Brand:

Bürkert 020033 Type 0255 Brass FKM Solenoid Valve 24V AC

Description

Overview

For hot air, oils and per-solutions in compact lines, Bürkert 020033 is a practical choice. It is a Bürkert Type 0255 direct-acting 2/2-way solenoid valve with a brass body, G¼ port, 2.0 mm orifice, water Kv value of 0.12 m3/h and an FKM seal, ordered for 24 V at 50 Hz. Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical data of Bürkert 020033

Parameter Value
Article 020033, brass body, G 1/4
Orifice and Kv 2.0 mm, 0.12 m3/h
Seal FKM
Voltage 24 V 50 Hz
Pressure, liquids on AC 0 to 35 bar
Pressure, gases on AC 0 to 60 bar
Medium temperature minus 10 to plus 130 degrees C with FKM
Family Bürkert Type 0255, direct-acting 2/2-way plunger valve
Circuit function A, normally closed
Coil Epoxy, thermal class H, tolerance plus or minus 10 percent
Duty cycle 100 percent
Switching AC open 10 to 20 ms, close 20 to 30 ms
Switching DC open 20 to 80 ms, close 20 to 30 ms
Seat Stainless steel 1.4305
Viscosity max. 21 mm2/s
Ambient max. plus 55 degrees C
Electrical connection Form A, DIN EN 175301-803, cable plug Type 2518 supplied
Protection IP65 with cable plug

Why Bürkert 020033 is an AC version

An AC coil lifts the plunger harder than a DC coil, which is why the same 2.0 mm orifice is rated for 35 bar on liquids and 60 bar on gases with AC, while the DC version of the same row (article 089888) is rated for 20 bar. The cost is an inrush of about 35 to 40 VA and a hold of 16 VA, with 10 W real power, so AC valves run warmer than the low-power DC alternatives. A 24 V 50 Hz supply is common on machine control transformers.

How Bürkert 020033 differs from other Type 0255 articles

Against 058360, which has a 1.0 mm orifice and a PTFE seal, 020033 doubles the orifice, raises Kv from 0.03 to 0.12 m3/h, and uses FKM. Against the 3.0 mm article 058421 it has less flow but a higher pressure rating. The FKM seal gives better sealing at low pressure and covers hot air and oils, but it is not suited to steam or solvents, for which the PTFE articles are better.

Seal choice: FKM against PTFE

FKM seals suit hot air, hot oils, oils with additives and per-solutions between minus 10 and plus 130 degrees C. PTFE seals extend the medium range to water, steam, fuels, hydraulic fluids, alcohol, organic solvents and waste gas, between minus 40 and plus 180 degrees C. Stainless steel seat versions can reach plus 210 degrees C on request. PTFE flows under load, so for the highest tightness at low pressure FKM can be better, while PTFE wins on chemical resistance and temperature. Always check the full article against the process data before ordering.

Safety and failure behaviour

The valve is normally closed, so loss of power closes it, which is the usual safe state for fuel, steam and hydraulic lines. A direct-acting valve can still leak slightly through the seat, especially with FKM after long service or with dirt on the seat, so it should not be the only barrier where a leak-tight isolation is a safety requirement. Combine it with a block valve where necessary, and test the closing function periodically on critical lines, noting the date and the result in the maintenance records.

Working with AC coils on Bürkert 020033

AC coils start with a large inrush and then settle at a lower holding current once the plunger is closed in. If the plunger sticks, the current stays high and the coil can burn out within minutes, which is why dirt in the orifice or a mechanically blocked valve is a serious risk on AC coils. Switching time is quick, with 10 to 20 ms opening and 20 to 30 ms closing, which is faster than the DC opening time of 20 to 80 ms. For short cycle dosing at 24 V 50 Hz this speed is a real advantage.

Use a fuse or thermal protection on the supply to the valve, because an AC coil with a blocked core overheats faster than a DC one.

Typical hot air and oil uses for Bürkert 020033

The FKM seal and the 2.0 mm orifice suit hot air lines for dryers and ovens, burner pilot lines, lubricating oil circuits and pneumatic control of heat treatment equipment. The temperature limit of plus 130 degrees C with FKM is the main constraint. For steam above that temperature, a PTFE version with a stainless seat is the proper choice, while hot oil up to 130 degrees C is the sweet spot for this article.

Selection checks for Bürkert 020033

Confirm the supply is 24 V at 50 Hz and not 60 Hz, which would need a coil marked for that frequency. Check medium temperature against the FKM limit and confirm that the medium contains no steam or aggressive solvents. Compare the pressure with the AC columns of the ordering chart, 35 bar for liquids and 60 bar for gases. If the line is below one bar, a direct-acting valve of this size is still fine because no differential is required.

Because the cable plug is part of the delivery, no extra plug is needed, but spare plugs are cheap and worth stocking for maintenance in plants with many valves.

Related items for the Bürkert 020033 installation

Hot air and oil lines using this valve often also need strainers, temperature gauges, check valves and cable plugs. Provide the line size and medium in the enquiry. For heat-treatment and drying equipment, note the maximum surface temperature near the coil and shield it if necessary, since the coil insulation class H tolerates heat but nearby cables may not. Keep an eye on thermal expansion of the line near the brass body.

Installation steps for Bürkert 020033

Isolate and depressurise the line, thread the G¼ port with sealant suited to oil or hot air, orient the coil upright where possible, connect the supplied cable plug and tighten it. Energise for a test while the line is at low pressure, listen for the switching click, then raise pressure slowly and check the thread for leaks. Mark the date and article number on the maintenance record.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Festo MFH-5-1/8-S-B Solenoid valve | All Bürkert products.

Documents and quotation

The Type 0255 data sheet that covers Bürkert 020033 is attached with ordering charts, power data and dimensions. Please send an RFQ with part number 020033, the quantity and your delivery location in Oman or the GCC.

Other Models in the 0255 Range

Seven Star LLC supplies models from the 0255 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 058360 Type 0255 Brass 100 bar Solenoid ValveSolenoid ValvesView details
Bürkert 020033 Type 0255 Brass FKM Solenoid Valve 24V ACSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 020033 Type 0255 Brass FKM Solenoid Valve 24V AC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 020033 Type 0255 Brass FKM Solenoid Valve

Answers from our engineering team on installation, compatibility and integration.

01What voltage is Bürkert 020033?
It is the 24 V 50 Hz AC version of the 2.0 mm G 1/4 brass valve with an FKM seal.
02What pressure does 020033 cover?
On an AC coil the chart lists 0 to 35 bar for liquids and 0 to 60 bar for gases.
03What is the Kv value of Bürkert 020033?
The water Kv value is 0.12 m3/h with a 2.0 mm orifice.
04Which media suit 020033 with its FKM seal?
FKM suits hot air, hot oils, oils with additives and per-solutions between minus 10 and plus 130 degrees C.
05Does 020033 include a cable plug?
Yes, the Type 0255 data sheet states that cable plug Type 2518 is supplied as standard.