Brand: Schneider Electric
Schneider Electric XA2EG43 XA2E key selector, 2 pos, 2 NO
Description
XA2EG43: XA2E key selector switch, 2 positions 90°, 2 NO
The XA2EG43 is a Schneider Electric Harmony XA2 complete key selector switch in the XA2E plastic series. It has 2 positions 90°, a stay-put operator and 2 NO, and it is operated with key number 455. The key can be withdrawn in the left and right positions. Seven Star LLC supplies the XA2EG43 in Oman and the GCC as an independent supplier in Muscat.
The datasheet used for this page is dated 8 Nov 2026 and shows the reference as discontinued: discontinuation is dated 9 Jan 2026 and end of service 1 Jul 2026. Treat availability as stock-dependent and ask about replacement options when you enquire. The key switch is a deliberate-access device: only a person holding the key can change the selected position.
Technical specifications of the XA2EG43
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / XA2EG43 |
| Range / short name | Harmony XA2 / XA2 |
| Product type | Complete selector switch |
| Component name | XA2E |
| Bezel / collar material | Plastic / Plastic |
| Operator type | Stay put |
| Operator profile | Key switch |
| Operator positions | 2 positions 90° |
| Key number / withdrawal | 455 / Left and right |
| Contacts | 2 NO |
| Contact operation | Slow-break |
| Mounting diameter | 22.5 mm |
| Panel fixing centre | >= 30 x 40 mm (panel) – thickness: 1–5 mm |
| Fixing nut torque | Fixing nut: 2–2.4 N.m |
| Terminals | Screw clamp, ≤ 2 × 1.5 mm²; Screw clamp, ≤ 1 × 2.5 mm²; Screw clamp, ≥ 1 × 0.5 mm²; Faston terminals, connection size: 6.3 mm |
| Terminal tightening torque | 0.8 N.m |
| Short-circuit protection | 10 A fuse type gL conforming to IEC 60269-1 |
| Conventional thermal current [Ith] | 10 A |
| Rated insulation voltage [Ui] | 600 V |
| Rated impulse withstand [Uimp] | 6 kV conforming to IEC 60947-1 |
| Rated operational current [Ie] | 3 A at 240 V, AC-15, A600; 0.27 A at 250 V, DC-13, Q600 |
| Mechanical durability | 100000 cycles |
| Electrical durability | 500000 cycles, AC-15, 3 A at 230 V, operating rate <60 cyc/mn, load factor: 0.5; 500000 cycles, DC-13, 0.2 A at 110 V, operating rate <60 cyc/mn, load factor: 0.5 |
| Dimensions (W x H x D) | 30 mm x 42 mm x 85.7 mm |
| Net weight | 0.078 kg |
| Operating temperature | -20–55 °C |
| Storage temperature | -40–70 °C |
| Protection | IP54 conforming to IEC 60529; IK03 conforming to IEC 60529 |
| Overvoltage category | Class I conforming to IEC 536 |
| Vibration resistance | 10 gn (f= 40–500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 70 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
| Standards | IEC 60947-1; GB 14048.1; GB 14048.5; IEC 60947-5-1 |
| Certifications | CE; CCC |
Key, positions and withdrawal on the XA2EG43
The datasheet lists key number 455 and withdrawal in the left and right positions. With withdrawal at both ends, the key can be taken out whichever of the two positions is selected, so either state can be locked in. The switch has 2 positions 90°; the handle is a key cylinder rather than a lever.
Treat key number as a part of the order, not an afterthought: all switches that must share one key need the same number, while switches that must not share a key need different ones. Ask which key arrangement your site rule uses before ordering.
Mounting and wiring of the XA2EG43
The body fits a 22.5 mm panel hole with a fixing-nut torque of 2–2.4 N.m. Overall size is 30 mm wide, 42 mm high and 85.7 mm deep and the net weight is 0.078 kg. The extra depth compared with a lever selector is the key cylinder, so check clearance behind the door. Wiring goes to screw clamp terminals for up to 2 x 1.5 mm² or 1 x 2.5 mm² (minimum 0.5 mm²), or 6.3 mm Faston tabs, tightened to 0.8 N.m.
