Brand: Autonics
Autonics TK4H-24CN 48×96 PID Controller Current SSR Output
Description
Overview
Vertical panel space is often easier to find than horizontal space, and the Autonics TK4H-24CN is built for that situation: a 48 x 96 mm DIN controller, taller than wide, with stacked red and green four-digit displays. Its control output can be set to a 4 to 20 mA or 0 to 20 mA current signal or to an SSR drive voltage, and it provides two alarm relays. It is a flexible PID controller for loops that drive thyristor units, SSRs or proportional valves. Seven Star LLC is an independent supplier serving Oman and the GCC.
Meaning of the code Autonics TK4H-24CN
TK4 is the four-digit series and H is the 48 x 96 mm size. The first digit after the dash, 2, selects alarm 1 plus alarm 2 as the option outputs, which adds a second relay to the standard one. The next digit, 4, is the 100 to 240 V AC supply. C is the output 1 choice that can be set to current or SSR drive, and the last letter N shows that there is no second control output. The controller therefore controls one actuator, with two alarm relays alongside it.
Specifications of Autonics TK4H-24CN
| Item | Data |
|---|---|
| Front size | 48 x 96 mm, cut-out 45 x 92 mm |
| Supply | 100 to 240 V AC 50/60 Hz, 8 VA or less |
| OUT1 | Selectable: DC 4-20 mA or 0-20 mA (load up to 500 ohm) or SSR drive 11 V DC plus or minus 2 V, up to 20 mA |
| Alarms | AL1 and AL2, relay 250 V AC 3 A, 1a |
| Thermocouple inputs | K, J, E, T, B, R, S, N, C, G, L, U and Platinel II |
| RTD inputs | Cu50, Cu100, JPt100, DPt50, DPt100, Nickel120 |
| Analog inputs | 0-10 V, 0-5 V, 1-5 V, 0-100 mV, 0-20 mA, 4-20 mA |
| Sampling period | 50 ms |
| Control modes | ON/OFF, P, PI, PD, PID; heating, cooling or heating and cooling |
| Display accuracy | PV plus or minus 0.3 percent or plus or minus 1 degree C, whichever is greater, plus 1 digit, at 23 degrees C plus or minus 5 |
| Control cycle | 1.0 to 120.0 seconds for the current or SSR output |
| Alarm relay life | 5 million mechanical operations (H size) |
| Dielectric strength | 3,000 V AC for 1 minute (AC type) |
| Ambient | minus 10 to plus 50 degrees C |
| Protection | IP65 front |
| Weight | about 141 g, about 211 g packaged |
How the Autonics TK4H-24CN differs from other TK4H variants
A TK4H with R in the output position would drive a relay with 250 V AC 3 A contacts and a minimum cycle of 0.1 seconds, while this C code can drive an SSR or give an analog 4 to 20 mA command to a phase angle power controller, with a minimum cycle of 1.0 second for the SSR mode. The digit 2 places two alarms in the case, but the 1 variant has only one. Choose the options R, T, A, B or D if you need a transmission output, RS485, a transmission output with both alarms, or digital inputs. Power supply code 2 would replace 100 to 240 V AC with 24 V AC or 24 to 48 V DC.
Current or SSR output explained
An SSR drive output provides a voltage of about 11 V DC at up to 20 mA to switch a solid state relay on and off in time proportion, with a cycle from 1.0 to 120.0 seconds. The current output, in contrast, gives a continuous signal, 4 to 20 mA or 0 to 20 mA, selectable in a parameter, and it can feed a thyristor power regulator, a proportional valve or a variable output heater controller, with a load resistance of 500 ohm or less. The selection means that a single stocked code can serve both kinds of final element, which eases spare parts planning.
Applications
This format often appears in furnace and oven panels, extrusion lines, drying equipment, and boiler and oil heating skids, where two alarm relays are used for high temperature warning and over-temperature trip. In Oman and the GCC, vertical controllers are common on panels with a column of instruments. With IP65 front protection they withstand dusty and wet surroundings, within the ambient limits of minus 10 to plus 50 degrees C.
Accuracy and input ranges worth checking for the Autonics TK4H-24CN
The display accuracy at room temperature, 23 degrees C plus or minus 5, is the process value plus or minus 0.3 percent or plus or minus 1 degree C, whichever is greater, plus one digit. Outside the room temperature range it widens to plus or minus 0.5 percent or 2 degrees C. For thermocouples K, J, T, N and E below minus 100 degrees C, and for L, U, Platinel II and the RTD types Cu50 and DPt50, the figure becomes 0.3 percent or 2 degrees C, and for thermocouples R, S, C and G the allowance grows to 3 degrees C below 200 degrees C. Thermocouple B has no accuracy standard below 400 degrees C. Analog inputs are accurate to 0.3 percent of full scale plus one digit at room temperature.
