Brand: Danfoss
Danfoss 130B1235 VLT PROFINET MCA 120 Option Card, coated
Description
A PROFINET option card for VLT drives with built-in two-port switch
The 130B1235 is the conformal-coated version of the Danfoss VLT PROFINET MCA 120, a fieldbus option for VLT drives; the uncoated version carries code number 130B1135. According to the Danfoss installation guide the interface communicates with any system that complies with the PROFINET schema versions 2.2 and 2.3, and it is intended for use with the VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive FC 301/FC 302 and VLT Decentral Drive FCD 302. The card has two Ethernet ports with a switch inside, which allows star, line and ring topologies without an external switch for every drive.
Technical specifications
| Parameter | Specification |
|---|---|
| Order number | 130B1235 (conformal coated); uncoated version 130B1135 |
| Product | VLT PROFINET MCA 120, option A (fieldbus) card |
| Compatible drives | FC 102, FC 103, FC 202, FC 301/FC 302, FCD 302 |
| Protocol | PROFINET, schema versions 2.2 and 2.3 |
| Ethernet ports | 2 (Ethernet port 1 and port 2, internal switch) |
| Topologies | Star, line, ring/redundant line (needs a redundancy manager switch) |
| Address setting | 8 DIP switches, 253 station names (host name 12-08), or via parameter or DCP |
| Cable | Shielded CAT5e/CAT6e recommended; maximum 100 m between switches |
| Status LEDs | Three bicolor LEDs: MS, NS1, NS2 |
| Design rule | Do not connect more than 32 drives in a series |
| Danfoss store data | Net weight 0.405 kg, gross weight 0.5 kg, volume 4.095 dm3, EAN 5710107611539; classed as a recommended and self-service spare part |
Choosing between 130B1135 and 130B1235
| Code part | Meaning |
|---|---|
| 130B1135 | MCA 120, uncoated version |
| 130B1235 | MCA 120, conformal-coated version (this item) |
| Option slot | Option A; the card ships with an LCP cradle, front covers, stickers and accessory bags when not factory mounted |
Topology, timing and commissioning notes
The installation guide gives minimum update times for line topologies: 2 ms for fewer than 8 drives in series, 4 ms for 8-16, 8 ms for 16-32 and 16 ms for 33-50 drives, and more than 50 not recommended; the design rules also say not to connect more than 32 drives in a series. In a line topology all drives must be powered, either by mains or by a 24 V DC option card, for the built-in switch to work, and the drive with the longest discharge time should be mounted first. Ring topology requires a redundancy manager and an external switch that supports loss-of-line detection; the transition from ring to two lines can take from 200 ms to several seconds.
Warning 34 indicates a fieldbus fault. The official Danfoss photo of this part shows the uncoated 130B1135 label, so we leave this listing without a picture to avoid a conflicting model number. Confirm the drive type and software version before ordering.
Documents and quotation
The manufacturer installation guide is attached as a download. Compatible drives on our site include the Danfoss VLT AutomationDrive FC 302, the Danfoss VLT HVAC Drive FC 102 and the Danfoss VLT AQUA Drive FC 202; see also AC drives. Send us the drive type code and confirm the option code with us before ordering.
How the 130B1235 PROFINET option works
The MCA 120 is mounted in the option A slot of the drive and connects the VLT drive to a PROFINET IO controller, typically a PLC. Cyclic process data such as control word, speed reference, status word and actual speed are exchanged at the configured update time, while parameters can be read and written acyclically. Once the option is powered up, the drive shows the additional parameter groups 9-** and 12-** for fieldbus and Ethernet settings.
The built-in Ethernet switch with two equal RJ45 ports is what makes line wiring possible: the cable runs from the PLC or switch to the first drive and onwards from drive to drive. Danfoss also supports star topology and ring/redundant line topology; ring operation requires an external switch acting as redundancy manager.
130B1235 technical data from the installation guide
| Item | Value |
|---|---|
| Minimum update time, line, fewer than 8 drives | 2 ms |
| Minimum update time, 8–16 drives | 4 ms |
| Minimum update time, 16–32 drives | 8 ms |
| Minimum update time, 33–50 drives | 16 ms (more than 50 not recommended) |
| Station name by address switches | 253 names; all switches ON = name from parameter 12-08 Host Name or DCP |
| Cable | CAT5e/CAT6e, shielded recommended; PROFINET cable type A, B or C |
| Max. length between switches | 100 m (use fibre for longer distances) |
| Separation from power and motor cables | ≥200 mm (500 mm above 315 kW); cross at 90° |
| Port orientation | Ethernet port up for A1–A3, down for A4–A5 and B–E enclosures |
130B1235 selection & ordering guide
- Coated or uncoated. 130B1235 is the conformal-coated version; 130B1135 is uncoated. Coated boards are the usual choice for humid, dusty or corrosive atmospheres.
- Drive compatibility. The option is for FC 102, FC 103, FC 202, FC 301/302 and FCD 302. Give us the drive type code from the nameplate.
- Retrofit kit. When the option is not factory-mounted, the delivery includes the LCP cradle, front covers, stickers, accessory bags, strain relief for A1/A2 and the installation guide.
- Power for line topology. All drives in a line must be powered, from mains or a 24 V DC option, for the switch to pass traffic; plan a 24 V DC backup if drives are isolated during maintenance.
Installation & maintenance
Isolate the drive and wait for the discharge time before fitting the option. Set the address switches before power-up, because a changed station name takes effect only at the next power-up. Use shielded cable, keep the specified separation from motor and power cables, and do not connect more than 32 drives in series.
For diagnostics, the option has three bicolour LEDs: MS, NS1 and NS2. In normal operation MS and at least one NS LED are steady green. The wink function from the engineering tool makes all three flash yellow so the correct drive can be located in the panel. Warning 34 Fieldbus Fault appears if there is no communication with the master within 60 s after power-up, if the master is in stop mode, or if the configuration is wrong.
Typical applications in Oman & the GCC
- HVAC fans and chilled-water pumps on FC 102 drives in commercial buildings and district cooling plants.
- Water and wastewater pumping on FC 202 drives integrated into PROFINET-based SCADA.
- Process lines and material handling on FC 301/302 drives in industrial plants.
The conformal-coated 130B1235 is a sensible choice for coastal and humid sites.
Why source the 130B1235 from Seven Star LLC
Seven Star LLC supplies Danfoss VLT options across Oman and the GCC. Request a quote with the drive type code and quantity, and our team can help confirm the correct ordering code.
Datasheets & Documents
- Installation Guide Danfoss VLT PROFINET MCA 120 Installation Guide AN319149671399 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
130B1235 is the conformal-coated MCA 120; 130B1135 is the uncoated version.
FC 102, FC 103, FC 202, FC 301/FC 302 and the decentral FCD 302.
Two, with an internal switch.
Shielded CAT5e or CAT6e, with 100 m maximum between switches.
By the eight address switches or by parameter 12-08 Host Name or a DCP command.