Schneider Electric SLAWLXX SpaceLogic SLA Room Sensor
Description
SLAWLXX: SpaceLogic SLA room temperature sensor with segmented LCD with buttons
The SLAWLXX is a Schneider Electric SpaceLogic SLA Series room unit in a glossy white wall housing. It measures temperature and returns analogue outputs, and the datasheet lists a 2 inch LCD with + / – / arrow buttons. Seven Star LLC supplies it as an independent supplier in Oman and the GCC for HVAC contractors, BMS integrators and fit-out teams.
The family names on the datasheets follow a pattern that we read as follows, from titles only and not from an ordering table: the fourth letter points to the housing (B black, W glossy white, S matt white), the fifth to the face (T touchscreen, L segmented LCD, X none) and the last letter to the measurement (2 for humidity plus temperature, X for temperature only). This reference is the resistive 10K T3 version according to its title, so the temperature element is a passive resistive type.
Selection checklist for the SLAWLXX
A room unit is chosen by three questions: what must it measure, who touches it, and which controller reads it. The list below turns those questions into checks that can be copied into a submittal or a purchase request.
- Measurement: temperature.
- Face: segmented LCD with buttons.
- Housing: glossy white.
- Controller: SmartX Room Purpose Controller compatibility and output scaling.
- Supply: 24 V AC or 20–30 V DC.
- Placement: internal wall, away from sun, diffusers and heat sources.
Where several room types share one controller design, keep a schedule of references per room so that the correct housing and face reach the correct wall during installation.
Display and user interface
The face is a 2 inch segmented LCD with plus, minus and arrow buttons. It shows temperature, set point and a menu-driven interface, in a layout that is simple to explain to occupants and maintenance staff.
When you compare references, the housing colour and the face are the visible differences, while the supply, outputs and compatibility listed on the datasheets are essentially the same across the family. Choose the face by who will use the room, not by the part number alone.
Installation and commissioning
Mount the unit on the wall at the height the project drawings specify, make the screw-terminal connections, and power up. Verify the readings against a reference thermometer placed next to the sensor, and record the offset if the project requires one.
Avoid painting or sealing the housing, and keep spares of SLAWLXX for rooms that cannot wait for a replacement. A cover that becomes dirty or damp during fit-out can affect readings, so protect it until the finishing work is complete.
Outputs, supply and wiring of the SLAWLXX
The datasheet lists analogue outputs: one for fan speed at 0–10 V and one configurable output at either 0–5 V or 0–10 V. The supply is 24 V AC at 50–60 Hz or 20–30 V DC. Connections are on screw terminals accepting two cables of 24 to 18 AWG.
Check the output scale configured in the controller against the room unit before commissioning this unit, as a 0–5 V against 0–10 V mismatch will give half-range readings. Keep sensor cabling away from power cables and use twisted pair for longer runs.
Controller compatibility and system fit of the SLAWLXX
The datasheet lists compatibility with EcoStruxure Building Operation SmartX Room Purpose Controller programmable controllers. That is the intended controller family, and the analogue fan and configurable outputs are what those controllers read. Use with other controllers is a design decision outside the datasheet, so confirm it before ordering.
Related references in the same family include SLABTXX, SLASXX2, SLAWLX2, SLAWLXX, SLAWTX2, SLAWTXX and SLAWXX2, which differ by housing, face and humidity element. A project with mixed room types often combines several of them under one controller design.
Technical specifications of the SLAWLXX
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / SLAWLXX |
| Range | SpaceLogic SLA Series (SpaceLogic Room Unit) |
| Product type | Temperature sensor |
| Measurement | Temperature |
| Applications | HVAC; temperature control; fan speed controller |
| Temperature setting range | 10–35 °C; 0–50 °C |
| Temperature measurement range | 0–50 °C |
| Measurement accuracy | Typical ± 0.2 % |
| Display | 2 inch LCD with + / – / arrow buttons |
| Operator control | + / – / arrow buttons |
| Output type | Analog |
| Outputs | 1 fan; 1 configurable |
| Output voltage | 0–10 V fan speed; 0–5 V or 0–10 V configurable |
| Rated supply voltage | 24 V AC 50–60 Hz; 20–30 V DC |
| Connections | Screw terminal, 2 cables (24 AWG–18 AWG) |
| Mounting | Wall-mount |
| Dimensions (W x H x D) | 115 × 85 × 23.7 mm |
| Colour and finish | Glossy white |
| Material | ABS |
| Operating ambient temperature | 0–50 °C |
| Relative humidity (ambient) | 0–95 % |
| Controller compatibility | EcoStruxure Building Operation SmartX Room Purpose Controller programmable controllers |
| Standards | UL 916; FCC part 15 class B |
| Certifications | CE (EN 61000-6-2, EN 61000-6-3, EN 61326-1); RCM; EAC; ICES-003; cULus |
What the SLAWLXX does in a room
A room unit combines a sensing element and an operator face in one wall-mounted housing. The SLAWLXX measures temperature and passes the result to the room controller as an analogue signal, while the face gives the occupant a way to see the value or adjust the set point. With temperature alone, it is for rooms where humidity control is not part of the control strategy.
The datasheet lists a temperature setting range of 10–35 °C and an operating ambient range of 0–50 °C. Place the unit on an internal wall, away from direct sun, supply-air diffusers and warm equipment, so that the reading represents the occupied zone and not a local hot or cold spot.
Information to send with an RFQ for the SLAWLXX
- Exact reference SLAWLXX and quantity.
- Housing colour and face type required.
- Measurement needed: temperature only, or temperature and humidity.
- Controller type and output scaling.
- Delivery location and project schedule.
Documents and quotation
The manufacturer datasheet for the SLAWLXX is attached on this page and carries the specification summarised above. Check the revision date printed on it against your project documents before you rely on a figure.
Send us the reference SLAWLXX, the quantity and the delivery location, and Seven Star LLC will reply to your request. We are an independent supplier based in Muscat and we confirm availability and lead time per enquiry.
Other Models in the Se Sla Room Sensors Range
Seven Star LLC supplies models from the Se Sla Room Sensors range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric SLABTXX SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
| Schneider Electric SLASXX2 SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
| Schneider Electric SLAWLX2 SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
| Schneider Electric SLAWLXX SpaceLogic SLA Room Sensor | HVAC & Combustion | You are viewing this model |
| Schneider Electric SLAWTX2 SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
| Schneider Electric SLAWTXX SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
| Schneider Electric SLAWXX2 SpaceLogic SLA Room Sensor | HVAC & Combustion | View details |
Datasheets & Documents
- Datasheet Schneider Electric SLAWLXX Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric SLAWLXX SpaceLogic SLA Room
Answers from our engineering team on installation, compatibility and integration.
01What does the SLAWLXX measure?
It measures temperature. No humidity element is listed for this reference.
02What display does the SLAWLXX have?
A 2 inch LCD with plus, minus and arrow buttons.
03What outputs does the SLAWLXX provide?
Analogue outputs: one 0-10 V for fan speed and one configurable 0-5 V or 0-10 V output.
04What supply does the SLAWLXX need?
24 V AC at 50-60 Hz or 20-30 V DC, with screw terminals for two cables of 24 to 18 AWG.
05Which controllers is the SLAWLXX listed for?
The datasheet lists EcoStruxure Building Operation SmartX Room Purpose Controller programmable controllers as the compatible range.