Brand:

Beamex 9893000 MC6-WS Advanced Workshop Calibrator

Description

Beamex 9893000 MC6-WS panel-mounted workshop calibrator

Beamex 9893000 is the MC6-WS, the advanced workshop calibrator and communicator built into the front panel of a Beamex CENTRiCAL calibration bench, trolley or tabletop. It is the same family of technology as the portable MC6, but instead of a handheld case with a stand, the 9893000 is mounted in an instrument panel and wired to the other bench modules through a rear connector. Beamex describes it as the heart of the CENTRiCAL workshop calibration solution.

A technician sees a 5.7 inch color touch screen, a column of measurement and generation terminals, two thermocouple ports and two USB sockets, and can calibrate pressure, temperature and electrical signals from one station, or use it as a HART, FOUNDATION Fieldbus and Profibus PA communicator.

Functions of the 9893000 in one list

  • Pressure measurement, with up to 10 pressure modules connected internally inside the CENTRiCAL; one external module at a time through the PX port and an EXT cable.
  • Voltage measurement and generation, current measurement and generation, frequency measurement and generation, pulse counting and generation, and switch state sensing.
  • A built-in 24 V DC loop supply for powering transmitters.
  • Resistance measurement and simulation, with two simultaneous channels.
  • RTD measurement and simulation and thermocouple measurement and simulation, each with two simultaneous channels.
  • Multi-bus communicator for HART, FOUNDATION Fieldbus and Profibus PA instruments, to calibrate, configure and trim smart devices.

9893000 general specifications

Parameter Value
Order code 9893000
Display 5.7 inch diagonal, 640 x 480 TFT LCD, backlit
Touch panel 5-wire resistive touch screen
Operating temperature 0 to 45 degrees C, also during battery charging
Operating humidity 0 to 80 %RH, non condensing
Storage temperature -20 to 60 degrees C
Maximum altitude 3000 m (about 9800 ft)
Maximum input voltage 30 V AC, 60 V DC
Battery Li-ion, 4300 mAh, 11.1 V; about 4 hours charging, 10 to 16 hours of operation
USB Two USB-A on the front, further USB-B and USB-A at the rear
Certificate Accredited calibration certificate delivered as standard

Accuracy figures for each measurement and generation function are published on the product page of the manufacturer and are not repeated here.

Terminals and connectors on the 9893000 panel

The front carries the thermocouple and millivolt ports TC1 (for cables and standard plugs, with release buttons) and TC2 (flat-contact plugs), the RTD and resistor terminals R1, an output terminal group for voltage, current and frequency, and input terminals for voltage, frequency and switch plus a current measurement, loop supply and smart-instrument terminal. A PX connector accepts an external pressure module, an R2 connector lets you attach an external RTD sensor, and the panel has Enter, arrow, Home and Power buttons. At the rear you find isolated and non-isolated USB-B ports, USB-A ports for devices such as a Bluetooth adapter, the connector for the pressure modules in the CENTRiCAL and the power connector used to charge the calibrator.

Documenting and software links

The 9893000 stores instruments, calibration results and data logs in shockproof solid-state memory that does not need power, and everything stays on the calibrator unless you export it. As a documenting calibrator it works with Beamex calibration management software, so that calibration procedures and results can be exchanged with the software instead of being copied by hand. Data transfer is by USB, or wirelessly using the optional Bluetooth adapter and the wireless option.

Selecting 9893000 compared with a portable MC6

The MC6-WS fits a calibration lab; a handheld MC6 such as 9270000 fits the field. In the workshop the 9893000 gains from a fixed position, the shared pressure modules inside the CENTRiCAL bench and the possibility of integrating a POC8 controller, power supplies and multimeters. Its battery only keeps it running when the bench is shut down and retains the clock. Specify the pressure ranges of the internal modules separately: the brochure lists modules from barometric to 600 bar internally, and 1000 bar as an external EXT module.

Installation and commissioning of the 9893000

The CENTRiCAL benches are delivered assembled and calibrated, with the MC6-WS inside the instrument panel. After placing the bench, connect mains power to the bench, switch on the 9893000 with the Power button and review the clock and display settings. Connect the PC for calibration software by USB or Bluetooth, and connect any EXT module with the EXT cable to the PX port. Touch the screen with fingertips only; the manual warns against hard or sharp objects, and gloves are acceptable.

Battery and electrical safety limits of the 9893000

Respect the maximum input voltage of 30 V AC or 60 V DC on the measurement inputs. The lithium-ion pack is classified as hazardous waste at end of life and must never be crushed, short-circuited or burned. For transport or storage keep it at about 30 percent charge, because a full or empty pack can lose capacity; if the 9893000 is unused for long periods, recharge it every three months. Storage temperature for a charged-to-30-percent pack is -20 to 45 degrees C up to one month and -20 to 30 degrees C beyond three months. When the internal clock resets, the manual says the pack should be replaced.

Uses in Oman and the GCC

Central instrument workshops in refineries, petrochemical complexes, power utilities and desalination plants run bench calibrations of transmitters, switches, indicators and recorders. The 9893000 lets one technician cover pressure, temperature, loop signals and fieldbus devices at the same bench with automatic procedures.

Documents and quotation

The CENTRiCAL brochure describes the MC6-WS function list and pressure module ranges, while the MC6-WS user manual covers the specification tables used here. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Beamex 9893000, the quantity and the bench or module configuration you need.

Datasheets & Documents
  • PDF Datasheet Beamex 9893000 MC6-WS Advanced Workshop Calibrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9893000 MC6-WS Advanced Workshop Calibrator

Answers from our engineering team on installation, compatibility and integration.

01What is Beamex 9893000?
It is the MC6-WS panel-mounted workshop calibrator and communicator, used as the heart of a CENTRiCAL calibration bench, trolley or tabletop.
02Which fieldbus protocols does the 9893000 support?
It contains a multi-bus communicator for HART, FOUNDATION Fieldbus and Profibus PA instruments.
03How many pressure modules can the MC6-WS hold?
Up to 10 pressure modules can be connected internally, and one external EXT module can be connected through the PX port.
04What is the battery for in the 9893000?
The Li-ion battery lets it run when the bench is shut down and keeps the internal clock and calendar.
05Does the 9893000 ship with a calibration certificate?
Yes, each MC6-WS is delivered with a traceable accredited calibration certificate as standard.