Magnetrol Echotel 940 Ultrasonic Level Switch, Relay Output

Description

Overview

Magnetrol Echotel 940 is the relay-output member of the compact Echotel ultrasonic switch pair. Instead of shifting a loop current, it closes or opens an SPDT contact when its 316 stainless steel transducer gap changes between wet and dry. The electronics are potted just above the process fitting, and three flying leads leave the unit, which keeps the installed footprint very small. Seven Star LLC is an independent supplier serving Oman and the GCC.

Buyers usually reach for this model when the field wiring ends at a motor starter, an alarm annunciator, a pump control relay or a PLC digital input, because a dry contact can be wired straight into those devices without a barrier or analog card.

What sets the relay version apart

The relay rating is the first thing to check. The datasheet lists one amp at 30 VDC, one half amp at 125 VDC and one half amp at 150 VAC. That is enough for pilot duty, signal lamps and interposing relays, but not for direct motor loads, so a contactor or an external relay should sit between this switch and a pump.

The second difference is the safety listing: the manufacturer states that the 940 is suitable for SIL 2 loops, whereas its current shift sibling is listed for SIL 1. The third is the approval path. The relay version carries FM non-incendive marking for Class I Division 2 Groups A to D, Class II Division 2 Groups E to G and Class III, Type 4X, IP 66, T4, and is selected with agency digit 7, or digit 8 when ASME B31.3 construction and a CRN are needed.

Magnetrol Echotel 940 specification table

Model 940, compact ultrasonic level switch with SPDT relay output
Supply 12 to 35 VDC, under 1 watt
Relay contact SPDT, 1 A at 30 VDC; 0.5 A at 125 VDC; 0.5 A at 150 VAC
Transducer material 316 stainless steel, tip sensitive
Leads 18 inch (457 mm) flying leads, 18 AWG
Repeatability 0.078 inch (2 mm)
Response About 1/2 second
Process and ambient temperature -40 to +185 F (-40 to +85 C)
Pressure 2000 psig (138 bar) for 1 inch NPT or 2 inch BSP; 1500 psig (103 bar) for longer transducers
Barrel diameter 0.875 inch (22 mm)
NPT actuation length 4.13 inch (105 mm) in the dimension drawing
Tri-Clamp actuation length 3.9 inch (99 mm) in the dimension drawing
Shock and vibration ANSI/ISA-S71.03 Class SA1 and Class VC2
Approvals FM non-incendive, digits 7 or 8

Operating principle in brief

Two piezoelectric crystals face each other across a small gap at the tip. The transmit crystal is driven by the electronics, and the receive crystal turns any sound it hears back into a voltage. Liquid in the gap carries the sound across; air, vapor or foam does not. The relay follows that state, so the contact position tells you directly whether liquid covers the tip.

Since there is no float, vane or fork, nothing can jam, and no calibration or setpoint adjustment is needed. Viscous product drains from the open gap rather than clinging to it.

Choosing connection and length for Magnetrol Echotel 940

The process connection code sits in digits five and six: 11 is three-quarter inch NPT, 22 is 1 inch BSP (G1), 23 is a 1 inch 150 pound ASME raised-face flange, 33 and 43 are one and a half inch and 2 inch 150 pound flanges, and 3T and 4T are one and a half inch and 2 inch Tri-Clamp 16 AMP fittings. Everything other than code 11 needs an actuation length of at least 2 inches or 5 centimeters.

Digit seven is E for inches or M for centimeters, and digits eight to ten are the length from 1 to 100 inches or 3 to 250 centimeters. A side-mounted unit trips at the tip, so the length decides the switching height. Confirm the full order code on the nameplate whenever you are replacing an installed unit.

Where it earns its place in the Gulf

Typical jobs include high-level trips on chemical dosing tanks at desalination plants, low-level cutouts on lube oil reservoirs at compressor skids, sump alarms in pumping stations, and day tank monitoring at standby generator sites. Manufacturing plants use it on coolant sumps, hydraulic power packs and wash tanks. The compact size also suits OEM skids that must leave maintenance clearance.

The datasheet adds fill line monitoring, pump protection and leak detection between two tank walls to the use cases, and presents the unit as a practical substitute for aging floats, conductivity probes and tuning forks.

Fitting it correctly

  • Orient the tip so the gap drains when the vessel empties
  • Keep the flying leads in a junction box or conduit; an optional NEMA 4 cast aluminum junction box, number 052-7012-XXX, is listed
  • Wire the relay contact to a suitable load within its ratings and add a suppressor on inductive loads
  • Apply 12 to 35 VDC and test by wetting and drying the tip

Allow for pressure: the long transducers are rated lower than the short 1 inch NPT or 2 inch BSP ones. Stay within the +185 F process limit.

Care and spares

Check for scale or crystallized deposits across the gap during turnarounds and clean with a soft brush and a compatible solvent. Exercise the alarm path periodically, since a relay contact that never moves may hide a wiring fault. The manufacturer warrants electronic level and flow controls for eighteen months from factory shipment.

Related items you may also need: Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay | Magnetrol Z31-2849-001 Electronic Module for Eclipse 706 GWR | Magnetrol 004-8778-001 Cable Weight for Eclipse 706 7y2 Probe | All Magnetrol products.

Checklist before ordering the Magnetrol Echotel 940

  • Before ordering the Magnetrol Echotel 940, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the Magnetrol Echotel 940 code and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the Magnetrol Echotel 940 dimensions, ratings and connections.
  • The Magnetrol Echotel 940 is listed in our level switches range and ships to sites across Oman and the GCC.
  • Spare quantities of the Magnetrol Echotel 940 are worth planning for critical duty so that a failure does not stop production.

Documents and quotation

A copy of the datasheet covering Magnetrol Echotel 940 is attached here. When you send an RFQ to Seven Star LLC, state model 940, the approval digit (7 or 8), connection code, unit letter, actuation length and quantity. A photo of the nameplate of the unit being replaced is the quickest way to confirm the code.

Datasheets & Documents
  • PDF Datasheet Magnetrol Echotel 940 Ultrasonic Level Switch, Relay Output Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Echotel 940 Ultrasonic Level Switch,

Answers from our engineering team on installation, compatibility and integration.

01What contact rating does the Echotel 940 relay have?
The SPDT relay is rated 1 amp at 30 VDC, 0.5 amp at 125 VDC and 0.5 amp at 150 VAC, so use an interposing relay for motors.
02Is Echotel 940 suitable for SIL applications?
The manufacturer states the 940 is suitable for SIL 2 loops, while the 941 current shift version is listed for SIL 1.
03Which approval digit applies to Echotel 940?
Digit 7 is FM non-incendive and digit 8 adds ASME B31.3 construction with a CRN available; digits 1 and 2 belong to the 941.
04What process connections can Echotel 940 be ordered with?
Three-quarter inch NPT, 1 inch BSP, 1 to 2 inch 150 pound flanges and one and a half or 2 inch Tri-Clamp fittings are offered.
05Does Echotel 940 need calibration?
No calibration is required. The pulsed ultrasonic gap sensor simply reports wet or dry at the tip.