Brand:

EUCHNER CES-I-BP-U-C07-SB Compact RFID Safety Switch

Description

Overview

Few safety sensors are as small as the EUCHNER CES-I-BP-U-C07-SB. It is an RFID-coded switch measuring only 40 x 26.5 x 18 mm, with a plastic PBT-PC housing, an M12 5-pin connector and protection up to IP69K. Unicode coding ties it to one actuator, two semiconductor safety outputs report the door state, and the SB part of the code adds a door position monitoring output for a standard controller. It reaches category 4 and PL e from a single compact body. Seven Star LLC is an independent supplier serving Oman and the GCC.

How to read EUCHNER CES-I-BP-U-C07-SB

CES-I-BP is the compact RFID switch family with a plug connector. U selects unicode coding, as opposed to the M of the multicode version. C07 is the design with the small housing, and SB identifies the version with a door position monitoring output, while SI is the version for connection to decentralized peripheral systems. The manufacturer lists the article number as 160080. The actuator is separate; the series lists CES-A-BTN-C07 and A-C11-01 as suitable types.

Key technical facts for EUCHNER CES-I-BP-U-C07-SB

Characteristic Value
Coding Unicode (RFID)
Safety classification Category 4, PL e, SIL CL 3, PFH 6 x 10 to the minus 10
Supply 24 V DC, plus or minus 15 percent, 40 mA
Safety outputs FO1A / FO1B p-switching semiconductor, 1 to 150 mA, DC-13 24 V
Monitoring output OD/C 1 to 50 mA
Discrepancy time up to 10 ms
Turn-on time / risk time up to 100 ms / up to 125 ms
Ready delay 5 s
Connection M12, 5-pin, tightening torque up to 0.8 Nm
Dimensions 40 x 26.5 x 18 mm
Housing Plastic PBT-PC-GF30
Protection IP65 / IP67 / IP69 / IP69K
Ambient minus 25 to plus 55 degrees C (plus 65 at up to 10 mA per output)
Altitude up to 4000 m
Spacing between switches at least 50 mm
Mission time 20 years

How EUCHNER CES-I-BP-U-C07-SB differs from other CES-I-BP codes

The family has four codes. CES-I-BP-M-C07-SB-160076 is the multicode twin of this switch and accepts any suitable actuator. The two SI types, CES-I-BP-U-C07-SI-162815 and the multicode CES-I-BP-M-C07-SI-162813, leave pin 5 unused so that they can be connected to decentralized peripheral systems, whereas the SB types are the ones listed with a door position monitoring output. The EUCHNER CES-I-BP-U-C07-SB therefore combines unicode coding with the door monitoring signal, which is the most common request on machines with a PLC.

Sensing distances and mounting

With actuator A-C11-01 the switch-on distance is 5 mm in installation position B and 6.5 mm in position A on steel, the secured switch-off distance is at most 13 mm, and the secured switching distance is at least 3 mm or 2 mm depending on position. With actuator CES-A-BTN-C07 the switch-on distance is 7 mm in positions C and D. Surface mounting on metal is specified, and switches should be at least 50 mm apart. Caps are included to cover the fixing holes.

Where compact RFID switches are used in Oman and the GCC

Because of IP69K protection, this switch survives high-pressure hot-water cleaning, which makes it ideal for food, beverage, dairy and poultry plants and for packaging machines. It is equally useful on small guards of laboratory equipment, 3D printers and compact robotic cells where a large switch will not fit. Dust, vibration and temperature swings seldom bother a transponder switch, as no contact wears.

Connecting the switch

Use a regulated 24 V DC supply with an external fuse of 0.25 to 8 A. Safety outputs must be evaluated in both channels. When the outputs carry inductive loads, add a free-wheeling diode. The off-state current is below 0.25 mA and the test pulse lasts 0.3 ms about every 100 ms; the connected controller must tolerate those pulses. After power-up, wait the 5 s ready delay before expecting the safety outputs to be on.

Commissioning steps

Mount the switch and actuator, teach in the actuator according to the manual, and check the LED indicators. Open the guard, confirm that the outputs drop within the risk time of 125 ms, close it again and observe the monitoring output. Document the teach-in, and keep the actuator serial number with the machine records.

Safety calculation data

The manufacturer documents category 4, PL e and SIL CL 3 for the monitoring function of the EUCHNER CES-I-BP-U-C07-SB, with a PFH of 6 x 10 to the minus 10 per hour and a mission time of 20 years. That PFH is lower than that of many larger switches in the same company range, which leaves more of the budget to the logic and the actuators of the whole safety function. The two outputs FO1A and FO1B are p-switching and short-circuit proof, with a discrepancy time of up to 10 ms, so the controller can detect a one-sided failure quickly.

Choose cables and shielding with care. A compact device with an M12 plug is often placed on a moving guard, and a cable that flexes thousands of times needs a suitable, flexible type with strain relief. Keep the safety cable apart from motor leads, and avoid sharp bends at the connector. When two or more switches are placed on neighbouring doors, respect the minimum distance of 50 mm so that the coded fields do not interfere with each other.

Cleaning environments and chemical exposure

IP69K means the housing withstands close-range, high-pressure, high-temperature jets, the typical test for food plant washdown. The plastic PBT-PC-GF30 body resists many cleaning chemicals, but check compatibility with your sanitiser and keep the contact time short. After cleaning, look at the plug connector, because trapped water behind a loosely tightened connector is the most frequent cause of trouble on washdown machines. Tighten it to the specified maximum of 0.8 Nm and not beyond.

Service and diagnostics

Inspect the plastic faces for damage, clean them with a soft cloth and confirm the M12 connector is tight. A cracked body must be replaced because the sealing class is then lost. The device is not repairable, but the compact size makes spares easy to hold.

Ordering notes

Give the full code and indicate which actuator you want. Mention if a ready-made M12 cable is required, since a cable is not part of the switch. Seven Star LLC can quote the unit and spare actuators for projects across Oman.

Related items you may also need: EUCHNER ESM-BA301 Safety Relay | EUCHNER CTM-LBI-BP-U-AZ-SA BiState Guard Locking Switch | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | All EUCHNER products.

Documents and quotation

The operating instructions for the CES-I-BP switch are attached to this page. Send your RFQ with EUCHNER CES-I-BP-U-C07-SB, the quantity and the delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet EUCHNER CES-I-BP-U-C07-SB Compact RFID Safety Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CES-I-BP-U-C07-SB Compact RFID Safety Switch

Answers from our engineering team on installation, compatibility and integration.

01How small is the EUCHNER CES-I-BP-U-C07-SB?
It measures only 40 x 26.5 x 18 mm and has a plastic PBT-PC-GF30 housing with an M12 5-pin plug connector.
02What safety rating does the EUCHNER CES-I-BP-U-C07-SB reach?
It is Category 4, PL e and SIL CL 3, with a PFH of 6 x 10 to the minus 10 and a mission time of 20 years.
03What does SB mean in CES-I-BP-U-C07-SB?
SB marks the version with a door position monitoring output. The SI versions instead keep pin 5 free for decentralized peripheral systems.
04What protection rating does the CES-I-BP-U-C07-SB have?
It is rated IP65, IP67, IP69 and IP69K, which allows high-pressure hot-water cleaning.
05Which actuators work with the CES-I-BP-U-C07-SB?
The manufacturer data name the actuators A-C11-01 and CES-A-BTN-C07. The actuator is not included with the switch.