Magnetrol 089-7250-002 8A DPDT AC Electronics Module for Thermatel TD2

Description

Magnetrol 089-7250-002 overview: electronics module for the Thermatel TD2

The Magnetrol 089-7250-002 is the replacement integral electronics module for the Thermatel TD2 with an 8 amp DPDT relay on AC power. The manual lists it for integral electronics (8th model digit 0) with AC supply (4th digit 7) and the 8 amp DPDT relay, used with TD2-XD0X-X3X and TD2-XD0X-XGX. Maintenance planners search for this exact number because the Thermatel TD2 is built in many variants, and a board or module for the wrong variant can leave a level or flow loop out of service during a shutdown window.

The picture on this page is the manufacturer product image for the Thermatel Model TD2 thermal dispersion flow and level switch, which is the family that uses the 089-7250-002. It is not a close-up of the electronics module itself. Every value below comes from the manufacturer manual 54-610 and catalog pages for that family, and where a value is not published for this specific part we have left it out instead of guessing.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list 089-7250-002 so that buyers can quote the number exactly as printed in the manual, and we confirm availability against your quotation request.

Key features of 089-7250-002

  • Exact manufacturer part number 089-7250-002, shown in the replacement parts section of manual 54-610.
  • Function: electronics module for the Thermatel TD2, selected by the model number digits printed on the transmitter nameplate.
  • Fits the Thermatel Model TD2 thermal dispersion flow and level switch, which the manufacturer describes as follows: The Thermatel TD2 is a thermal dispersion switch. A heated sensor and a reference sensor sense whether the process is flowing, wet or dry from how fast heat is carried away, and the electronics switch a relay at the set point.
  • Replacing a plug-in or board-level part can restore a loop without replacing the whole instrument, which keeps process piping, flanges and the probe or antenna untouched.
  • The manual advises that the nameplate model and serial number should always be quoted when spare parts are ordered.

089-7250-002 technical specifications

Parameter Value
Manufacturer Magnetrol (AMETEK)
Part number 089-7250-002
Part type Electronics module
Used in Thermatel Model TD2 thermal dispersion flow and level switch
Principle Thermal dispersion, flow, level and interface switching
Supply options 100 to 264 VAC or 19.2 to 28.8 VDC
Relay options 8 amp DPDT, or 1 amp hermetically sealed
Electronics ambient temperature -40 to +158 F (-40 to +70 C)
Sensor temperature -100 to +400 F (-73 to +204 C); high temperature sensor -100 to +850 F (-73 to +454 C)
Mounting Integral or remote electronics
Manual 54-610

The family values in the table describe the instrument that the 089-7250-002 belongs to and are quoted from manual 54-610. The 089-7250-002 itself is a replacement part and carries the model-code rules summarized in the selection section below.

Typical applications for the Thermatel TD2 and 089-7250-002 in Oman and the GCC

Instruments of this family are used in pump protection and low-flow alarms on cooling water and lube lines, seal-flush monitoring, tank high and low level alarms, and interface detection in separators. In Oman and across the GCC these duties appear in oil and gas production and processing, petrochemical and fertilizer plants, power and desalination stations, municipal water and wastewater works, and general manufacturing.

Typical reasons to buy a spare such as the 089-7250-002 are a failed board after a lightning surge or moisture ingress, a unit that has reached the end of service life, or a plant that wants a spare on the shelf for critical tags instead of waiting for a long lead time during an outage.

Selection and compatibility notes for 089-7250-002

The manual lists it for integral electronics (8th model digit 0) with AC supply (4th digit 7) and the 8 amp DPDT relay, used with TD2-XD0X-X3X and TD2-XD0X-XGX. Always compare the full model number on the nameplate with the manual before ordering, because boards for different outputs, approvals and housings are not interchangeable.

  • Read the 5th and 6th digits of the model number first. They set the output and safety option and decide which electronics are fitted.
  • Read the classification digit next. Explosion-proof, flameproof, intrinsically safe and non-sparking versions can use different boards.
  • Confirm the display and housing digits if the part is a display, cover or housing-related item.
  • Send the serial number with the RFQ so the part can be checked against the configuration of the instrument.

If you are unsure whether 089-7250-002 is right for your tag, send us the nameplate photo and we will compare it with the parts list before quoting. The manual also names related spares for this family, including 089-7250-002 to 089-7250-013 electronic modules, 003-1230-004 bezel, 030-3586-001 remote circuit board, and the 012-2201-237 O-ring.

