Brand:

Magnetrol B40-3C30 Carbon Steel External Cage Level Switch

Description

Overview

Magnetrol B40-3C30 is the carbon steel chamber code in the B40 high pressure float switch family, finished with a 1-1/2 inch socket weld tank connection. It gives plant owners an economical external cage for vessels that run hot but do not need stainless metallurgy, such as flash tanks, knock-out drums and receivers in dry hydrocarbon or steam condensate duty. The pivoted float and magnetic sleeve sit inside the pressure cage; the electrical switch sits outside. Seven Star LLC is an independent supplier serving Oman and the GCC.

Rating curve for Magnetrol B40-3C30

100 F (38 C) 1925 psi (132 bar)
500 F (260 C) 1820 psi (125 bar)
750 F (400 C) 1250 psi (86 bar)
800 F (427 C) 1100 psi (75 bar)
1000 F (538 C) 215 psi (14 bar)

The datasheet warns that caution should be used when specifying carbon steel above 800 F (427 C). The steep fall between 800 and 1000 F is the reason why the stainless or chrome-moly chambers exist, so check your design temperature against the table rather than the 1000 F headline for the switch family.

Magnetrol B40-3C30 specification facts

  • Chamber code 3C30, carbon steel, 1-1/2 inch socket weld
  • Minimum specific gravity 0.65
  • Stainless steel 300 series float with magnetic sleeve and tension spring return
  • Process temperature up to +1000 F (+538 C) subject to chamber rating and switch type
  • Hydrostatic test at 1.5 times design pressure
  • ASME Section IX welding, full penetration welded branches
  • Enclosure choices: Type 4X polymer-coated steel, polymer-coated aluminum with approvals, or cast iron with hazardous area approvals
  • Options: flanged connections, ASME B31.1, temperature extensions, ATEX housing, low gravity calibration, extra QC

Switch choices for the B40-3C30

Dry contact Series C, D, R and S switches and hermetically sealed Series F, HS, 8 and 9 switches are listed. At 120 VAC the non-inductive ratings are 15 A for Series C, 10 A for D, 2.5 A for F and 5 A for HS; at 24 VDC they are 6 A for C, 4 A for F and 5 A for HS. Hermetic capsules suit salt laden or corrosive air, and the HS is a positively pressurized capsule for the whole mechanism. Match the switch temperature range to the process, as the switch limit can be lower than the chamber limit. Series F is listed from -50 to +750 F.

How B40-3C30 differs from B40-4C40

Both codes share the 1-1/2 inch socket weld and the 0.65 specific gravity floor, but the metals differ. The 3C30 is carbon steel and the 4C40 is 316 stainless steel. At 100 F the 4C40 is rated 3700 psi against 1925 psi for the 3C30, and at 1000 F it still holds 3011 psi against 215 psi. Choose 3C30 where cost matters and temperatures stay below roughly 800 F; choose 4C40 for the highest pressure and temperature or where corrosion calls for stainless.

Why an external cage switch

An external cage keeps the float in a separate pressure-retaining chamber that connects to the vessel at two levels. Turbulence, foam and agitation inside the vessel are damped by the cage, so the float follows true liquid level rather than splashing. The cage can also be isolated and drained so that the switch can be tested or serviced while the vessel stays in operation, if block valves are fitted in the connecting pipework as plant practice allows.

Inside the cage the magnetic coupling does the work. A pivoted float moves a magnetic sleeve into or out of the field of the switch magnet; a barrier tube made of non-magnetic material separates the wet side from the electrical side. There is therefore no rotating shaft and no dynamic seal, which is why this construction is trusted at high pressure.

Because the chamber is welded, the pressure boundary is defined by the code stamp and weld records rather than by a gasketed joint. Welding follows ASME Section IX, branch joints are full penetration, and the chamber is hydrotested at 1.5 times design pressure before it leaves the factory.

Fit in Oman and GCC plants

Refineries, gas gathering stations, power plants and petrochemical units use external cage switches on separators, scrubbers, accumulators and storage tanks. The 3C30 suits clean condensate receivers and lube oil or seal oil drums, where a hot carbon steel vessel is already specified and the switch should match the vessel material for welding and code compliance.

Fitting and proof testing

Weld the cage to the vessel using the 1-1/2 inch socket connections, keep ambient at the switch head under +140 F (+60 C) and allow 8 inches overhead for the cover. After installation, raise and lower the level to confirm that the contacts change at the switch points and record the result in the loop file. Include the cage in the periodic inspection of the vessel, and record the as-found and as-left switch points together with the date, the technician and the instrument used, so that later proof tests can be compared against the commissioning result. If the vessel is lagged or heat traced, keep insulation clear of the switch head so that the housing stays within its ambient limit and condensation cannot collect behind the cover.

Care of the assembly

Drain and flush the cage as site practice requires, look for internal corrosion on carbon steel chambers and keep the float free of sludge. Replace damaged enclosure gaskets and keep conduit seals tight. When ordering a spare, confirm the full order code on the nameplate.

Related items you may also need: Magnetrol Echotel 961/962 Ultrasonic Level Switch | Magnetrol 089-5533-001 Stem and Spring Kit, 0.23-0.54 SG, Modulevel | Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VAC | All Magnetrol products.

Before you order the Magnetrol B40-3C30

  • To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Magnetrol B40-3C30 code on this page.
  • The quotation for the Magnetrol B40-3C30 states the confirmed code and the lead time to site.
  • The attached manufacturer datasheet covers the Magnetrol B40-3C30 ratings, dimensions and installation details.
  • Delivery of the Magnetrol B40-3C30 is arranged to project sites in Oman and across the GCC, alongside the rest of our level switches range.
  • A spare Magnetrol B40-3C30 on the shelf is a simple way to protect critical service from long lead times.

Documents and quotation

The datasheet for Magnetrol B40-3C30 is attached. Send an RFQ to Seven Star LLC with the chamber code, switch and enclosure code, any ASME B31.1 or ATEX requirement and the number of units.

Datasheets & Documents
  • PDF Datasheet Magnetrol B40-3C30 Carbon Steel External Cage Level Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol B40-3C30 Carbon Steel External Cage Level

Answers from our engineering team on installation, compatibility and integration.

01What chamber material does B40-3C30 use?
Code 3C30 is a carbon steel chamber with a 1-1/2 inch socket weld connection.
02How does pressure rating change with temperature on B40-3C30?
It is 1925 psi at 100 F, 1820 psi at 500 F, 1250 psi at 750 F, 1100 psi at 800 F and 215 psi at 1000 F.
03Is carbon steel suitable above 800 F in the B40?
The datasheet advises caution with carbon steel above 800 F (427 C) and offers stainless and chrome-moly chambers.
04What is the minimum specific gravity for B40-3C30?
The B40 family is listed for a minimum specific gravity of 0.65.
05Can B40-3C30 be supplied with ASME B31.1 construction?
ASME B31.1 construction and additional QC testing are listed as options for the B40 series.