
The STA2A uses the open-circuit current principle, locking when the solenoid is powered, while the STA1A locks by spring and unlocks with power.
05What locking force does the STA1A-4131A024M give?
The manufacturer specifies a maximum locking force of 3000 N and an F Zh value of 2300 N.