Brand: KRACHT
KRACHT VC 3 G1E1P2SH Gear Flow Meter
Description
KRACHT VC 3 G1E1P2SH overview
KRACHT VC 3 G1E1P2SH is a KRACHT VC gear type flow meter of nominal size 3: two meshing gears turn as oil passes through, each tooth chamber holds 3.000 cm3, and magnetic sensors count the passing teeth to produce a pulse train that is proportional to volume.
Typical accuracy is plus or minus 0.3 percent of the measured quantity with repeatability of plus or minus 0.05 percent under stable conditions, backed by test results traceable to the German accreditation body DAkkS.
Code G1 marks a carbide plain bearing in a cast iron housing, a combination meant for media that lubricate poorly or are very viscous, for instance offset ink, polyol, isocyanate, glue, resin and silicone.
Size 3 doubles the tooth volume of a size 1 meter to 3.000 cm3, which returns 333.33 pulse/l and a starting point of 0.03 l/min.
Key features of VC 3 G1E1P2SH
- Electronics: 2 sensors with standard pre-amplifier S and Hirschmann appliance socket H; 10 to 30 V supply, IP 65
- Tooth volume 3.000 cm3 offers 333.33 pulse/l per channel before the optional four-fold evaluation
- Sound level up to 70 dB(A) and weight 9.0 kg (spheroidal cast iron, integrated electronics)
- Pulsation-free measurement, any mounting position and any flow direction
- Pressure rating 350 bar and viscosity capability to 2 500 000 mm2/s
- Measuring range 0.6 to 100 l/min and starting point 0.03 l/min
VC 3 G1E1P2SH technical specifications
| Parameter | VC 3 G1E1P2SH |
|---|---|
| Sensors / electronics | 2 sensors with standard pre-amplifier S and Hirschmann appliance socket H; 10 to 30 V supply, IP 65 |
| Pressure limit | 350 bar |
| Bearings | carbide plain bearing (code G), specification G1 |
| Connection | plate mounting (P) onto a connection plate |
| Measuring range | 0.6 to 100 l/min |
| Geometric tooth volume | 3.000 cm3 |
| Sound pressure level | up to 70 dB(A) |
| Starting point | 0.03 l/min |
| Mass | 9.0 kg (spheroidal cast iron, integrated electronics) |
| Order code | VC 3 G1E1P2SH |
| Permissible particle size | 30 micrometres |
| Maximum permissible pressure loss | 16 bar |
| Viscosity | up to 2 500 000 mm2/s |
| Housing / gears | housing spheroidal cast iron GJS-400-15, gears steel 1.7131 |
Reading the type key of VC 3 G1E1P2SH
| Position | Code and meaning |
|---|---|
| VC | gear type flow meter |
| 3 | nominal size 3 (tooth volume 3.000 cm3) |
| G | carbide plain bearing |
| 1 | housing spheroidal cast iron GJS-400, steel gears |
| E | EPDM sealing |
| 1 | coated surface |
| P | plate mounting |
| 2 | 2 sensors |
| S | standard pre-amplifier |
| H | Hirschmann appliance socket |
The pair G1 selects the carbide plain bearing with a cast iron housing; for stainless steel media paths the data sheet offers G2.
Sealing E is EPDM; the sealing material must always be checked against the pumped fluid before ordering.
How VC 3 G1E1P2SH differs from alternative VC variants
VC nominal sizes run 0.025, 0.04, 0.1, 0.2, 0.4, 1, 3, 5, 12, 16. VC 3 G1E1P2SH is size 3 with 3.000 cm3 tooth volume and a resolution of 333.33 pulse/l.
Against the next smaller size 1 (1.036 cm3, 965.25 pulse/l) this device has 1.964 cm3 more per tooth chamber, and its starting point goes up from 0.02 to 0.03 l/min.
