Brand:

Murphy Tattletale Annunciators and Magnetic Switches for Engine and Motor Shutdown

Description

Latching trip devices that act on Swichgage and switch signals

The Murphy Tattletale annunciators and magnetic switches translate Swichgage contact operations into decisions and operate the alarm or shutdown device. They are the electrical load-carrying devices for the alarm or shutdown circuit. The difference between the two types is that a Tattletale annunciator shows which monitored function failed, while a magnetic switch does not. Magnetic switches work basically as a latching relay.

They are used with engines or electric motors. On battery-coil ignition engines the switch opens the ignition coil circuit to shut down; on magneto or capacitor discharge ignitions it grounds the ignition output; some models can trip fuel valves as well. Diesel engines are stopped by closing the fuel or air supply, and for electric motors various models operate the motor starter or holding coil directly or with a Murphy transformer-relay assembly.

Technical specifications

The bulletin covers a family of models. The table lists the base models and their descriptions as printed.

Parameter Specification
117 / 117PH Shuts down 12 to 32 V battery-coil ignition or diesel engines; breaks circuit when tripped; disconnects from battery after trip; contacts 10 A at 32 VDC; 14 A fuse
MS2100 Multipurpose Tattletale with dry contacts; makes two circuits and breaks another; operates from 120 VAC or capacitor discharge ignition; replaces 100PH, 307CD, 307PHCD and 224CD
MS2110 Same contact scheme; operates from 12 or 24 VDC or 24 VAC; replaces 221PH, 169PH, 274 and 274PH
MS2120 Same contact scheme; operates from magneto ignition; replaces 307, 307PH and 224
518PH / 518APH / 518E Swichgage and N.C. contacts wired closed loop (in series); specify 12 or 24 VDC; contacts 10 A at 24 V; 14 A fuse. The 518E is for high vibration, 12 V only
520APH As 518PH with a 30 second delay on one Swichgage input and immediate trip on the second; delays 5 to 120 s available
521PH Grounds magneto or CD ignition when N.C. contacts open; specify 12 or 24 VDC; contacts 10 A at 24 V
760A / 760AF / 761APH Time delay lockout of Swichgage contacts on start-up; delays 15, 30 (standard) or 60 s; 760A resets automatically, 761APH has manual reset; contacts 10 A at 24 V; 14 A fuse; 760A and 761APH carry the CE mark
M4264 series Detects loss of magneto or CD ignition output and transfers contacts; contacts 10 A, 48 VAC/VDC; M42641CS transfers SPDT dry contacts
R129A SPDT relay with 10 A dry contacts; specify 12 or 24 VDC; 14 A fuse

How the family is organized

Models are electrically tripped relay-type devices. Versions exist for battery power, 120 VAC, conventional magnetos and capacitor discharge ignitions. Energized-to-run models allow closed-loop circuitry, while others draw momentary power to trip. All models have a weather-resistant case with screw terminals. Manually reset models have a face-mounted reset push button that also serves as the fault indicator on the Tattletale version, so only the unit connected to the failed function pops out.

Electrically reset models perform the same functions and are reset by cycling the supply off and on. Time delay models use solid state timing to lock out contacts for start-up, to allow alarms before shutdown, or to apply power to a shutdown circuit and disconnect it after a set time.

Selecting and protecting a unit

Match the model to the power source and ignition type, the contact action needed (make, break or both), the reset type and the delay. For example, the 760A family is for battery-coil ignition or diesel with start-up lockout, while the MS2120 suits magneto ignition. Option codes cover an auxiliary SPDT switch, an environmentally sealed version and an explosion-proof less case version where applicable, and not every combination is available.

The bulletin warns to always provide proper circuit protection with fuses or circuit breakers, and notes that the 760A cannot be adequately protected by a circuit breaker in a dead short with a battery source, so fuses are the preferred protection. Enovation Controls lists this product family on its Legacy Products page, which describes those items as less popular or outdated but still available for purchase. Confirm current availability and any replacement part before ordering.

How the Murphy Tattletale works

A Swichgage contact opens or closes when a monitored value goes out of limits. The Tattletale or the magnetic switch picks up the signal and latches. It then trips the shutdown device or sounds the alarm.

Where the Tattletale is used

  • Diesel engines
  • Gasoline engines
  • Electric motors
  • Generator sets
  • Pump drives

Selection checklist for the Tattletale

  • Engine or motor type
  • Ignition system
  • Supply voltage
  • Annunciator or switch type
  • Time delay need
  • Reset method
  • Contact arrangement
  • Vibration level

Installation, commissioning and maintenance notes for the Tattletale

Mount the unit in a dry place and wire the Swichgage contacts to it. Connect the shutdown circuit and test the trip by opening a contact. Check the wiring and the reset action at regular intervals.

