Brand:

KROHNE OPTISONIC 8300 Ultrasonic Flowmeter for Hot Gas and Steam

Description

Two-path ultrasonic flowmeter for superheated steam and cryogenic gas

The KROHNE OPTISONIC 8300 is a two-path ultrasonic flowmeter for gases under extreme conditions: superheated steam and hot gas up to +593 C (+1100 F) and cryogenic gas down to low temperatures with the OPTISONIC 8300 LT variant. Pressure can reach 200 barg (1465 psig), and the full-bore carbon steel sensor has no moving parts, wear or pressure loss.

Accuracy is better than 1 percent of measured value above DN150, and the data sheet gives +/-1.5 percent for DN100 and a repeatability below +/-0.2 percent. An optional integrated flow computer calculates mass flow and enthalpy to IAPWS-IF97 from external pressure and temperature inputs, which supports energy balancing. OPTICHECK technology allows on-site verification.

Technical specifications

Parameter Specification
Model OPTISONIC 8300 (high temperature) and 8300 LT (low temperature)
Principle Ultrasonic transit time, two parallel paths
Media Gases, superheated steam, cryogenic gas
Process temperature -25 to +593 C / -13 to +1100 F (page); description states -200 to +593 C
Pressure Max. 200 barg / 1465 psig
Flange sizes EN 1092-1 DN100 to DN1000; ASME 4 to 40 in
Sensor material Carbon steel (A105 Gr. B)
Accuracy Better than 1 % of MV above DN150; DN100 +/-1.5 %
Repeatability Below +/-0.2 %
Outputs 4 to 20 mA, pulse, frequency, status, limit switches; HART, FOUNDATION Fieldbus, Modbus RTU
Hazardous area as printed ATEX, cQPSus, IECEx, NEPSI; CRN

Where it is used

Named uses include turbine and boiler performance, steam allocation in chemical plants, custody transfer of steam where permitted, and boil-off gas in LNG loading. Cryogenic uses include air-separation cold boxes and general cryogenic gas handling.

There is no periodic maintenance or recalibration claimed in the product highlights, and the Ex d certified 316L connection box suits plant environments.

Planning the installation

The converter measures volume, enthalpy and mass at constant density, and pressure and temperature signals from the plant improve the mass result. Give the steam or gas composition, pressure and temperature ranges, line size and flange standard.

The hosted TD is dated 2015 (R02), so ask for the current revision and certificate list. A derived reminder: insulation of hot pipes and the permitted ambient temperature at the converter must be checked at design stage. Steam lines should be installed with condensate drainage so that wet steam does not disturb the ultrasonic signal, and a long straight run before the meter improves repeatability in disturbed flow profiles. Commissioning normally includes entering the line size, wall thickness and the expected gas properties, and checking the signal quality indicators reported by the diagnostics before the meter is released for billing or energy balancing.

Wiring and documentation matter on steam and cryogenic duty: record the line size, wall thickness, gas data and the pressure and temperature signals at commissioning, and keep the OPTICHECK verification report with the meter file. Where the meter is used for energy balancing, agree the allowed uncertainty with the plant operator before the order is placed.

Related KROHNE products: KROHNE OPTISONIC 3400 Ultrasonic Flowmeter, Krohne Optisonic 7300 Ultrasonic Gas Flowmeter, KROHNE OPTISONIC 6300 Clamp-On Ultrasonic Flowmeter, KROHNE OPTIFLUX 2300 Electromagnetic Flowmeter, Krohne Optiflux 4300 Electromagnetic Flowmeter and KROHNE OPTIFLUX 2000 Electromagnetic Flowmeter.

Documents and quotation

The manufacturer document (KROHNE OPTISONIC 8300 technical datasheet (EN)) is attached to this page as a PDF. Send the complete type code or part number you need through the quotation form and we will reply with availability and delivery terms; please confirm the size, temperature range and flow computer option against the plant specification before ordering. More in Flowmeters.