Installation and commissioning with 089-7250-002

De-energize the unit, open the housing and replace the module with the one whose AC or DC and integral or remote code matches the model number. The manual calls for a probe with heat extension or remote electronics when process temperature exceeds 250 F (120 C).

Follow the safety instructions of the manufacturer manual 54-610 for the hazardous area classification of the installation. In classified areas do not open housings while the circuit is live unless the area is known to be non-hazardous, and re-fit all covers and O-rings fully before power is restored. After fitting the 089-7250-002, record the date, the tag and the part number in the maintenance log.

Maintenance and spare strategy

Clean the sensor tip when scale or coating builds, re-check the switch point after any module replacement, and test the relay output against the control logic during planned outages.

For critical level and flow measurements many plants keep one electronics module such as the 089-7250-002 per instrument family on site. This shortens repair time because the technician only has to swap the part and reload the configuration instead of waiting for a complete replacement transmitter.

Related products and ordering notes for 089-7250-002

Other spares in the same family that buyers often request together with 089-7250-002 include 089-7250-002 to 089-7250-013 electronic modules, 003-1230-004 bezel, 030-3586-001 remote circuit board, and the 012-2201-237 O-ring. These are listed in the manufacturer manual under replacement parts, and we can quote them in the same RFQ.

For each line please state the part number, the quantity, the tag number and the delivery location in Oman or the GCC. We will confirm availability and lead time and return a written quotation.

FAQ summary

  • What is the Magnetrol 089-7250-002? The 089-7250-002 is the replacement integral electronics module for the Thermatel TD2 with an 8 amp DPDT relay on AC power. It is listed in the replacement parts section of the manufacturer manual 54-610.
  • Which instrument uses the 089-7250-002? It is listed for the Thermatel Model TD2 thermal dispersion flow and level switch. The manual lists it for integral electronics (8th model digit 0) with AC supply (4th digit 7) and the 8 amp DPDT relay, used with TD2-XD0X-X3X and TD2-XD0X-XGX.
  • How do I confirm that 089-7250-002 matches my instrument? Compare the model number digits on the nameplate with the parts list in manual 54-610 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
  • Can Seven Star LLC supply 089-7250-002 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with 089-7250-002, the quantity and the delivery location and we will confirm availability.
  • Is documentation available for 089-7250-002? Yes. The manufacturer manual 54-610 with the replacement parts list is available from this page as a datasheet download, and the nameplate data of your unit should always be checked against it.

Documents and quotation

The manufacturer manual 54-610 for the Thermatel TD2 is attached to this page as the datasheet for 089-7250-002. It contains the replacement parts list, model number tables, wiring diagrams and specifications referred to above. To request a quotation, send the RFQ with the part number 089-7250-002, the quantity, the instrument tag and the nameplate model and serial number. Seven Star LLC will reply with availability and lead time for Oman and the GCC.

Other Models in the Magnetrol Td Range

Seven Star LLC supplies models from the Magnetrol Td range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol 089-7250-001 Electronic Module with Bracket, Thermatel TD1Level SwitchesView details
Magnetrol 089-7250-002 8A DPDT AC Electronics Module for Thermatel TD2Level SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Manual Magnetrol 089-7250-002 8A DPDT AC Electronics Module for Thermatel TD2 Manual with Parts List Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol 089-7250-002 8A DPDT AC Electronics

Answers from our engineering team on installation, compatibility and integration.

01What is the Magnetrol 089-7250-002?
The 089-7250-002 is the replacement integral electronics module for the Thermatel TD2 with an 8 amp DPDT relay on AC power. It is listed in the replacement parts section of the manufacturer manual 54-610.
02Which instrument uses the 089-7250-002?
It is listed for the Thermatel Model TD2 thermal dispersion flow and level switch. The manual lists it for integral electronics (8th model digit 0) with AC supply (4th digit 7) and the 8 amp DPDT relay, used with TD2-XD0X-X3X and TD2-XD0X-XGX.
03How do I confirm that 089-7250-002 matches my instrument?
Compare the model number digits on the nameplate with the parts list in manual 54-610 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
04Can Seven Star LLC supply 089-7250-002 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with 089-7250-002, the quantity and the delivery location and we will confirm availability.
05Is documentation available for 089-7250-002?