Brand: Beamex
Beamex 8006160 ePG Mesh Filters for Output (5 pcs)
Description
Beamex 8006160: mesh filters for the ePG output port
Beamex 8006160 is a set of five mesh filters for the output connection of the Beamex ePG electric pressure pump. The filter sits in the output port under the output fitting and keeps impurities from getting into the pump unit, particularly while the pump vents. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
The product picture shows small brass bodies with sintered mesh faces next to threaded brass rings, which is exactly what a technician finds under the fitting when the port is opened.
Key facts
| Item | Detail |
|---|---|
| Part number | 8006160 |
| Description | ePG mesh filters for output connection |
| Pack quantity | 5 pieces |
| Mesh size | Stated as 36 micron in the ePG manual and 37 micron in the maker’s shop listing |
| Location | Under the output fitting of the ePG |
| Tool for removal | 16 mm / 5/8 inch wrench, then flat-head screwdriver for the filter |
| Inspection interval | At least every 3 months |
| Output port | G1/8 inch female (ISO 228/1) with Bx G1/8 male fitting for 40 bar hoses |
| Recommended media | Clean, dry, non-corrosive gases |
| ePG range | Minus 0.85 to 20 bar |
| Wetted parts of pump | Aluminum, brass, stainless steel, NBR, FKM, PEEK, PA, MS, TPE, food grade lubricants |
Replacing or cleaning the filter
The ePG manual covers this in its maintenance chapter. Check the filter at least every three months. Remove the output fitting with a 16 mm or 5/8 inch wrench, then separate the filter with a flat-head screwdriver. If you see any rust on the filter, replace it immediately; otherwise it can be cleaned by blowing compressed air through it.
Because 8006160 comes as five, a technician can keep a stock of spare elements for several service intervals or for several pumps in the same laboratory.
How 8006160 differs from other ePG spares
Among ePG spares this is the lowest-cost consumable and the only one that touches the air path at the output. The piston seal service kit 8006130 and the non-return valve kit 8006145 deal with internal components, the battery pack 8006030 provides power, and the hard case 8003355 or shoulder strap 8006110 are carrying items. A neglected filter is also the earliest warning of trouble: a rusty one hints that moist or corrosive gas has been drawn in, and may precede the condensation problems the manual describes.
In short, order 8006160 for routine upkeep or after rust is found; order the other kits only when the pump itself shows leakage, noise or loss of pressure.
Why the filter matters in the pump’s air path
An electric pressure pump compresses air in a small volume, and any particle or rust flake that enters the pump unit can reach valves and seals. The manual lists clean, dry, non-corrosive gases as the pressure medium and notes that condensation may form inside the pump when pressure is generated. Checking the amount of condensation at least every three months, or more often if performance drops, goes together with checking this filter.
Two methods of condensation removal exist. Method A applies to devices with serial number 20240054 and higher and is preferred; Method B is valid for devices with firmware version 2.20 or later.
Method B, available through firmware 2.20 or later, activates a dry-out mode: hold the coarse adjustment up button while pressing the power button, leave the pressure port open without hoses, and the pump runs for about two minutes before stopping automatically. The manual then has the technician hold the device in several positions for about 15 seconds each so condensation can leave through the bottom holes, changing positions slowly. Method A is more involved, since it requires removing the back cover and plugs from the body bar.
The manual warns that when the ePG is powered on and generating pressure, fingers must be kept out of the piston assembly because the motor is powerful. Keep this in mind whenever the cover is off, and fit the filter set 8006160 only with the pump switched off and the battery removed.
Use in the Gulf region
In humid coastal sites such as Muscat, Sohar and Salalah, moisture and salt in the air are a realistic risk to an internal air path. Pipelines, utilities and refinery instrument teams that calibrate with an ePG therefore benefit from a short routine: inspect the filter, drain condensation, and replace the element at the first sign of rust.
Instrument teams that follow a quarterly service schedule can combine the filter check with the condensation check and the battery inspection. A pack of five 8006160 covers a year or more of regular filter changes for one pump even if a rusty element is found once or twice.
Fitting checklist
- Depressurize and switch off the pump.
- Remove the output fitting with a 16 mm / 5/8 inch wrench.
- Disconnect the old filter with a flat-head screwdriver and inspect the seat for dirt or rust.
- Seat a new element from the 8006160 set of 5 pcs and refit the fitting.
- Run a short pressure test with the hose connected.
Use hand-tightened hose connections only to the maker’s 40 bar hoses and never exceed the pressure of the connected devices.
Related items
Other order codes in the same ePG family are the hard case 8003360 for ePG, 8003355 for ePG and MC6, the shoulder strap 8006110, USB Type-C dust covers 8006120 and the USB Type-A to Type-C cable 6690980.
Documents and quotation
The ePG user manual is the datasheet for Beamex 8006160. To obtain a quotation, send an RFQ to Seven Star LLC with part number 8006160 and the number of five-piece sets required.
What to Include in Your Beamex 8006160 Enquiry
An accurate quotation for the Beamex 8006160 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing process, pressure & temperature calibrators and reply with availability and a realistic delivery estimate.
Other Models in the Epg Spares Range
Seven Star LLC supplies models from the Epg Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 8006030 ePG Li-ion Battery Pack 14.4 V | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8006160 ePG Mesh Filters for Output (5 pcs) | Process, Pressure & Temperature Calibrators | You are viewing this model |
Datasheets & Documents
- Datasheet Beamex 8006160 ePG Mesh Filters for Output (5 pcs) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8006160 ePG Mesh Filters for Output (5 pcs)
Answers from our engineering team on installation, compatibility and integration.
01How many filters are in Beamex 8006160?
The set contains five mesh filters for the output connection of the ePG.
02How often should the ePG filter be checked?
At least every three months, according to the maintenance chapter of the ePG manual.
03Can a dirty filter be cleaned?
Yes, unless it shows rust: rusty filters must be replaced immediately, while others can be cleaned with compressed air.
04What tool is needed to reach the filter?
A 16 mm / 5/8 inch wrench to remove the output fitting, then a flat-head screwdriver to disconnect the filter.
05What gas should the ePG use?
Clean, dry, non-corrosive gases; the filter helps keep impurities out during venting.


















Reviews
There are no reviews yet.