Schneider Electric TM3AM6G Modicon TM3 4AI/2AO Spring Module

Description

TM3AM6G: TM3 4-input, 2-output analogue module with spring terminals

The TM3AM6G is the spring-terminal version of the TM3 analogue mixed module, with four inputs and two outputs that can each be set for 4–20 mA, 0–20 mA, 0–10 V or ±10 V. It connects to Modicon M221, M241, M251 and M262 controllers over the TM3 expansion bus.

Electrically TM3AM6G matches TM3AM6; what changes is the terminal technology and a slightly lower weight of 0.1 kg. Spring terminals shorten wiring time and resist loosening under vibration, which is why many panel builders prefer the G versions. Seven Star LLC supplies the this unit in Oman and the GCC as an independent supplier in Muscat.

Why choose the spring version, the TM3AM6G

Spring clamps hold the conductor with constant pressure and need no re-tightening, which cuts commissioning time and the maintenance round for loose screws in panels that experience thermal cycling. The datasheet describes ten removable 1.5 mm² terminals at 3.81 mm pitch, and it lists the conductor range for the TM3 family as 0.14 to 1.5 mm² (26 to 16 AWG).

If the site standard is ferrules with screw terminals, TM3AM6 is the matching reference. Do not mix the two in a panel schedule without checking which one the electrician will receive.

Technical specifications of the TM3AM6G

Parameter Specification
Manufacturer / part number Schneider Electric / TM3AM6G
Range of product Modicon TM3
Product type Analogue input/output module
Compatible controllers Modicon M221, M241, M251, M262
Analogue inputs 4: 4–20 mA, 0–20 mA, 0–10 V, ±10 V
Analogue outputs 2: 4–20 mA, 0–20 mA, 0–10 V, ±10 V
Resolution 12 bits (11 bits + sign)
Input overload 13 V (voltage) or 40 mA (current), continuous
Input impedance 50 Ω or less (current); 1 MΩ or more (voltage)
Load impedance on outputs 1 kΩ (voltage); 300 Ω (current)
Conversion time 1 ms + 1 ms per channel + controller cycle
Absolute accuracy ±1 % of full scale; ±0.2 % at 25 °C
Repeat accuracy ±0.5 % FS on inputs
Temperature drift ±0.01 % FS/°C
Non-linearity ±0.2 % FS
Insulation 1500 V AC between input/output and supply; 500 V AC to internal logic
Current consumption 45/55 mA at 5 V DC (no load/full load); 55/100 mA at 24 V DC
Terminals 10 x 1.5 mm² removable, pitch 3.81 mm
Dimensions (W x H x D) 23.6 x 90 x 70 mm
Net weight 0.1 kg
Mounting 35 mm DIN rail (TH35-15, TH35-7.5) or panel with fixing kit
Operating temperature −10 to 55 °C horizontal; −10 to 35 °C vertical
Storage temperature −25 to 70 °C
Humidity 10–95 % without condensation
Protection IP20
Certifications listed CE, UKCA, RCM, EAC, cULus, cULus HazLoc
Shock / vibration 15 gn for 11 ms; 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz on DIN rail

Selection checklist and RFQ details for the TM3AM6G

Make sure that:

  • spring terminals suit the cable sizes of 0.14 to 1.5 mm²
  • the signal ranges of every transmitter and actuator are covered
  • the controller can accept the module on its TM3 bus
  • you are not ordering the screw version by mistake

Include the quantity, controller model and delivery site in the RFQ.

The TM3AM6G in the TM3 analogue group

Reference Channels Terminals Net weight
TM3AM6 4 in / 2 out Removable, 3.81 mm pitch (style not named) 0.11 kg
TM3AM6G 4 in / 2 out Spring 0.1 kg
TM3AQ2 0 / 2 out Screw, 11 x 2.5 mm² 0.115 kg
TM3AQ2G 0 / 2 out Spring, 11 x 2.5 mm² 0.1 kg
TM3TI4G 4 temperature/analogue in Screw per datasheet text 0.1 kg
TM3TM3G 2 in / 1 out Spring, 11 x 2.5 mm² 0.1 kg

Analogue performance of the TM3AM6G

All four ranges are available on both inputs and outputs: 4–20 mA, 0–20 mA, 0–10 V and ±10 V. Resolution is 12 bits (11 bits plus sign), accuracy is ±1 % of full scale and ±0.2 % at 25 °C, repeat accuracy on inputs is ±0.5 %, non-linearity is ±0.2 % and temperature drift is ±0.01 % per °C.

