Brand:

Autonics E30S4-1000-3-N-5 30 mm Incremental Rotary Encoder

Description

Overview

Space is often the deciding factor when a feedback device is chosen, and Autonics E30S4-1000-3-N-5 is a compact answer, with a body diameter of only 30 mm and a 4 mm solid shaft. It belongs to the E30S Series of incremental rotary encoders. The model code reads: S is the shaft type, 4 is the shaft diameter in millimetres, 1000 is the resolution in pulses per revolution, 3 means output phases A, B and Z, N means an NPN open collector output, and 5 selects a 5 V DC supply. Seven Star LLC is an independent supplier serving Oman and the GCC.

The unit is a light component of roughly 80 g that fits small motors, printers, labelling machines, dosing pumps and laboratory instruments.

Why choose Autonics E30S4-1000-3-N-5

  • 30 mm outer diameter with a 4 mm shaft, ideal for compact machines.
  • 1000 PPR resolution, with the series available in 100, 200, 360, 500, 1,000, 1,024 and 3,000 PPR.
  • NPN open collector output with a sink current of 30 mA and residual voltage of 0.4 V DC or less.
  • 5 V DC plus or minus 5 percent supply with a current consumption of 80 mA or less without load.
  • Maximum response frequency of 300 kHz.
  • Low starting torque of 0.002 N m or less and inertia of 20 g cm2 or less.

Technical data of Autonics E30S4-1000-3-N-5

Parameter Value
Model E30S4-1000-3-N-5
Outer diameter 30 mm
Shaft diameter 4 mm solid shaft
Resolution 1000 PPR
Output phases A, B, Z
Control output NPN open collector
Power supply 5 V DC plus or minus 5 percent, ripple 5 percent or less
Current consumption 80 mA or less (no load)
Max. response frequency 300 kHz
Starting torque 0.002 N m or less
Inertia moment 20 g cm2 or less
Allowable shaft load radial 2 kgf, thrust 1 kgf
Insulation / dielectric 100 megohm at 500 V DC; 750 V AC for 1 minute
Vibration / shock 1 mm, 10 to 55 Hz, 2 hours / 50 G or less
Ambient temperature minus 10 to plus 70 degrees C
Protection IP50
Cable 5 mm, 5-wire, shielded, 2 m, AWG24
Weight approx. 80 g

How E30S4-1000-3-N-5 differs from other E30S variants

Four things distinguish a code in this series. The resolution can be changed to any of seven values. The control output can be totem-pole (T), NPN open collector (N), voltage (V) or line driver (L); line driver models are 6-phase and use a 9-pin plug. The power supply code 5 gives 5 V DC for the N and L types, while 12 to 24 V DC models exist for T, N and V outputs. And the connection can be an axial cable, an axial cable connector or a connector type.

Compared with the 50 mm E50S, Autonics E30S4-1000-3-N-5 is lighter (80 g against 275 g), has lower starting torque (0.002 against 0.007 N m) but also lower shaft load capacity (radial 2 kgf against 10 kgf), so it should not take the side load of a belt drive.

Applications

Typical uses in Oman and the GCC include small servo and stepper axes, tension and length measurement on printing and labelling machines, dosing and metering pumps, laboratory automation and compact conveyors. A 1000 PPR resolution gives 4000 counts per revolution when a controller counts all four edges.

Selection and compatibility notes

The 5 V supply must be regulated: if only 24 V is available, choose the 12 to 24 V version of the series rather than a dropper resistor. NPN open collector needs a pull-up in the receiver, so check that the counter supports sinking inputs. A rated 4 mm flexible coupling is advised because the manual warns that misalignment and direct shaft loads reduce encoder life.

Installation and commissioning

Fix the encoder with the bolts included, couple the shaft with a flexible coupling, and keep tightening torque on any coupling wrench to 0.5 N m or less. Wire black to A, white to B, orange to Z, brown to plus supply and blue to ground, with the shield grounded. Rotate the shaft clockwise facing it and confirm that the A channel leads B on Autonics E30S4-1000-3-N-5. Pulling on the cable above 30 N must be avoided.

Signal behaviour and electrical notes

With an NPN open collector output, each of the three channels pulls its line to ground when active and leaves it floating when inactive, so the receiving counter, PLC card or drive must supply the pull-up, normally to the same 5 V as the encoder or a higher level within the output rating. The sink current is limited to 30 mA per channel and the residual voltage is 0.4 V DC or less, which gives a clean low level to most logic inputs. Response speed is stated as 1 microsecond or less, and the maximum response frequency is 300 kHz, so at 1000 PPR the electronics could follow far more than the shaft will ever deliver. When the cable is extended, the manual warns that line resistance and capacitance raise the residual voltage and slow the response, so keep the cable short or use shielded twisted pairs with a line driver version for long runs.

Maintenance

Inspect the coupling and cable regularly, keep the encoder free of oil and dust ingress beyond the IP50 rating, and replace the unit if pulses are missing or the signal is unstable.

Ordering notes for Autonics E30S4-1000-3-N-5

Quote E30S4-1000-3-N-5 and the quantity. Tell us if you need a different resolution, a totem-pole or line-driver output or a 12 to 24 V DC model.

Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | SICK DBS50E-S5AK02000 DBS36/50 Encoder | Omron E6B2-CWZ6C Incremental Rotary Encoder 1,000 P/R | All Autonics products.

Documents and quotation

The E30S Series product manual is attached to this listing. To request pricing, send part number E30S4-1000-3-N-5, the quantity and your delivery location in Oman or the GCC through the RFQ form and we will confirm availability and lead time.

Datasheets & Documents
  • PDF Datasheet Autonics E30S4-1000-3-N-5 30 mm Incremental Rotary Encoder Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics E30S4-1000-3-N-5 30 mm Incremental Rotary

Answers from our engineering team on installation, compatibility and integration.

01What does E30S4-1000-3-N-5 mean?
30 mm shaft encoder, 4 mm shaft, 1000 PPR, A/B/Z outputs, NPN open collector output and 5 V DC supply.
02What supply voltage does it need?
5 V DC plus or minus 5 percent with a ripple of 5 percent or less and a current consumption up to 80 mA without load.
03What shaft loads are allowed?
The manual gives radial 2 kgf and thrust 1 kgf, so use a flexible coupling and avoid side loads.
04How many pulses per turn does it output?
1000 pulses per revolution on A and B, plus one Z pulse per turn.
05What is the cable?
A 5 mm, 5-wire shielded axial cable of 2 m with AWG24 conductors.