Brand: MTL (Eaton)
MTL MTL7788R+ 1-5 V Systems Safety Barrier
Description
What the MTL7788R+ is for
In many control systems the field loop is converted to a voltage at the marshalling cabinet. A 250 ohm resistor turns 4-20 mA into 1-5 V, and the MTL MTL7788R+ is the barrier the manufacturer assigns to that arrangement. It carries two channels: a 28 V, 300 ohm, 93 mA channel for the feed to the transmitter and a 10 V, 50 ohm, 200 mA channel for the return, with bussed 24 V power from the 7700 power bus.
MTL7788R+ data at a glance
| Part number | MTL7788R+ |
|---|---|
| Channel 1 | 28 V, 300 ohm, 93 mA, 333 ohm end to end |
| Channel 2 | 10 V, 50 ohm, 200 mA, 75 ohm end to end |
| Working voltages | 25.9 V and 6.0 V |
| Maximum voltages | 26.5 V and 7.0 V |
| Fuse ratings | 50 mA and 50 mA |
| Polarity | positive |
| Bussed power | yes |
| Typical application | 1-5 V systems |
| MTL700 equivalent | MTL788R+ |
| Ambient temperature | -20 to +60 degrees C |
| Storage | -40 to +80 degrees C |
| Humidity | 5 to 95 percent RH |
| Terminals | removable, up to 2.5 mm2 (13 AWG) |
| Weight | about 140 g |
Differences from other MTL7788 and MTL7787 versions
Look at the second channel first. The MTL7787+ pairs 28 V, 300 ohm, 93 mA with a diode return, and the MTL7787P+ uses 28 V, 234 ohm, 119 mA with a diode. The MTL7788+ and MTL7788R+ both put a second resistive 10 V, 50 ohm, 200 mA channel in place of the diode. That resistive second channel is what the datasheet circuit uses on the return side of the transmitter loop.
Between the two 7788 types the channel ratings in the table are identical; the datasheet separates them by application, the MTL7788+ for transmitters and the MTL7788R+ for 1-5 V systems. Order the one that matches the way the receiving system reads the signal.
Wiring picture for the MTL7788R+
The manufacturer drawing shows 24 V supplied from the power bus on one side, the transmitter on terminals 3 and 4 in the hazardous area and a 250 ohm resistor producing a 1-5 V reading, with the pair of safe-area terminals carrying power and signal. Because power is drawn from the bus, there is no separate power wiring to each barrier, and a row of modules can be fed from one MTL7798 or MTL7799.
This saves time on large racks of loops and makes later checks simple.
Where the MTL7788R+ is used in Oman and the GCC
- Older distributed control systems with 1-5 V analog input cards
- Gas compression and metering stations with DCS cabinets based on voltage inputs
- Power station auxiliary systems with legacy instrument loops
- Refinery tank-farm monitoring panels
- Replacement of a failed channel when the original drawing lists the MTL788R+ equivalent
Installation and commissioning notes
Install on DIN rail and connect hazardous-area wiring to the blue-labelled terminals. Provide a 24 V source that is within the barrier working voltage and, for a bus-fed row, a protection module upstream. Measure the 250 ohm resistor value before connecting, as small errors become visible directly in the 1-5 V scale.
After wiring, simulate a 4 mA and a 20 mA loop current and check that the receiving card reads 1 V and 5 V.
Maintenance and replacement
If a replacement is needed, match the part number exactly rather than substituting an MTL7788+, because the loop design assumes the resistive return. Record the tag on the TH7700 identifier. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Planning a rack with MTL7788R+ and the power bus
A rack of bus-fed barriers is wired once and extended easily. The manufacturer states that the PB7700 power bus can serve up to 40 barriers, supplied through an MTL7798 power feed module or an MTL7799 dummy barrier. Looping the feed to both ends of the bus gives redundancy in wiring, so one barrier can be removed without losing power to the rest.
