Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] Transmitter

Description

Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]: analog simplicity with PC programmability

Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] is a two-wire transmitter that programs from a Windows application in about a minute, yet outputs a plain 4-20 mA signal without a digital protocol layered on it. It accepts 22 RTD types, 9 thermocouple types and resistance, potentiometer and millivolt sources. The BH2NG enclosure adds an aluminum explosion-proof body and a glass cover so the integral display is visible.

The -IS suffix makes this the intrinsically safe version, with cFMus, ATEX and IECEx approval, and limits the supply to 10-30 V DC. It is the code for sites where simple analog loops are still the plant standard but hazardous-area approval and a local display are required.

The TDY is often chosen as a plant standard because one code covers almost every temperature sensor in the plant. Instead of stocking fixed-range transmitters as spares, the maintenance store holds a few programmable units and sets the input type and range at the time of replacement, which cuts inventory and avoids ordering errors.

Features of TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]

  • High accuracy, up to plus or minus 0.05 C for critical applications, with a 0.03% of span output stage.
  • A large display that can show input, output or toggle between them, with automatic decimal point to two places.
  • Total sensor diagnostics selectable in the configuration software, driving the output upscale to 23.6 mA or downscale to 3.6 mA.
  • Output current limiting at 3.8 mA and 21.4 mA for input over and under range, with a 25 mA hardware limit.
  • Eight or more measurement updates per second, faster than many microprocessor transmitters.

It has no HART channel, so configuration is done with the supplied software and a cable rather than from the loop wires.

TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] specification summary

Datasheet values for the TDY are listed here.

Parameter Value for TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]
Model code TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]
Unit TDY PC-programmable temperature transmitter with display
Input PRG: 22 RTD types (2-, 3-, 4-wire; Pt, Cu, Ni; 10 to 1000 ohm), 9 thermocouple types, -50 to 1000 mV, 0 to 4000 ohm, potentiometer
Output 4-20 mA, linear and scalable
Supply 10-42 V DC; 10-30 V DC with the -IS option
Option -IS: cFMus, ATEX and IECEx intrinsically safe approval
Housing BH2NG: aluminum 2-hub explosion-proof enclosure with glass cover, 1/2-inch NPT
Output accuracy 4.8 microamps (0.03% of the 4-20 mA span)
Response 256 ms typical, 300 ms maximum for 10% to 90% output change
Isolation 500 Vrms input to output to case
Display LCD, top row 10.16 mm, bottom row 5.72 mm, two rows of five characters
Load capability 583 ohms at 24 V typical
Weight BH housing 1.5 kg; HP 178 g; D2LC 688 g
Stability T/C, mV (1/3/5 years) 0.11%, 0.18%, 0.24% of conformance range
Ambient -40 to +85 C; 0 to 95% RH
Measurement cycle At least 8 updates per second

How TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] differs from THZ and TRY units

The THZ and TDZ families are smart HART devices; the TDY is analog with PC configuration only. It supports 22 RTD types against 14 on the THZ3, and its response of 256 ms typical is quicker than the first-generation THZ. Compared with the TRY, which has no display and is available in puck, DIN or LH housing, the TDY always carries the display.

BH2NG with -IS is also distinct from the D2LC option: D2LC is a light 688 g IP66 box, whereas the BH weighs 1.5 kg because it is an explosion-proof casting.

Think of the table as the profile of a classic analog transmitter: 0.03% output accuracy, stability expressed over one, three and five years, and a measured response of 256 ms typical. Notice the load capability of 583 ohms at 24 V, which is generous enough for most DCS input cards with surge protection.

Where TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] is applied

Typical sites are older plants with analog DCS cards that now need hazardous-area approved smart-input transmitters, such as refinery process lines, storage tanks and utility headers. The local readout supports operator rounds in areas where handhelds are restricted.

In the GCC, the BH2NG body fits outdoor mounting on a pipe or surface.

Choosing TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]

Verify the hazardous-area scheme: cFMus, ATEX and IECEx apply with the -IS option; the A or E suffixes on the BH housing relate to flameproof (Ex d) approvals and may be requested separately. Ensure the loop supply is within 10-30 V DC for the I.S. version.

The 10 V minimum means the load limit equals the supply minus 10 V divided by 0.024 A.

Installation

Fix the BH to a pipe with the proper hardware, fit certified glands and connect the sensors. Connect a PC through the supported configuration cable, select input type, range, display options and burnout direction, and download the configuration to the transmitter.

Check that the display shows the expected temperature and that the loop current tracks it.

When commissioning an I.S. loop, remember that the entity parameters of the cable and the barrier must be calculated for the whole circuit. The transmitter approval is only one element of the loop documentation, which also includes the supply, the cable length and the sensor.

Maintenance

Check the glass and seals during inspections. Compare against a reference source if the application requires it; the stability table allows several years between calibrations for typical spans.

The configuration file can be re-downloaded to a replacement unit.

Supply of TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]

Quote TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] in full in any enquiry and state the sensor and range.

Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.

Documents and quotation

The datasheet for Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] can accompany our quotation. Submit an RFQ with the part number, quantity and delivery location.

Datasheets & Documents
  • PDF Datasheet Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG] Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries TDY/PRG/4-20MA/10-42DC/-IS [BH2NG]

Answers from our engineering team on installation, compatibility and integration.

01Does the TDY use HART?
No. It is a PC-programmable analog transmitter with a 4-20 mA output; configuration is through supplied software.
02What does -IS provide?
cFMus, ATEX and IECEx intrinsically safe approval, with the supply limited to 10-30 V DC.
03How many RTD types does it accept?
Twenty-two RTD types, plus nine thermocouple types, millivolt, resistance and potentiometer inputs.
04How fast is the output response?
256 ms typical and 300 ms maximum for a 10% to 90% change.
05How heavy is the BH housing version?
The datasheet gives 1.5 kg for the BH housing.