Datasheets & Documents
  • PDF Datasheet KROHNE OPTISONIC 8300 technical datasheet (EN) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KROHNE is the German flow and level measurement company founded in Duisburg in 1921 as Ludwig Krohne & Sohn. Its first customers were Ruhr steel producers, for whom it built variable area flowmeters. KROHNE dates the first electromagnetic flowmeter for industrial process measurement to 1952. It is still family-owned and headquartered in Duisburg.

Seven Star LLC is an independent supplier in Muscat. We list KROHNE electromagnetic, Coriolis, ultrasonic and variable area flowmeters, radar level transmitters and flow computers, and supply them to water utilities, oil and gas and process plants in Oman and the GCC by order code.

KROHNE company profile

Established 1921, Duisburg, Germany, as Ludwig Krohne & Sohn
Early products Variable area flowmeters for hardening furnaces in the Ruhr steel industry
Milestone 1952: first electromagnetic flowmeter for industrial process measurement, according to KROHNE
Product families Electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters, radar and guided radar level, flow computers and metering systems, analysers

Milestones

  • 1921: Ludwig Krohne starts making variable area flowmeters in Duisburg for hardening furnaces in the Ruhr steel industry.
  • 1952: First electromagnetic flowmeter for industrial process measurement, according to KROHNE.
  • 1980: First ultrasonic flowmeter delivered to Shell for crude oil measurement.
  • 1985: Development and production of Coriolis mass flowmeters begins.
  • 1994: First Coriolis mass flowmeter with a single straight measuring tube.
  • 1996: ALTOSONIC V, the first ultrasonic meter for custody transfer of liquids.

KROHNE products we list

Family Models Typical use
Electromagnetic flowmeters OPTIFLUX 2000, 2100, 2300, 4100, 4300, WATERFLUX 3070, 3100, 3300 Water networks, wastewater, seawater intake and conductive process liquids
Coriolis mass flowmeters OPTIMASS 1400, 6400 Direct mass flow and density of hydrocarbons, chemicals and LPG
Ultrasonic flowmeters ALTOSONIC V12, OPTISONIC 3400, 6300 clamp-on, 7300 gas Gas custody transfer, liquid process flow and non-intrusive clamp-on checks
Variable area flowmeters H250 M40, DK800/R Simple, power-free flow indication for purge, sample and utility lines
Level OPTIFLEX 7200 guided radar, OPTIWAVE 5400, 7500, 1540, OPTISWITCH 5300 Level in tanks, separators and chemical storage, and point level switching
Flow computer SUMMIT 8800 Fiscal and custody transfer calculations for gas and liquid metering

The flowmeter principle follows the medium. Electromagnetic meters need a conductive liquid, have no moving parts and no pressure loss, and suit water and slurries. Coriolis meters measure mass flow and density directly, so they work for hydrocarbons and non-conductive liquids. Ultrasonic meters handle gas and large pipes, and multi-path designs such as the ALTOSONIC V12 are used for custody transfer. Variable area meters need no power at all and give a simple local reading.

Where KROHNE instruments are used

In Oman and the GCC, KROHNE flowmeters and level transmitters are used in water transmission and distribution, desalination, wastewater, oil and gas production and fiscal metering, refineries, petrochemical and chemical plants, and power stations.

Ordering KROHNE instruments: what we need

Send the complete KROHNE order code or the nameplate data. For a new meter, send the medium, the flow range, pressure and temperature, the pipe size and flange rating, the liner and electrode materials (for electromagnetic meters), the output and communication, and the hazardous area classification.

Facts checked against KROHNE company history (100th anniversary), October 2026.

FAQ

Questions about the KROHNE OPTISONIC 8300 Ultrasonic Flowmeter for Hot

Answers from our engineering team on installation, compatibility and integration.

01What temperatures can it measure?
Up to +593 C (+1100 F) for the standard unit; an LT version covers cryogenic gas.
02How accurate is it?
Better than 1 percent of measured value above DN150, with +/-1.5 percent for DN100.
03Can it calculate mass and enthalpy?
An optional integrated flow computer does so to IAPWS-IF97.
04Does it have moving parts?
No, it is a full-bore ultrasonic sensor with no moving parts or pressure loss.
05What size range is offered?
DN100 to DN1000 (4 to 40 in).