For a 1-5 V system, the typical design uses the MTL7788R+ for each transmitter and a 250 ohm resistor for each channel. Check that the resistor tolerance suits the accuracy target, because a 1 percent resistor contributes about 1 percent error in the voltage reading. The ordering list also names ETL7000 earth terminals, ISP7000 insulating spacers and TAG57 tagging strips, all of which are useful in a tidy rack.
Finally, record the part number in the instrument index so that future maintenance staff know that these positions need the R+ version and not a plain transmitter barrier.
Log loop number, transmitter tag, barrier position, resistor value and the 1 V and 5 V check readings. This simple record is invaluable when a barrier is later replaced and the new module needs to be proven against known-good figures.
Document the polarity as well. The MTL7788R+ is a positive barrier, so its label is red, and the datasheet reminds installers that the colour code distinguishes positive, negative and non-polarised barriers at a glance. A wrong-polarity swap on a rack is easy to spot visually, which is a quiet benefit during commissioning walk-downs in a hot, poorly lit marshalling room.
Commissioning teams should also confirm the channel ratings against the field transmitter certificate. The 28 V, 300 ohm, 93 mA channel feeds the transmitter, so the transmitter must accept those entity values, and its cable capacitance and inductance must stay inside the allowances written in the barrier certificate. For the lower 10 V, 50 ohm, 200 mA channel, the same comparison applies to anything connected to it. Mixing up the two channels is the most common wiring error on dual-channel barriers, and a continuity test before powering removes the risk.
Documents and quotation
The range datasheet and manual are available for download. For a quotation, send your RFQ with MTL7788R+, quantity and delivery details.
Other Models in the MTL7700 Shunt Diode Range
Seven Star LLC supplies models from the MTL7700 Shunt Diode range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| MTL MTL7707P+ IIB Two-Channel Safety Barrier | Isolator & Barrier | View details |
| MTL MTL7788R+ 1-5 V Systems Safety Barrier | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet MTL MTL7788R+ 1-5 V Systems Safety Barrier Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.
Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.
MTL (Eaton) company profile
| Founded | 1971, Luton, England, as Measurement Technology Ltd |
|---|---|
| Origin | Spin-off from Kent Instrumentation |
| Headquarters | Luton, England |
| Ownership | Eaton (Crouse-Hinds), via Cooper Industries from 2008 |
| Product families | MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points |
Milestones
- 1971: Measurement Technology Ltd is founded in Luton.
- 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
- 2008: Cooper Industries acquires MTL Instruments for £144 million.
- 2012: Eaton acquires Cooper Industries.
MTL product families listed here
Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.
Where MTL barriers and isolators are used
These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.
MTL (Eaton) products we list
Ordering MTL modules: what we need
Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.
Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.
Browse MTL (Eaton) products by category: Isolator & Barrier, Automation Software.
FAQ
Questions about the MTL MTL7788R+ 1-5 V Systems Safety Barrier
Answers from our engineering team on installation, compatibility and integration.
01What is the MTL7788R+ intended for?
The correlation table lists it for 1-5 V systems. It powers a 4-20 mA transmitter through a 250 ohm resistor so the DCS sees a 1 to 5 V signal.
02What are the two channel ratings?
Channel one is 28 V, 300 ohm, 93 mA with 333 ohm end to end; channel two is 10 V, 50 ohm, 200 mA with 75 ohm end to end. Fuses are 50 mA on both.
03Does the MTL7788R+ support the bussed power feed?
Yes. The correlation table marks bussed power as Yes and the power bus application list names the MTL7788R+ among the compatible modules.
04Which MTL700 part does it correspond to?
The MTL700 range equivalent is the MTL788R+. There is no MTL7000 range equivalent listed.
05How does it differ from the MTL7788+?
The channel data in the datasheet table is the same, 28 V 300 ohm 93 mA plus 10 V 50 ohm 200 mA. The datasheet separates them by application: MTL7788+ for transmitters, MTL7788R+ for 1-5 V systems.


















Reviews
There are no reviews yet.