Brand: Sungrow
Sungrow SG50CX-P2 50 kW Multi-MPPT String Inverter
Description
A 50 kW four-MPPT string inverter in the SG36/40/50CX-P2 series
The Sungrow SG50CX-P2 is the largest of the SG36/40/50CX-P2 string inverters: 50 kW rated, 55 kVA maximum apparent power, four independent MPPTs and up to 70 kWp of recommended PV input. It shares a datasheet with the SG36CX-P2 and SG40CX-P2, and all three use the same 645 x 575 x 245 mm enclosure.
Sungrow quotes 98.5 percent maximum efficiency, a 34 percent lighter body for easy handling, 15 A DC current input compatible with 500 W-plus modules, plug-and-play buckle installation, IP66, C5 anti-corrosion and AFCI 2.0, with built-in PID recovery and smart IV curve diagnosis.
SG50CX-P2 features
- 4 MPPTs with two strings each at 30 A per MPPT
- Peak efficiency 98.5 percent, European weighted 98.3 percent
- Shading optimization mode, PID recovery inside, IV curve diagnosis tool
- Buckle-style plug-and-play fitting; body 34 percent lighter than before
- Surge protection DC Type I+II, AC Type II; AFCI 2.0 arc-fault function
- Sealed to IP66 with C5 corrosion rating; grid fault log for remote service
- AC terminal accepts 35 to 50 mm2 with OT or DT lugs
SG50CX-P2 technical specifications
Rating comparison (shared datasheet)
| Parameter | SG36CX-P2 | SG40CX-P2 | SG50CX-P2 |
|---|---|---|---|
| Design AC output current at 230 V | 52.17 A | 58 A | 72.5 A |
| Recommended max. PV input power | 50.4 kWp | 56 kWp | 70 kWp |
| Net weight | 40 kg | 40 kg | 41 kg |
| Design AC output power | 36 kW | 40 kW | 50 kW |
| Highest AC apparent power | 40 kVA | 44 kVA | 55 kVA |
| Highest AC output current | 60.2 A | 66.9 A | 83.6 A |
Common data, all three ratings
| Parameter | Specification |
|---|---|
| THD / power factor | Less than 3 pct / above 0.99, 0.8 leading – 0.8 lagging |
| Protective functions | Grid monitoring, reverse polarity, AC short-circuit, leakage current, ground fault, DC switch, string current monitoring, AFCI, PID recovery; DC Type I+II and AC Type II SPD |
| Outline W x H x D | 645 x 575 x 245 mm |
| Topology / protection / corrosion | Transformerless / IP66 / C5 |
| Temperature, operating / humidity | -30 C to 60 C / 0-100 pct no condensation |
| Cooling / altitude | Smart forced air cooling / 4000 m |
| Night power consumption | Less than 7 W |
| Comms | RS485; optional WLAN and Ethernet; LED, Bluetooth + app |
| DC / AC connection | Evo2 (max. 6 mm2) / OT terminal 16-35 mm2 or OT/DT terminal 35-50 mm2, cable OD 18-38 mm |
| Compliance list (printed) | IEC 62109, IEC 61727, IEC 62116, VDE-AR-N 4105:2018, EN 50549-1, CEI 0-21, G99, IEC 63027 and others |
| Highest PV input voltage | 1100 V |
| Lowest / startup input voltage | 160 V / 200 V |
| Design PV input voltage | 600 V |
| MPPT voltage range | 160 V – 1000 V |
| Independent MPP inputs / strings per MPPT | 4 / 2 |
| Highest PV input current | 120 A (30 A x 4) |
| Highest DC short-circuit current | 160 A (40 A x 4) |
| Design AC voltage / range | 3 / N / PE, 220/380 or 230/400 V / 312 V – 480 V |
| Grid frequency | 50 Hz / 60 Hz |
| Highest / European efficiency | 98.5 pct / 98.3 pct |
Choosing 36, 40 or 50 kW
The 36, 40 and 50 kW models differ in output rating and recommended array (50.4, 56 and 70 kWp) while sharing the same housing. Check the AC cable size, which moves from 16-35 mm2 OT lugs to 35-50 mm2 OT or DT lugs at the top of the range, and the 83.6 A maximum output current when sizing breakers. As with other CX models, optimizer compatibility should be discussed with Sungrow before ordering.
