Brand:

Tektronix Keithley 2460 SourceMeter SMU 100 V 7 A 100 W

Description

2460 is the Keithley high-current SourceMeter source measure unit (SMU) from Tektronix: a four-quadrant source and sink covering up to 105 V and 7 A (DC or pulse) at 100 W maximum, with 6.5-digit measurement and a 5 in. capacitive touchscreen.

One instrument for source, load and meter

The datasheet describes the 2460 as combining a precision power supply with voltage and current readback, a true current source, a digital multimeter, a precision electronic load and a trigger controller. Because it sinks as well as sources, it can charge and discharge a cell, load a DC-DC converter, or sweep the I-V curve of an LED, diode, solar cell or power MOSFET with one set of leads.

Four Quickset modes (source and measure combinations) shorten set-up, and icon menus with context help are said to cut the steps needed to configure a test by as much as 50 percent. Programming is by SCPI or by TSP Lua scripts executed on the instrument.

Key features as printed in the datasheet

  • Basic measurement accuracy 0.012 % at 6.5 digits.
  • Voltage ranges 200 mV to 100 V; current ranges 1 µA to 7 A.
  • Front banana jacks and rear mass-termination screw connections.
  • Interlock input, over-voltage protection and over-temperature standby.
  • Front USB memory port; TSP-Link expansion for multi-unit systems.

Technical specification

Voltage ranges (1-year accuracy, 23 ±5 °C)

Parameter Specification
200 mV range Source 0.015 % + 200 µV; measure 0.012 % + 200 µV; maximum 7.35 A
2 V range Source 0.015 % + 300 µV; measure 0.012 % + 300 µV; 7.35 A
7 V range Source 0.015 % + 2.4 mV; measure 0.015 % + 1 mV; 7.35 A
10 V and 20 V ranges Source 0.015 % + 2.4 mV; maximum 5.25 A and 4.20 A
100 V range Source 0.015 % + 15 mV; measure 0.015 % + 5 mV; 1.05 A
Measure input resistance >10 GΩ

Current ranges (1-year accuracy)

Parameter Specification
1 µA range Source 0.025 % + 1 nA; measure 0.025 % + 700 pA; 105 V
1 mA range Source 0.020 % + 150 nA; measure 0.020 % + 100 nA; 105 V
100 mA range Source 0.020 % + 15 µA; measure 0.020 % + 10 µA; 105 V
1 A range Source 0.050 % + 750 µA; measure 0.050 % + 500 µA; 105 V
4 A and 5 A ranges Source 0.100 % + 3 mA; maximum 21 V and 10.5 V
7 A range Source 0.150 % + 6 mA; measure 0.150 % + 5 mA; 7.35 V
Temperature coefficient ±(0.10 x accuracy specification) per °C outside 18 to 28 °C

Resistance, power and control

Parameter Specification
Resistance, 2 kΩ range 0.05 % + 0.3 Ω normal; 0.04 % + 0.1 Ω enhanced (test current 1 mA)
Resistance, 20 MΩ range 0.14 % + 1000 Ω normal (test current 1 µA)
Maximum output power 100 W, four-quadrant source or sink
Source limits ±7.35 V at 7 A; ±10.5 V at 5 A; ±21 V at 4 A; ±105 V at 1 A
Regulation Voltage 0.01 % of range line, 0.01 % + 100 µV load
Output settling Under 200 µs to 0.1 %, 20 V range, 100 mA limit (typical)
Over-voltage protection User selectable, 5 % ±0.5 V; factory default none
Digital I/O 6 lines, 9-pin D; 0.7 V low, 3.7 V high; handler start/end of test

General

Parameter Specification
Display 5 in. capacitive touch TFT, 800 x 480
Interfaces LAN/LXI 1.5, USB-TMC, USB host, GPIB via accessories, TSP-Link
Power 100 to 240 V RMS, 50/60 Hz; 350 VA maximum
Size Bumpers and handle: 106 x 255 x 425 mm (H x W x D); without: 88 x 213 x 403 mm
Weight 4.75 kg with bumpers and handle; 4.35 kg without
Environment Indoor, non-residential; 0 to 50 °C, 70 % RH to 35 °C; storage -25 to 65 °C; up to 2000 m
Safety as printed CE; NRTL listed to UL61010-1 and UL61010-2-30; MIL-PRF-28800F Class 3 vibration
Warm-up 1 hour to rated accuracy

Ordering and extras

The order code 2460 covers the 100 V, 7 A, 100 W instrument. Supplied with it: 2460-KIT screw connector, CS-1616-3 interlock connector, a TSP-Link/Ethernet cable, a USB cable, a clip-on safety test lead set and a power cord. Extended warranty plans (3 or 5 years) and KeithleyCare calibration plans are sold as services. Note that the guaranteed accuracy figures assume the 2460-KIT screw terminal accessory is used.

Set-up and safety notes

Allow one hour of warm-up and keep the unit indoors between 0 and 50 °C; it is rated for non-residential indoor use. Wire the safety interlock when working above the voltages your lab considers hazardous, and use four-wire sensing for low-resistance or high-current work. Over-voltage protection is off by default, so set it before connecting a sensitive device under test. The datasheet states all specifications are guaranteed with the output on.

