- Automation & ControlView all 3,067 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Festo
Festo VPEV-1/8 Pressure Switch
Description
Festo VPEV-1/8 vacuum switch: overview
The Festo VPEV-1/8 (part number 150261) is an adjustable pneumatic-electric vacuum switch with a mechanical changeover contact. Festo specifies a measuring and operating range of −1 to +1.6 bar relative pressure. As delivered, the switching threshold is set in the vacuum range of −0.95 to −0.2 bar. After the conversion described by Festo, the same unit can switch on positive pressure between 0.16 and 1.6 bar. A G1/8 pneumatic port, a DIN 43650 type A plug connection and a yellow switching-status LED make it a compact, self-contained unit for confirming vacuum or pressure in pneumatic circuits.
Key features
- Vacuum or pressure switching: threshold −0.95 to −0.2 bar as standard, 0.16 to 1.6 bar after conversion.
- Changeover contact: silver contacts switching up to 250 V AC or 125 V DC, with a maximum output current of 5000 mA.
- Industrial plug connection: square type A plug to DIN 43650.
- Visual status: yellow LED shows the switching state.
- Robust housing: wrought aluminium alloy, IP65, corrosion resistance class CRC 2.
- Explosion protection: Festo lists ATEX zones 1, 2, 21 and 22, subject to the information in the certificate.
Technical specifications of the Festo VPEV-1/8
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Festo / 150261 |
| Type | VPEV-1/8 vacuum switch |
| Measured variable / method | Relative pressure / pneumatic-electric pressure transducer |
| Measuring and operating range | −1 to 1.6 bar (−0.1 to 0.16 MPa; −14.5 to 23.2 psi) |
| Threshold setting range | −0.95 to −0.2 bar |
| Threshold setting range after conversion | 0.16 to 1.6 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4]; lubricated operation possible (then always required) |
| Medium and ambient temperature | −20 to +80 °C |
| Switching element | Changeover; silver contacts |
| Max. switching frequency | 3 Hz |
| Max. switching voltage | 250 V AC; 125 V DC |
| Max. output current | 5000 mA |
| Min. load current | 1 mA at 24 V; 10 mA at 10 V; 100 mA at 5 V |
| Utilisation categories | Inductive AC-14, DC-13; resistive AC-12, DC-12 |
| Electrical connection | Plug type A to DIN 43650, square design |
| Pneumatic connection | G1/8 |
| Mounting / position | Through-hole / any |
| Status indication | Yellow LED |
| Degree of protection | IP65 |
| Housing material | Wrought aluminium alloy |
| Product weight | 240 g |
| Standards and approvals | EN 60947-5-1; CCC; CE (Low Voltage Directive); UKCA; RoHS; LABS (PWIS) conformity VDMA24364-B1/B2-L |
Operating principle
Festo classifies the VPEV as a pneumatic-electric pressure transducer. The relative pressure at the G1/8 port acts on a mechanical sensing element. When the pressure passes the threshold set on the adjuster, that element operates the changeover contact, so one circuit opens and the other closes. No separate power supply is needed for sensing, and the contact can switch a load directly. The datasheet still specifies minimum load currents (1 mA at 24 V, rising to 100 mA at 5 V), because silver contacts need some current to stay reliable. For very low-level PLC inputs, check that the input draws enough current at its voltage.
Typical applications
- Confirming that a vacuum suction cup or gripper has picked up a part before the handling axis moves.
- Monitoring vacuum generators and vacuum supply lines for loss of vacuum.
- After conversion, monitoring low positive pressures up to 1.6 bar in compressed-air circuits.
- Applications needing a directly switched AC or DC load without an electronic sensor.
- Installations in ATEX zones, where the certificate conditions are met.
Selection and compatibility notes
The Festo VPEV-1/8 suits compressed air and vacuum air to the stated ISO 8573-1 class. If the circuit has been run with lubricated air, Festo notes that lubricated operation must then continue. For switching duty, select the contact load from the utilisation category, not from the maximum voltage and current alone: AC-14 and DC-13 apply to inductive loads such as small solenoids and relays, and AC-12 and DC-12 to resistive loads. The maximum switching frequency of 3 Hz limits the switch to monitoring rather than fast cycling. Where an installation needs an analogue signal, a display or a much higher switching rate, an electronic pressure sensor is the better choice.
Installation and commissioning
- Isolate the electrical supply and vent the pneumatic line before installation.
- Mount the switch using its through-holes; any mounting position is permitted.