Installation and operation notes
Wall-bracket mounting with the buckle design keeps installation simple for one or two people, at 40 to 41 kg. Cooling is smart forced air, so provide clearance. Commissioning is through Bluetooth and the app; RS485 is fitted and WLAN or Ethernet are optional. Use the user manual for the full-load MPPT voltage range and string design.
Where the SG50CX-P2 is used
It suits mid-size commercial and industrial roofs where 50 kW blocks are repeated, for example warehouses and factory sheds, and arrays of up to 70 kWp per inverter. The printed 60 C ambient limit and C5 rating suit hot sites, and DC Type I+II surge protection helps where lightning exposure is a concern. Confirm utility approval for each country separately.
Installation and selection notes
Design the string layout from the module data so that the voltage and current stay inside the inverter window over the temperature range at the site, and plan mounting with enough clear space for cooling. Check the AC cable size, the protection devices, the communication method and the local grid connection requirements before ordering, and keep the commissioning record for the warranty file.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any hoses, couplings or accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification before a purchase is confirmed. Ratings, flows, pressures and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related Sungrow items
Sungrow lists the SG33CX-P2 for smaller roofs, the SG125CX-P2 and SG150CX for larger blocks, and the SG10RT-P2 for small commercial systems.
Frequently asked questions
How many MPPTs does the SG50CX-P2 have?
Four, each with two strings and 30 A input current.
What is the recommended maximum PV power?
70 kWp for the 50 kW model.
What AC voltages are supported?
Three-phase 220/380 V or 230/400 V, 50 or 60 Hz.
What AC cable sizes can be used?
16-35 mm2 with OT terminals, or 35-50 mm2 with OT or DT terminals.
Is Seven Star LLC a distributor of Sungrow?
No. We are an independent supplier based in Muscat, and we source genuine Sungrow products for customers in Oman and the GCC when requested.
Documents and quotation
Manufacturer document: the SG36/40/50CX-P2 datasheet (Version 4), hosted on this page. Compare it with the instruction manual before you confirm the exact style or order code. Seven Star LLC supplies Sungrow items from Muscat to buyers in Oman and the wider GCC; send the model, option code and quantity through the quotation form for availability. Pricing is on request, and every rating or approval should be re-checked against the current maker documents. More: Solar Power and the Sungrow brand page.
Datasheets & Documents
- Datasheet Sungrow SG36/40/50CX-P2 datasheet (Version 4) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Sungrow is a Chinese manufacturer of power conversion equipment, founded in 1997 and headquartered in Hefei. Its products include solar string and central inverters, energy storage systems, EV chargers and medium voltage stations for solar plants.
Seven Star LLC is an independent supplier in Muscat. We list Sungrow inverters and stations, each with the manufacturer datasheet, for solar installers and developers in Oman and the GCC.
Sungrow product series
Residential inverters include the SG3.0RS and SG5.0RS single-phase string inverters and the SG10RT-P2 three-phase inverter. Commercial string inverters include the SG33CX-P2, SG50CX-P2, SG125CX-P2 and SG150CX with multiple MPPTs.
For utility-scale plants there are the SG350HX 1500 V string inverter and the MVS3200-LV 3.2 MVA medium voltage turnkey station, and the AC22E-01 is a 22 kW AC charger for electric vehicles.
Where Sungrow equipment is used
Villa and small commercial roofs, larger commercial roofs and carports, ground-mounted utility-scale solar blocks, and car parks and fleet sites that need EV charging.
Ordering Sungrow equipment: what we need
Send the model, grid voltage and frequency, array layout with string count and peak power, site temperature range and any monitoring or communication needs. Each page carries the manufacturer datasheet so limits can be checked first.
Browse Sungrow products by category: Solar Power.
Related products
Frequently Asked Questions
Four, each with two strings and 30 A input current.
70 kWp for the 50 kW model.
Three-phase 220/380 V or 230/400 V, 50 or 60 Hz.
16-35 mm2 with OT terminals, or 35-50 mm2 with OT or DT terminals.
No. We are an independent supplier based in Muscat, and we source genuine Sungrow products for customers in Oman and the GCC when requested.

Reviews
There are no reviews yet.