DST P110: a compact OEM transmitter for chillers, heat pumps and transport refrigeration

Danfoss 075G0003 is a DST P110 in the 0 to 10 bar sealed-gauge version with a 4 to 20 mA output. Danfoss Sensor Technology builds this model around MEMS pressure sensing in a welded stainless-steel media interface that is compatible with all refrigerants, with an ARM-based microcontroller that provides diagnostics and stable measurement for OEM installation.

The listed applications are data centres, chillers, transport and commercial refrigeration, variable-speed HVAC equipment, heat pumps and VRF systems. The outline is small and light, only 62 g according to the store entry, which helps when the sensor hangs from a copper line.

Technical specifications

Parameter Specification
Danfoss code number 075G0003
Type DST P110
Pressure range 0 to 10 bar (0 to 145 psi), sealed gauge
Output signal 4 to 20 mA, fault signal level 21.5 mA
Overload pressure 40 bar (580 psi)
Pressure connection 7/16-20 UNF female, SAE J513 45 degree flare, 27 mm hex
Electrical connection Round Packard Metri-Pack 150.2 series, 3 pin, black
Enclosure IP69K
Medium temperature -40 to 100 C
Ambient temperature -40 to 85 C
Compensated temperature range -40 to 100 C
Total error band 3 % of full scale inside the compensated range
Response time (max.) 2 ms
Housing / wetted material 304L / 304L/316L
Approvals as listed C UL US UL Recognized; CE
Net weight 0.062 kg
EAN 5715255228219

Reading the electrical data

Unlike the plug-in industrial AKS and MBS types, this code uses a round Metri-Pack connector, a sealed automotive-style interface that is common on OEM harnesses. The enclosure rating is IP69K, which allows high-pressure washdown, and the fault signal level of 21.5 mA lets a controller distinguish a sensor failure from a real pressure reading.

A total error band of 3 % inside the compensated range and a response time of 2 ms are the numbers to use for control-loop design. The overload pressure of 40 bar is four times the range, and the data sheet adds a high burst rating against pressure spikes.

Where it fits and what to confirm

This is an OEM device. Harness, mating connector and flare fitting must be chosen to match; the female SAE 45 degree flare 7/16-20 UNF port normally takes a deflator-pin fitting on a refrigeration line. Check the colour code and focus temperature range given in the data sheet, because Danfoss groups the different DST P110 codes by range.

Seven Star LLC is an independent supplier in Muscat. Please send 075G0003 and the quantity to receive a quotation, and confirm the connector and thread against your drawings.

Because this code is an OEM item, the quantity and the harness style matter as much as the sensor itself. Production lines normally order in boxes, and the data sheet lists a pack code beside the single-unit code, so tell us whether you need a single sample for validation or a production quantity. Keep the connector colour and the focus temperature range in your approved parts list to avoid mixing variants.

Before you order 075G0003, compare it with the nameplate of the unit you intend to replace. Photographs of the nameplate help us to confirm the exact code quickly, and we will tell you plainly if a different version of the same family looks like a better fit for your duty.

How the transmitter is used in refrigeration and HVAC control

In chillers, heat pumps and VRF systems the pressure on the suction or discharge side of the refrigerant circuit is one of the main inputs to the controller. A transmitter such as the DST P110 gives the controller a continuous analogue signal it can use to modulate a variable-speed compressor, manage expansion valve control or protect the system when pressure moves outside the expected window. In data centre cooling, where equipment runs continuously and capacity is staged closely to the heat load, a fast and stable pressure signal helps the control logic respond to changes without hunting. In transport and commercial refrigeration the same signal supports defrost decisions and condenser control across a wide range of operating states.

Because the media interface is welded stainless steel and compatible with all refrigerants, the same family can be designed into equipment that uses different refrigerants without changing the sensing principle. The MEMS element and the microcontroller-based diagnostics are what allow the transmitter to report a fault level distinctly from a valid measurement, which the controller software should be written to recognise.

Design-in considerations for OEM equipment

When an OEM selects a transmitter for a new platform, the range should sit comfortably above the highest normal operating pressure of the circuit point being measured while still giving useful resolution at the lower end. The 4 to 20 mA output is well suited to longer cable runs inside a unit and to electrically noisy environments around compressors and inverters, since a current signal is less sensitive to voltage drop than a voltage signal. Engineers should also consider where the transmitter is mounted: hanging it from a copper line is common, so the low weight helps, but the line itself should be supported so vibration from the compressor is not transmitted directly to the sensor body.

Controller input configuration needs to match the transmitter, including the scaling of the range and the handling of the fault signal level. Validating a sample unit on the actual equipment before release to production is good practice, particularly when moving from another sensor type with a different connector or thread.

Operating conditions in Oman and the GCC

Cooling equipment in Oman and the wider GCC works hard for much of the year, with high ambient temperatures, dust and humidity near the coast. Condensing units on rooftops and outdoor plant areas are exposed to direct sun and washdown, which is where the sealed connector and the IP69K enclosure rating are relevant. Installers should route the harness so that water drains away from the connector and so the cable is not trapped against hot refrigerant lines or sharp edges. For transport refrigeration operating between cities and harbours, a sealed automotive-style connection suits the shock and vibration of vehicle-mounted units. Recording the exact code, connector colour and focus temperature range against each equipment model keeps service teams from fitting the wrong variant during maintenance.

Documents and quotation

We attach the Danfoss DST P110 data sheet AI569728714486 as published. See other transmitters in pressure instrumentation.

Datasheets & Documents
  • PDF Datasheet Danfoss DST P110 pressure transmitter data sheet AI569728714486 (manufacturer, unaltered) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

Frequently Asked Questions

What is Danfoss 075G0003?
A DST P110 pressure transmitter with a 0 to 10 bar sealed gauge range, 4 to 20 mA output, 7/16-20 UNF female flare port and IP69K Metri-Pack connector.
Which refrigerants can it be used with?
The data sheet states that the welded stainless-steel interface is compatible with all refrigerants.
What does the 21.5 mA fault level mean?
The transmitter drives its output to 21.5 mA to report an internal fault, so a controller can alarm instead of using a false reading.
Is a mating connector included?
Cable accessories are listed separately in the data sheet; confirm the harness requirement with us.
Which document is included?
The Danfoss DST P110 data sheet AI569728714486, unaltered.