Where an SMU earns its place in the Gulf

Battery and cell testing, LED and solar-panel characterisation, and SiC or GaN power-device checks are the uses the datasheet cites. For Gulf buyers this typically means university and college labs, solar-inverter service benches and electronics repair houses. It is an indoor bench instrument with no ingress or hazardous-area rating, so protect it from dust and keep it in an air-conditioned room.

Probes, racks and software

Keithley lists 5805 Kelvin spring probes, 5808 single-pin Kelvin probes, 2460-BAN cable, 7007-1 GPIB cable, 4299-8 and 4299-9 rack kits, and I-V Tracer, KickStart and ACS Basic software. A 6.5-digit companion such as the DMM6500 shares the TSP language. See the Portable Test and Measurement category.

Selection and installation notes

Test and measurement instruments are selected from the accuracy, the range and the interfaces the work needs. Allow the warm-up time, use leads and probes rated for the voltage and category of the circuit, keep the inputs inside the stated limits and keep the calibration current according to your quality system. Record the settings used for any test that must be repeated later.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Frequently asked questions

What are the voltage, current and power limits?

Up to 105 V and up to 7.35 A, with 100 W maximum output power in four-quadrant source or sink operation.

Can it act as an electronic load?

Yes. It sources and sinks in all four quadrants, so it can absorb power as well as supply it.

How is it programmed?

By SCPI commands or by TSP scripts that run on the instrument itself.

How long should it warm up?

The datasheet states 1 hour to reach rated accuracy.

Is Seven Star LLC a Tektronix distributor?

No. Seven Star LLC is an independent supplier in Muscat that sources Tektronix products on request.

Documents and quotation

Download the official Tektronix datasheet for 2460 from this page. As an independent supplier based in Muscat, Seven Star LLC supplies Tektronix items on request: use the quote form with the quantity you need. Check every value in the document against your own specification before you order. Browse similar items in the category.

Datasheets & Documents
  • PDF Datasheet Keithley 2460 datasheet (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Tektronix is an American maker of test and measurement instruments, founded in 1946 in Portland, Oregon, by Howard Vollum and Jack Murdock. Its early triggered-sweep oscilloscopes set the pattern for modern scopes. Tektronix is headquartered in Beaverton, Oregon, joined Danaher in 2007 and has been part of Fortive since 2016; Keithley is a Tektronix company.

Seven Star LLC is an independent supplier in Muscat. We list Tektronix and Keithley instruments with the official datasheet beside each listing, for laboratories, workshops and training centres in Oman and the GCC.

Tektronix company profile

Founded 1946, Portland, Oregon, USA
Founders Howard Vollum and Jack Murdock
Headquarters Beaverton, Oregon
Ownership Fortive, since 2016 (Danaher from 2007)
Product families MSO 2, 4, 5 and 6 Series mixed-signal oscilloscopes, TBS basic oscilloscopes, AFG arbitrary function generators, real-time spectrum analysers, probes, Keithley source measure units and DMMs

Milestones

  • 1946: Vollum and Murdock found Tektronix.
  • 2007: Danaher acquires Tektronix.
  • 2016: Tektronix becomes part of Fortive.

Tektronix product series

Oscilloscopes include the TBS2104 100 MHz digital storage oscilloscope, the MSO24 2 Series and MSO44B 4 Series B mixed signal oscilloscopes and the MDO34 3 Series mixed domain oscilloscope with built-in spectrum analyzer.

Meters and sources include the Keithley DMM6500 6.5-digit touchscreen multimeter, the DMM7510 7.5-digit sampling multimeter, the Keithley 2460 SourceMeter (100 V, 7 A, 100 W), the DMM4050 bench multimeter, the PA1000 single-phase power analyzer and the AFG3022C two-channel arbitrary function generator.

Where Tektronix instruments are used

Electronics design and repair, power electronics and drive testing, component characterisation, university and training labs and calibration rooms.

Tektronix products we list

Family Examples
Portable Test & Measurement DMM4050 6.5-Digit Precision Bench Multim…, Keithley 2460 SourceMeter SMU 100 V 7 A…, Keithley DMM6500 6.5-Digit Touchscreen M…, Keithley DMM7510 7.5-Digit Sampling Mult…, MDO34 3 Series 4-Channel Mixed Domain Os…, MSO24 2 Series 4-Channel Mixed Signal Os…, MSO44B 4 Series B 4-Channel Mixed Signal…

Ordering Tektronix instruments: what we need

Send the model, bandwidth and channel options, software licences, probes and accessories, the supply voltage and whether a calibration certificate is required.

Facts checked against Tektronix company history and Fortive filings, October 2026.

Frequently Asked Questions

What are the voltage, current and power limits?
Up to 105 V and up to 7.35 A, with 100 W maximum output power in four-quadrant source or sink operation.
Can it act as an electronic load?
Yes. It sources and sinks in all four quadrants, so it can absorb power as well as supply it.
How is it programmed?
By SCPI commands or by TSP scripts that run on the instrument itself.
How long should it warm up?
The datasheet states 1 hour to reach rated accuracy.
Is Seven Star LLC a Tektronix distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources Tektronix products on request.