- Connect the vacuum or pressure line to the G1/8 port with a suitable fitting, keeping the line short for a quick response.
- Wire the DIN 43650 type A plug according to the required contact function (normally open or normally closed path), and fit the plug seal so that IP65 is achieved.
- Set the threshold with the adjuster, then cycle the vacuum and watch the yellow LED to confirm switching at the required point.
- For positive-pressure use, carry out the conversion exactly as described in the Festo operating instructions before setting the 0.16–1.6 bar threshold.
Maintenance and troubleshooting
Check the switch periodically by cycling the vacuum and confirming that the LED and the controller input change state at the expected point. If the switch never operates, look for leaks in the sensing line, a blocked port or a threshold set beyond the vacuum the generator can actually reach. Erratic switching on low-current PLC inputs can come from load currents below the stated minimum. Contacts that have switched heavy inductive loads without suppression may wear; fit suitable suppression on the load. Contaminated or wet air can affect the sensing element, so keep air quality within the stated class.
Quotation enquiries for Oman and the GCC
Seven Star LLC supplies the Festo VPEV-1/8 on request to customers in Oman and across the GCC. To prepare your quotation, please send:
- The exact type and part number (VPEV-1/8, 150261).
- The quantity needed.
- A photo of the nameplate for replacement units.
- The application, including vacuum or pressure duty, switching point and the load to be switched.
Availability, condition and lead time are confirmed at quotation. We offer technical support with selection and cross-checking of the reference against Festo documentation.
Datasheets & Documents
- Datasheet VPEV-1/8 / 150261 Manufacturer Datasheet — Spanish Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Festo is a German maker of pneumatic and electric automation technology, founded in 1925 in Esslingen am Neckar by Albert Fezer and Gottlieb Stoll; the name comes from their surnames. It first made woodworking machines and power tools before moving into pneumatics in the 1950s. Festo is family-owned and still headquartered in Esslingen.
Seven Star LLC sources and supplies Festo cylinders, valves and valve terminals for machine maintenance and projects in Oman and the GCC.
Festo company profile
| Founded | 1925, Esslingen am Neckar, Germany |
|---|---|
| Founders | Albert Fezer and Gottlieb Stoll |
| Name | From FEzer and STOll |
| Headquarters | Esslingen am Neckar |
| Ownership | Family-owned |
| Product families | DSBC and ADN pneumatic cylinders, VUVG and VTUG solenoid valves and valve terminals, MS series air preparation units, CPX-AP remote I/O, EMMT servo motors and CMMT servo drives, electric axes and grippers |
Milestones
- 1925: Fezer and Stoll found the company in Esslingen.
- 1950s: Festo begins making pneumatic components.
Festo products listed
Two items show the two halves of a pneumatic circuit. The VTUG is a valve terminal: a manifold that carries a row of directional valves with common air supply and a shared electrical connection. The DSBC-32-100-PPVA-N3 is an ISO standard cylinder. Its type code reads as 32 mm piston diameter and 100 mm stroke, with adjustable end-position cushioning and a piston magnet for position sensing.
Festo products we list
Ordering Festo parts: what we need
Festo parts carry both a type code and a numeric part number on the label. Send both when you can; the part number is the shortest route to an exact match. For a cylinder give the full type code as on the listed DSBC example, plus mounting parts and proximity switches if required. For a VTUG valve terminal send the configuration code or a label photo: number of valve positions, valve functions, coil voltage and the electrical connection type all vary from one terminal to the next.
Facts checked against Festo's corporate history pages, October 2026.
Browse Festo products by category: Solenoid Valve, Valve Actuator.
FAQ
Questions about the Festo VPEV-1/8 Pressure Switch
Answers from our engineering team on installation, compatibility and integration.
01What is the setting range of the Festo VPEV-1/8?
The threshold can be set from -0.95 to -0.2 bar. After the conversion described by Festo, it can switch on positive pressure from 0.16 to 1.6 bar.
02What type of contact does it have?
A changeover contact with silver contacts, rated up to 250 V AC or 125 V DC and a maximum output current of 5000 mA.
03Is there a minimum load current?
Yes. Festo specifies a minimum of 1 mA at 24 V, 10 mA at 10 V and 100 mA at 5 V.
04What are the pneumatic and electrical connections?
The pneumatic port is G1/8 and the electrical connection is a square type A plug to DIN 43650.
05Does it show its switching state?
Yes. A yellow LED indicates the switching status.


















Reviews