Conversion time is 1 ms plus 1 ms per channel plus one controller cycle, which is acceptable for typical pressure, level, flow and temperature transmitters.

Applications of the TM3AM6G in Oman and the GCC

This module is a practical choice for HVAC plants, pump stations, desalination auxiliaries, process skids and generators where a small number of analogue signals need to be read and a couple of set-points must be written back, such as a control valve at 4–20 mA or a drive reference at 0–10 V.

Approvals listed are CE, UKCA, RCM, EAC, cULus and cULus HazLoc, with IEC 61131-2 as the standard.

Mounting dimensions of the TM3AM6G

The module is 23.6 mm wide, 90 mm high and 70 mm deep and weighs 0.1 kg. It latches on a TH35-15 or TH35-7.5 rail or is screwed to a panel with a fixing kit. The module is IP20, with temperature limits of −10 to 55 °C horizontal and −10 to 35 °C vertical.

Leave room above and below the stack for wiring and airflow, particularly in Gulf panels where internal temperature is already high.

Supply and bus load of the TM3AM6G

Consumption at 5 V DC is 45 mA with no load and 55 mA at full load, and at 24 V DC it is 55 mA and 100 mA respectively. Insulation is 1500 V AC between input or output and supply and 500 V AC to the internal logic. Twisted shielded pairs up to 30 m are specified for the signal cables.

Because the module takes current from both the 5 V bus and the 24 V bus of the controller, the sum for all fitted modules must stay within what the controller or the receiver module offers.

Documents and quotation

The Schneider Electric datasheet for the this unit is attached on this page, so you can compare the listed values with your design before ordering.

To request a quotation for the TM3AM6G, send the quantity, delivery destination and any project reference through the RFQ form. Seven Star LLC supplies Schneider Electric automation products in Oman and the GCC as an independent supplier based in Muscat, and we confirm stock status and lead time against your request.

Other Models in the Se Tm3 Analog Range

Seven Star LLC supplies models from the Se Tm3 Analog range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TM3AM6 Modicon TM3 4AI/2AO Analog ModuleLogic ControllersView details
Schneider Electric TM3AM6G Modicon TM3 4AI/2AO Spring ModuleLogic ControllersYou are viewing this model
Schneider Electric TM3AQ2 Modicon TM3 2 Analog Output ModuleLogic ControllersView details
Schneider Electric TM3AQ2G Modicon TM3 2AO Spring ModuleLogic ControllersView details
Schneider Electric TM3TI4G Modicon TM3 4-Ch Temperature ModuleLogic ControllersView details
Schneider Electric TM3TM3G Modicon TM3 2 Temp In 1 AO ModuleLogic ControllersView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric TM3AM6G Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric TM3AM6G Modicon TM3 4AI/2AO

Answers from our engineering team on installation, compatibility and integration.

01How does the TM3AM6G differ from the TM3AM6?
Both have 4 analogue inputs and 2 outputs with the same ranges. The TM3AM6G is the spring-terminal reference and weighs 0.1 kg against 0.11 kg.
02Which signal types does the TM3AM6G support?
Current 4–20 mA and 0–20 mA, and voltage 0–10 V and ±10 V on both inputs and outputs.
03What is the conversion time of the TM3AM6G?
1 ms plus 1 ms per channel plus one controller cycle.
04What is the insulation of the TM3AM6G?
1500 V AC between inputs or outputs and the supply, and 500 V AC between inputs or outputs and the internal logic.
05What cable does the TM3AM6G require?
Twisted shielded pairs of up to 30 m for the input and output circuits, into 0.14 to 1.5 mm² spring terminals.