Brand: KRACHT
KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter
Description
Overview: KRACHT VCA 0.04 K4F4R1SH for very small flows
KRACHT VCA 0.04 K4F4R1SH is the smallest gear type flow meter in the VCA series, built for situations where a few millilitres per second have to be counted precisely. Two high-precision gears with a tooth chamber volume of only 0.040 cm3 are driven by the liquid; the lid-mounted sensor counts each tooth passing and a pre-amplifier in the plug turns the count into a square wave of 25,000 pulses per litre.
The measuring principle is displacement, so the reading does not depend on a straight inlet run and the meter creates no pressure or volume flow pulsation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below follow the KRACHT VCA/VCG datasheet of January 2026.
Order code VCA 0.04 K4F4R1SH decoded
| Parameter | Value |
|---|---|
| VCA | Gear type flow meter, aluminium housing series |
| 0.04 | Nominal size, geometric tooth volume 0.040 cm3 |
| K | Ball bearing |
| 4 | Housing aluminium, gears stainless steel |
| F | FKM sealing |
| 4 | Hard-coated surface |
| R | Pipe connection |
| 1 | One sensor, single channel |
| S | Standard electronics with pre-amplifier |
| H | Hirschmann appliance socket |
Specifications of VCA 0.04 K4F4R1SH
| Parameter | Value |
|---|---|
| Type code | VCA 0.04 K4F4R1SH |
| Measuring range | 0.02 to 4 l/min |
| Measuring unit starting at | 0.004 l/min at 20 mm2/s |
| Resolution | 25,000.00 pulses per litre |
| Maximum pressure | 240 bar |
| Weight | 0.5 kg |
| Typical accuracy | plus/minus 1.0 percent from 20 mm2/s |
| Maximum permissible pressure loss | 16 bar |
| Viscosity | up to 4,000 mm2/s |
| Media temperature | -10 to 80 C |
| Ambient temperature | -10 to 80 C |
| Sound pressure level | up to 60 dB(A) |
| Supply voltage | 12 to 30 V DC, reverse polarity protected |
| Signal | PNP / NPN square wave, 0.3 W per channel |
| Protection | IP 65 |
How VCA 0.04 K4F4R1SH differs from other VCA sizes
Size 0.04 is the finest resolution of the series: 25,000 pulses per litre compared with 10,000 for the VCA 0.1, 5,000 for the VCA 0.2, 500 for the VCA 2 and 191.5 for the VCA 5. It also starts measuring at the lowest flow, 0.004 l/min, but its range is capped at 4 l/min, against 10 l/min for VCA 0.1.
Its type key allows only one construction, ball bearings with an aluminium housing and stainless steel gears. It shares the 240 bar rating with the VCA 0.1 while the larger sizes drop to 200 bar (VCA 0.2 and 2) or 100 bar (VCA 5). At 0.5 kg it is also the lightest.
Applications for VCA 0.04 K4F4R1SH
Typical duties are dosing of small quantities of additive into lube oil, flow checks on bearing lubrication lines, metering of reagents at test benches and measuring consumption of small diesel or hydraulic circuits. For Gulf customers this means analyzer sample loops, compressor lube oil monitoring and R&D stands where the volume is tiny but accuracy still matters.
Because the gears are lubricated by the measured medium, the meter is meant for liquids that lubricate, such as oils and fuels with viscosity from low up to 4,000 mm2/s.
In oil and gas installations the same small flow often has to be verified against a controller set point, for instance the drip rate of an oil mist unit or the make-up flow to a seal system. A pulse meter with 25,000 pulses per litre lets even a slow trickle produce a usable pulse frequency, so the PLC does not have to wait minutes between pulses to compute a rate. The hard-coated surface (code 4) adds protection to the aluminium housing in workshop and outdoor skid environments.
Selection guide and compatibility
Accuracy of plus/minus 1.0 percent is quoted from 20 mm2/s, so very thin liquids will read less accurately and should be confirmed with the factory. Filter the medium: small tooth chambers and bearing clearances are sensitive to particles. The meter can be mounted in any position and accepts flow in either direction.
If your PLC needs direction detection you should look at a two-sensor version of a different size, because the datasheet describes dual-channel output only for VCA 0.2 and VCG 2. Explosion-proof versions (ATEX/IECEx) exist in the series; ask before ordering if the zone requires it.
Mounting and wiring VCA 0.04 K4F4R1SH
Connect the pipe thread, fill slowly and avoid air. Wire the Hirschmann socket: pin 1 UB (brown), pin 2 channel 1 (green), pin 3 not assigned, pin 4 0 V (white). Pulse amplitude is at least 0.8 times the supply voltage and the duty factor is 1:1 plus/minus 15 percent, with power requirement up to 0.9 W.
With a counter that evaluates the rising edge only, the standard resolution applies. The 4-fold evaluation described in the datasheet needs two channels.
Maintenance
Flush the system before starting and use a filter of suitable fineness. If readings drift or start-up flow rises, the bearings or gears may be worn or contaminated; compare with a reference and consult the supplier.
Because the measuring unit is lubricated by the process liquid, never run it dry for long periods and avoid a dry start against full pressure. The sound pressure level of up to 60 dB(A) is low, so a rising noise level is a useful early sign of a problem. Keep ambient and media temperatures within -10 to 80 C, since the FKM seals and electronics are specified only for that window.
Ordering notes and FAQ summary
Order by full code and quantity. Related KRACHT VCA/VCG meters include VCA 0.1 K5F4R1SH, VCA 0.2 U5F4R2SH, VCA 2 M4F4P1SH, VCA 5 K5F4R1SH and VCG 2 M1F1P2SH.
Documents and quotation
The VCA/VCG datasheet is attached. Send an RFQ for VCA 0.04 K4F4R1SH with part number and quantity to Seven Star LLC.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a KRACHT VCA 0.04 K4F4R1SH usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed turbine & positive displacement flowmeters, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Datasheets & Documents
- Datasheet KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What flow range does KRACHT VCA 0.04 K4F4R1SH cover?
The datasheet lists 0.02 to 4 l/min, with the measuring unit starting at 0.004 l/min at 20 mm2/s.
02What is the resolution of VCA 0.04 K4F4R1SH?
The geometric tooth volume of 0.040 cm3 gives 25,000.00 pulses per litre before any 4-fold evaluation.
03What pressure is VCA 0.04 K4F4R1SH rated for?
Maximum pressure is 240 bar, with a maximum permissible pressure loss of 16 bar and a weight of 0.5 kg.
04What materials does VCA 0.04 K4F4R1SH use?
The code 4 stands for aluminium housing and stainless steel gears, K for ball bearing and F for FKM seals.
05What electrical supply does VCA 0.04 K4F4R1SH need?
12 to 30 V DC with reverse polarity protection, PNP or NPN square-wave output of 0.3 W per channel and IP 65 protection.