Against the next larger size 5 (5.222 cm3, 191.50 pulse/l) it provides finer resolution: 333.33 against 191.50 pulse/l, and starts to count at 0.03 rather than 0.04 l/min.
Measured against the K1 ball-bearing meter of the same size, this G1 variant measures 0.6 to 100 l/min rather than 0.6 to 160 l/min, accepts particles up to 30 micrometres in place of 20, and tops out at 80 degrees C rather than 210 degrees C as carbide plain bearings and EPDM seals set the limit.
Typical applications of VC 3 G1E1P2SH in Oman and the GCC
Test benches for pumps, valves and filters use VC meters since the resolution of 333 pulse/l is enough for short test cycles; the data sheet names test bench construction as a common use.
Printing machines use the G1 specification for consumption measuring of offset ink, according to the data sheet application chart.
Oil filling and metering stations use the pulse output to batch a set volume; at 3 cm3 per tooth chamber each tooth-pass is a tiny portion of the batch.
Dosing and ratio control for resins, polyols, isocyanate and adhesives in manufacturing depends on constant counting at low flow; the data sheet names these media for the carbide and stainless-steel versions.
Selection and compatibility notes for VC 3 G1E1P2SH
Pressure: this specification is designed for 350 bar; check the system peak pressure against that figure.
Filter the liquid: the permissible particle size for this specification is 30 micrometres, and a protective filter ahead of the meter is advised.
Viscosity: the catalogue allows up to 2 500 000 mm2/s; very viscous media need a low flow so that pressure loss stays below 16 bar.
Pipework: plate mounting (P) onto a connection plate
Installation, commissioning and maintenance of VC 3 G1E1P2SH
Install VC 3 G1E1P2SH in any position and flow direction; the device requires no inlet or outlet straight run, so it suits small-footprint skids.
Commission by running at a known flow and comparing the counted volume with a reference; a calibration with a measurement accuracy characteristic may be requested from the manufacturer.
Fasten the device to its connection plate or pipe thread with the specified torque and keep the sensor electronics away from heat sources above their rated ambient limit.
Keep a record of the ordering code VC 3 G1E1P2SH so that spare or replacement meters match the bearing, material, seal and electronics letters exactly.
The device has no wearing seals further than the EPDM elements, so maintenance is limited to keeping the liquid clean and checking the sensor connector.
VC 3 G1E1P2SH FAQ summary
What is VC 3 G1E1P2SH used for? The G1 specification suits medium to high viscosity, poorly lubricating media for instance ink, glue, resin and isocyanate, as an illustration consumption measuring in printing machines.
What is the measuring range of KRACHT VC 3 G1E1P2SH? 0.6 to 100 l/min with a starting point of 0.03 l/min.
How high is the medium temperature for VC 3 G1E1P2SH? The range is -40 to 80 degrees C, limited by the carbide plain bearing specification.
Documents and quotation
Use the attached KRACHT VC gear type flow meter data sheet PDF, which contains the type key, technical data, electronics, drawings and weights, when you check VC 3 G1E1P2SH against your drawing.
Your RFQ should state the complete part number VC 3 G1E1P2SH, how many pieces you need and where in Oman or the GCC they should go. Nameplate data speeds up the check.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet KRACHT VC 3 G1E1P2SH Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VC 3 G1E1P2SH Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is VC 3 G1E1P2SH used for?
The G1 specification suits medium to high viscosity, poorly lubricating fluids such as ink, glue, resin and isocyanate, for example consumption measuring in printing machines.
02What is the measuring range of KRACHT VC 3 G1E1P2SH?
0.6 to 100 l/min with a starting point of 0.03 l/min.
03How high is the medium temperature for VC 3 G1E1P2SH?
The range is -40 to 80 degrees C, limited by the carbide plain bearing specification.
04What is the pressure rating of VC 3 G1E1P2SH?
350 bar for size 3 with carbide plain bearings.
05Which particle size can VC 3 G1E1P2SH tolerate?
Up to 30 micrometres in the pumped medium.