Requesting a quotation for the Murphy Tattletale

Please send the engine or motor type, the voltage and the model needed. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

Tattletale device type

It is a latching annunciator or magnetic switch.

Tattletale maker

It is made by Murphy.

Tattletale role

It carries the load for the alarm or shutdown circuit.

Tattletale input

It acts on Swichgage and switch signals.

Tattletale annunciator

The annunciator shows which monitored function failed.

Tattletale magnetic switch

The magnetic switch does not show the failed function.

Tattletale latching

A magnetic switch works like a latching relay.

Tattletale coil ignition

On battery-coil ignition the switch opens the ignition coil circuit.

Tattletale magneto ignition

On magneto ignition the switch grounds the ignition output.

Tattletale fuel valves

Some models can trip fuel valves.

Tattletale diesel engines

Diesel engines are stopped by closing the fuel or air supply.

Tattletale electric motors

Some models operate the motor starter or holding coil.

Tattletale model 117

The 117 shuts down 12 to 32 V battery-coil ignition or diesel engines.

Tattletale model MS2100

The MS2100 operates from 120 VAC or capacitor discharge ignition.

Tattletale model MS2110

The MS2110 operates from 12 or 24 VDC or 24 VAC.

Tattletale model MS2120

The MS2120 operates from magneto ignition.

Tattletale dry contacts

The MS2100 series has dry contacts that make two circuits and break another.

Tattletale model 518PH

The 518PH wires the Swichgage contacts in a closed loop.

Tattletale vibration model

The 518E is for high vibration and runs on 12 V only.

Tattletale model 520APH

The 520APH has a 30 second delay on one Swichgage input.

Tattletale delay range

Delays from 5 to 120 seconds are available.

Tattletale model 521PH

The 521PH grounds a magneto or capacitor discharge ignition.

Tattletale lockout

The 760A series gives a time delay lockout at start-up.

Tattletale lockout times

Delays are 15, 30 or 60 seconds.

Tattletale reset

The 760A resets automatically and the 761APH has a manual reset.

Trip records for the Tattletale

Record the trip cause, the reset time and the date of each event.

Choosing the right Tattletale model

Choose the model from the ignition type and the supply voltage.

Documents and quotation

The attached bulletin 78793 (revision 2014/09/27) is the source for the table. Seven Star LLC supplies Murphy products as an independent supplier in Muscat. Send the exact model, voltage, delay time and options with your enquiry. Browse controllers and data acquisition for related products.

Datasheets & Documents
  • PDF Datasheet Murphy Tattletale annunciators and magnetic switches bulletin 78793 (rev. 2014/09/27) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Murphy is the engine and equipment instrumentation brand of Enovation Controls, LLC, headquartered in Tulsa, Oklahoma, USA. Enovation Controls operates as a stand-alone subsidiary of Helios Technologies, and the Murphy name goes back to 1939, when Frank W. "Pat" Murphy formed FW Murphy Manufacturing around a safety switch for engine protection. Seven Star LLC is an independent supplier in Muscat and lists selected Murphy products for engines, generator sets and pumps.

Murphy product groups

The classic Murphy range includes Swichgage and Murphygage pressure and temperature gauges, level switches, magnetic pickups, vibration switches, Tattletale annunciators and Sentinel battery chargers. Newer Murphy products include PowerCore controllers and PowerView displays with CAN J1939 communication. Enovation Controls lists many classic Murphy items on its Legacy Products page, which describes them as still available for purchase.

Ordering Murphy parts: what we need

Send the full model code, range or scale, thread, voltage and any options. Because many Murphy parts are legacy designs, we check the configuration and current availability against Enovation Controls documents before quoting.

Frequently Asked Questions

What is the difference between a Tattletale and a magnetic switch?
A Tattletale annunciator indicates which monitored function failed. A magnetic switch trips the circuit but does not indicate the cause.
What ignition systems does the family support?
Battery-coil ignition, magneto, capacitor discharge and diesel engines, plus electric motor starters, depending on the model.
Which model has start-up lockout?
The 760A, 760AF and 761APH lock out Swichgage contacts on start-up, with 15, 30 (standard) or 60 second delays.
Is circuit protection needed?
Yes. The bulletin advises fuses or circuit breakers and notes that fuses are preferred for the 760A.
Is this a legacy product?
Enovation Controls lists Tattletale annunciators and magnetic switches on its Legacy Products page as still available for purchase.