The usable ranges are generous: thermocouple K covers minus 200 to 1,350 degrees C, J covers minus 200 to 800 degrees C, T minus 200 to 400 degrees C, N minus 200 to 1,300 degrees C, and R and S 0 to 1,750 degrees C. Pt100 types reach minus 200 to 650 degrees C, and Cu50 and Cu100 read minus 199.9 to 200.0 degrees C. When the decimal point display is selected, some parameter ranges are limited, so choose the resolution that matches the process. Fahrenheit displays are available through a parameter as well.
Pick the sensor and wire it correctly before judging the controller: a thermocouple needs matching compensating cable up to the terminals, and an RTD needs three equal conductors with a line resistance of 5 ohm or less per line.
Wiring and mounting
Cut out a 45 x 92 mm opening, insert the controller and fasten the bracket. Use AWG 20 or heavier wire for the supply and relays, tighten the terminals to 0.74 to 0.90 N m and keep sensor leads apart from power wires. The digital input of other models is not electrically isolated from internal circuits, so isolate it when connecting other circuits. Use a thermal fuse or independent high limit device on safety-critical heaters, since the alarm relay of any controller is not a replacement for safety hardware.
Commissioning
Select the sensor type and range first, then the unit, control mode and output type, and run auto tuning at the working setpoint. The AT lamp flashes every second during tuning. Set AL1 as a deviation or absolute alarm for process warning, and AL2 for a higher trip level. With current output, check that the actuator responds at 4 mA and 20 mA end points.
Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | Omron E3Z-D61 Photoelectric Sensor 100 mm diffuse | SICK WL12L-2B530 Laser Retro-Reflective Sensor, 18 m | All Autonics products.
Documents and quotation
The TK series product manual covering the Autonics TK4H-24CN is attached, with the ordering code table, input ranges, connection diagrams and cut-out dimensions. Send an RFQ with the part number Autonics TK4H-24CN, quantity and delivery location in Oman or the GCC.
Other Models in the TK Range
Seven Star LLC supplies models from the TK range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Autonics TK4S-14RN PID Temperature Controller 48×48 mm | Controllers & Data Acquisition | View details |
| Autonics TK4M-14RN 72×72 PID Temperature Controller Relay | Photoelectric Sensors | View details |
| Autonics TK4S-14RR 48×48 Heating Cooling PID Controller | Photoelectric Sensors | View details |
| Autonics TK4H-24CN 48×96 PID Controller Current SSR Output | Photoelectric Sensors | You are viewing this model |
Datasheets & Documents
- Datasheet Autonics TK4H-24CN 48x96 PID Controller Current SSR Output Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.
Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.
Autonics company profile
| Founded | 1977, South Korea |
|---|---|
| Current name | Autonics, since 1988 |
| Headquarters | Busan, South Korea |
| Factories | Busan and Yangsan |
| Product families | E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers |
Milestones
- 1977: The company is founded.
- 1988: Renamed Autonics Corporation.
- 2014: Opens its Busan headquarters.
Reading the Autonics E40S encoder code
E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.
Where Autonics encoders are used
Servo and spindle feedback, conveyor length measurement, packaging and printing machines.
Ordering Autonics encoders: what we need
Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.
Facts checked against Autonics corporate profiles, October 2026.
Browse Autonics products by category: Encoders.
FAQ
Questions about the Autonics TK4H-24CN 48×96 PID Controller Current SSR
Answers from our engineering team on installation, compatibility and integration.
01What does the C mean in Autonics TK4H-24CN?
C marks output 1 as selectable current or SSR drive, so a parameter chooses 4-20 mA or 0-20 mA current, or a voltage drive for a solid state relay.
02How many alarm outputs does the Autonics TK4H-24CN have?
The option digit 2 gives alarm 1 plus alarm 2, both relay outputs rated 250 V AC 3 A, 1a.
03What size is the Autonics TK4H-24CN?
It is a vertical 48 x 96 mm DIN controller needing a 45 x 92 mm panel cut-out, with a weight of about 141 g.
04What supply does the Autonics TK4H-24CN use?
The digit 4 indicates 100 to 240 V AC at 50/60 Hz, with a power consumption of 8 VA or less.
05Which load resistance can the current output of the Autonics TK4H-24CN drive?
The 4-20 mA or 0-20 mA output is rated for a load resistance of 500 ohm or less.