The 2 NO contacts are normally open: with two contacts, each closes on a different side. Mark the schematic with the key number and the position used for each contact.
Electrical ratings and life of the XA2EG43
The rated operational current is 3 A at 240 V AC-15 and 0.27 A at 250 V DC-13; rated insulation voltage is 600 V and impulse withstand voltage 6 kV. A 10 A gL fuse is named as short-circuit protection. Electrical durability is 500000 cycles at 3 A AC-15 / 230 V and 500000 cycles at 0.2 A DC-13 / 110 V. Mechanical durability is 100000 cycles, noticeably lower than a push-button because a key cylinder is a heavier mechanism.
Key switches are normally used for infrequent changes of mode, so that figure is usually adequate; they are not meant for rapid cycling.
Where the XA2EG43 is used in Oman and the GCC
Key selectors restrict who can change a mode: bypass or override switches on safety interlocks, local-remote selection on pump and compressor panels, test or maintenance modes, and access control on machine guards. On Gulf sites with contractors on shift, a key held by the supervisor prevents a casual change.
The XA2EG43 has a front rating below that of push-buttons, so in sandy, humid or wash-down areas use it inside a closed enclosure or under a cover, and keep the key cylinder clean.
Commissioning and spares for the XA2EG43
As the datasheet marks this reference as discontinued, spares for existing key-operated panels are the likely need. Match key number, positions, contact count and withdrawal position with the unit being replaced, since two key switches that look the same can behave differently.
After installation, test the switch with the key in each position, confirm withdrawal behaves as intended and record who holds the keys. Lubricate or clean the cylinder only with products suitable for plastic and metal locks, and keep a spare key set in a controlled place together with the reference this unit in the panel records.
Information to send with an RFQ for the XA2EG43
- Full reference (this unit) and quantity, and whether it is a spare or part of a new build.
- Key number required (the datasheet lists 455), number of positions, and key withdrawal position.
- Control voltage and current of the circuit the contacts will switch.
- Panel cut-out size and thickness.
- Delivery location in Oman or the GCC and the required date.
Documents and quotation
The manufacturer datasheet for the XA2EG43 is attached on this page and carries the full specification summarised above. Check the revision date on the datasheet against your project requirement.
To request a quotation, send the part number XA2EG43, the quantity and your delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier.
Other Models in the Se Xa2e Key Selector Range
Seven Star LLC supplies models from the Se Xa2e Key Selector range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric XA2EG21 XA2E key selector, 2 pos, 1 NO | Automation Accessories | View details |
| Schneider Electric XA2EG33 XA2E key selector, 3 pos, 2 NO | Automation Accessories | View details |
| Schneider Electric XA2EG43 XA2E key selector, 2 pos, 2 NO | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric XA2EG43 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric XA2EG43 XA2E key selector, 2
Answers from our engineering team on installation, compatibility and integration.
01What is the XA2EG43?
A Harmony XA2E complete key selector switch with 2 positions 90°, stay-put action and 2 NO, for a 22.5 mm panel hole.
02Which key does the XA2EG43 use?
The datasheet lists key number 455, with key withdrawal in the left and right positions.
03What are the contact ratings of the XA2EG43?
3 A at 240 V AC-15 and 0.27 A at 250 V DC-13 with a 10 A gL fuse as short-circuit protection.
04Is the XA2EG43 still available?
The datasheet shows it as discontinued on 9 Jan 2026, with end of service on 1 Jul 2026. Confirm stock before ordering.
05What are the size and protection of the XA2EG43?
It measures 30 mm wide, 42 mm high and 85.7 mm deep and has IP54 at the front, with operating temperature -20–55 °C.