Brand: Danfoss
Danfoss 017-523866 RT 200 Pressure Switch 0.2-6 bar
Description
RT 200: a 0.2 to 6 bar industrial pressure switch with a latching maximum-pressure trip
Danfoss 017-523866 is an RT 200 from the RT industrial and marine series. It is built for the plant that needs a straightforward, repeatable pressure trip: a single bellows moves an SPDT snap contact, and in this version the contact stays tripped after the pressure has risen above the set value until someone resets it by hand. That latching behaviour is what makes the code useful as a safety cut-out for compressed air, lubrication or water circuits, where a restart should only follow an inspection.
The range of 0.2 to 6 bar and the fixed differential of 0.25 bar are deliberately narrow, so the trip point stays close to the scale value. The data sheet lists the RT series with high accuracy and repeatability, a long operating life and all major marine approvals, and it quotes a SIL 2 capability according to IEC 61508 for the series.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 017-523866 |
| Type | RT200 |
| Function | Pressure switch, manual reset at maximum pressure |
| Regulating range | 0.2 to 6 bar |
| Differential (fixed) | 0.25 bar |
| Contact system | SPDT |
| Contact rating | AC15=3 A, 400 V; AC1=10 A, 400 V; AC3=4 A, 400 V; DC13=12 W, 220 V; LR=28 A, 400 V |
| Enclosure | IP54 |
| Pressure connection | G 3/8 male, ISO 228-1 |
| Max. working pressure (PS) | 22 bar |
| Max. test pressure (Pe) | 25 bar |
| Pressure element | Bellows |
| Ambient temperature | -50 to 70 C |
| Cable entry | 2 x Pg 13.5, screwed |
| Approvals as listed | BV; CCC; CE; DNV; EAC; GL; KR; LR; LVD; NKK; RINA; RoHS; RoHS China; TYSK; UA |
| Net weight | 0.864 kg |
| EAN | 5702423120925 |
How the RT 200 is used on machinery and pump skids
Typical duty is the high-pressure limiter on a small compressor, a lube-oil pressure alarm and a pump discharge trip. With a PS of 22 bar and a 25 bar test pressure the housing leaves generous overpressure margin over the 6 bar range limit, so surges in the line do not damage the bellows. Because the differential is fixed at 0.25 bar there is only one spindle to set, which reduces commissioning error.
A sibling, the RT 200L, adds an adjustable neutral zone for floating control with a variable-speed pump, and the same family includes versions with automatic reset; those carry other code numbers. If you are replacing an installed unit, read the type and code from its nameplate and compare with 017-523866 before ordering.
Mounting and electrical connection
The G 3/8 male thread should be sealed with the flat washer or a suitable compound, and the housing is held on its mounting lugs rather than by the pressure pipe. Wiring enters through the 2 x Pg 13.5 screwed entries; keep conductors within the ranges printed in the installation guide for RT 5, RT 110, RT 112, RT 116, RT 117, RT 121 and RT 200.
The contact rating shown above is for the AC15 and AC1 duties of the SPDT system, so use an auxiliary relay or contactor for larger loads. Seven Star LLC is an independent supplier in Muscat; send this code with the setting and the voltage and we will confirm supply.
Selection checks before choosing 017-523866
Start with the pressure at which the circuit must trip and make sure it sits comfortably inside the 0.2 to 6 bar range rather than at either end. Confirm that a manual reset is really what the process needs: it suits safety cut-outs where an operator should inspect the system before restart, but not control duties that must reset on their own. Check the maximum pressure the line can reach during surges or blocked-valve conditions against the PS value, and compare the load to be switched with the contact ratings in the table. Finally, consider whether the IP54 enclosure is enough for the location or whether the switch should be placed in a sheltered position.
Setting and commissioning the trip point
Set the scale to the required trip value following the Danfoss instructions, then confirm the real trip pressure with a calibrated test gauge or pressure source rather than relying on the scale alone. Raise the pressure slowly, note the value at which the contact changes over, and adjust if necessary. After the trip, reduce the pressure, reset the switch by hand and check that the controlled circuit restarts only when intended. Record the final setting and the test result in the commissioning file, and protect the setting against unauthorised change where site rules require it.
Installation in Oman’s heat, dust and humidity
Pump skids, compressor rooms and water plants in Oman are often hot, dusty and, near the coast, humid and salty. Mount the switch where it is shaded from direct sun and protected from water spray and wash-down, with the cable entries facing downward where practical so water does not run into them. Use glands that suit the cable and keep them tight to hold the IP54 rating. Where pressure pulsations from pumps or compressors are strong, review the Danfoss documentation and the pipework layout so that the bellows and contact are not stressed by constant fluctuation, and keep the pressure line short and supported.
Periodic testing and maintenance
A safety cut-out that never trips in normal service can only be trusted if it is tested. Include the switch in the periodic function-test schedule: raise the pressure to the set value, confirm that it trips and resets correctly, and record the actual trip pressure. Inspect the housing, cable entries and pressure connection for corrosion, leaks or damage, and replace a unit that no longer trips at its setting.
Spare units and replacement planning
Because this switch protects equipment and people, a failed unit should be replaced with the same code number rather than with whatever pressure switch is at hand. Keep the code, range, setting and reset type in the maintenance system, and confirm them against the nameplate when ordering a replacement.
Documents and quotation
The attached file is the Danfoss RT industrial pressure switch data sheet AI555514425055, including the type tables, contact system diagrams and dimensions. See also our pressure instrumentation category, and request a quotation for 017-523866 with the quantity you need.
Datasheets & Documents
- Datasheet Danfoss RT pressure switch (industrial) data sheet AI555514425055 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
An RT 200 pressure switch: 0.2 to 6 bar range, fixed 0.25 bar differential, SPDT contact, G 3/8 male connection, IP54, manual reset at maximum pressure.
In this version the contact latches after the maximum pressure trip and stays open until it is reset by hand, which supports a safety cut-out function.
Danfoss lists a 22 bar maximum working pressure and a 25 bar test pressure for this code.
No. The differential is fixed at 0.25 bar for this code. The RT 200L variant has a neutral zone setting and is a different code number.
The Danfoss RT industrial pressure switch data sheet AI555514425055, unchanged. Confirm setting and electrical load with us before ordering.