KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min
Description
KRACHT VCA 0.1 K5F4R1SH in brief
KRACHT VCA 0.1 K5F4R1SH is the second-smallest meter of the VCA family and the one most often chosen for general low-flow oil duties. A tooth chamber volume of 0.100 cm3, ball bearings and an aluminium housing give it a measuring range of 0.08 to 10 l/min and a pulse density of 10,000 per litre.
The code splits into VCA 0.1 (size), K (ball bearing), 5 (housing aluminium with steel gears), F (FKM seals), 4 (hard-coated surface), R (pipe connection), 1 (one sensor), S (standard pre-amplifier) and H (Hirschmann socket).
What sets VCA 0.1 K5F4R1SH apart from its siblings
The jump from VCA 0.04 to VCA 0.1 matters in three numbers. Range moves from 0.02 to 4 l/min up to 0.08 to 10 l/min; resolution falls from 25,000 to 10,000 pulses per litre; weight rises from 0.5 kg to 0.6 kg. The pressure rating stays at 240 bar.
Unlike the VCA 0.04 with stainless gears, the code 5 here means steel gears inside an aluminium housing. Compared with the VCA 0.2 (0.25 to 10 l/min, plastic plain bearing, 200 bar) the VCA 0.1 reaches lower flow because ball bearings start turning at 0.008 l/min at 20 mm2/s, but it cannot offer the second sensor channel that the VCA 0.2 provides.
Datasheet values for VCA 0.1 K5F4R1SH
| Parameter | Value |
|---|---|
| Type code | VCA 0.1 K5F4R1SH |
| Geometric tooth volume | 0.100 cm3 |
| Measuring range | 0.08 to 10 l/min |
| Measuring unit starting at | 0.008 l/min at 20 mm2/s |
| Resolution | 10,000.00 pulses per litre |
| Maximum pressure | 240 bar |
| Weight | 0.6 kg |
| Bearing | Ball bearing |
| Housing / gears | Aluminium / steel |
| Seals | FKM |
| Typical accuracy | plus/minus 1.0 percent from 20 mm2/s |
| Media and ambient temperature | -10 to 80 C |
| Viscosity | up to 4,000 mm2/s |
| Supply | 12 to 30 V DC |
| Output | PNP / NPN square wave, single channel |
| Protection | IP 65 |
Typical uses of VCA 0.1 K5F4R1SH in the Gulf region
At 10 l/min the meter fits consumption measurement on small engines and gearboxes, lubricating oil circuits of turbines and compressors, hydraulic test stands and coolant dosing in machine tools. The pulse output can be read by plant PLCs or by KRACHT display electronics such as the SD 1 or AS 8.
Oil, diesel, lubricating fluids and similar media in the viscosity range up to 4,000 mm2/s are suitable. Water-like media are not the intended duty because the gears run on the lubricating film of the medium.
Many Gulf maintenance teams also keep a small flow meter of this class on the workshop test bench. After overhaul, a gearbox or small pump can be run on the bench and its oil throughput checked against the specification before it returns to the plant. Because the VCA 0.1 reads from 0.08 l/min, it covers the low-speed point of such a test as well as the rated point, and the pulse output can be logged by a handheld counter or by a PLC test routine.
For continuous monitoring, the meter works well on grease-free oil mist and circulating lubrication lines where a loss of flow means a bearing is no longer being supplied. A low-flow alarm in the PLC, derived from the pulse frequency, is a cheap way to protect a turbine bearing or a gearbox, and a total-volume figure helps plan oil top-up and change intervals.
Selection and compatibility with VCA 0.1 K5F4R1SH
Make sure the minimum flow of the process is above 0.08 l/min, otherwise the meter operates below its specified range. Install any position; flow in either direction is permitted. Filter the line: the clearances of such a small unit are sensitive to particles.
A single channel means the meter counts volume but does not distinguish forward and reverse flow. For that function, KRACHT offers dual-channel types in the series, namely VCA 0.2 and VCG 2.
Think about viscosity at start-up as well as at operating temperature. The datasheet states the starting flow for the measuring unit at 20 mm2/s, and states that pressure drop curves depend on viscosity, so a cold, thick oil can produce a pressure loss close to the 16 bar maximum even at moderate flow. If the line cannot tolerate that loss, consider the next larger size instead of forcing a small meter to carry a big flow.
Installation and signal wiring for VCA 0.1 K5F4R1SH
Screw the pipe connection into the line, tighten as the thread requires, and connect the socket: brown pin 1 for supply, green pin 2 for the channel, white pin 4 for 0 V, pin 3 unused. Output amplitude is at least 0.8 of the supply voltage and the duty cycle is 1:1 plus/minus 15 percent.
A power budget of 0.9 W per device and 0.3 W per channel is enough for a standard 24 V DC instrument supply.
Fix the meter so that its weight of 0.6 kg does not hang on the tubing alone, and give the cable a drip loop. The hard-coated aluminium surface tolerates workshop handling, but the plug and its pre-amplifier are the most delicate part, so protect them from knocks and keep the IP 65 seal seated.
Care and service
Pressure drop rises with viscosity, so check the chart in the datasheet if the oil is cold or thick; a maximum of 16 bar loss is permitted. If you find rising pressure drop at constant flow, suspect clogging and clean the upstream filter. Avoid running dry.
Document the pulse constant of 10,000 per litre in the controller and note the date. If a later reading disagrees with a reference by more than your tolerance, the first suspects are partial blockage of the filter, air in the line or worn gears, in that order.
Ordering and FAQ summary for VCA 0.1 K5F4R1SH
Ask for VCA 0.1 K5F4R1SH by its complete code. Related options: VCA 0.04 K4F4R1SH, VCA 0.2 U5F4R2SH, VCA 2 M4F4P1SH and VCA 5 K5F4R1SH.
Documents and quotation
The datasheet is attached. For availability send an RFQ naming VCA 0.1 K5F4R1SH and the quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht Vca Gear Range
Seven Star LLC supplies models from the Kracht Vca Gear range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10
Answers from our engineering team on installation, compatibility and integration.
01What is the range of KRACHT VCA 0.1 K5F4R1SH?
It measures 0.08 to 10 l/min, with the unit starting at 0.008 l/min at 20 mm2/s.
02How many pulses per litre does VCA 0.1 K5F4R1SH give?
The tooth volume of 0.100 cm3 corresponds to 10,000.00 pulses per litre.
03What is different between VCA 0.1 K5F4R1SH and the VCA 0.04?
The VCA 0.1 offers a higher range (10 instead of 4 l/min) and a lower pulse density, while both are rated 240 bar and use ball bearings.
04What housing material does VCA 0.1 K5F4R1SH use?
The 5 in the code means an aluminium housing with steel gears; the 4 means a hard-coated surface.
05Is VCA 0.1 K5F4R1SH suitable for direction detection?
No, it has one sensor; dual-channel output is offered only on VCA 0.2 and VCG 2.