Brand: Beamex
Beamex MC2 Hand-Held Process Calibrator
Description
Overview
Beamex MC2 is a compact, lightweight hand-held calibrator that gathers the everyday calibration tasks of an instrument technician into one rugged device. It has a graphical backlit display, a menu-based multilingual interface and a full numeric keyboard, and it carries the same quality standards as the larger Beamex calibrators. The Beamex MC2 measures and generates voltage, current, frequency and pulses, measures and simulates resistance, RTD and thermocouple signals, and measures pressure through an internal module or external pressure modules.
Seven Star LLC supplies the Beamex MC2 on request to maintenance, instrumentation and quality teams in Oman and the GCC, with engineering support in Muscat. It is a practical entry point for a calibration programme: technicians who need a lighter instrument than the Beamex MC6 advanced field calibrator and communicator can carry the MC2 on routine loop checks and transmitter verification rounds, while the MC6 stays with complex jobs.
Measure and Source Principle
The Beamex MC2 works by measuring a signal from an instrument under test and comparing it with the known value it is generating, or by generating a precise signal and observing how a transmitter or indicator responds. For a pressure transmitter, the technician applies pressure, the internal or external pressure module measures it, and the MC2 supplies loop power at 24 V with a HART-compatible 300 ohm output impedance while measuring the 4 to 20 mA output current. The calibrator then shows the error as a percentage or in engineering units so that the technician can adjust the instrument if needed.
For temperature loops the MC2 simulates an RTD or thermocouple to test a transmitter input, or measures a probe directly to verify a sensor. The error display can be shown in the input or output unit, and values can be scaled into custom units. Since firmware version 3.20 released in March 2019, the MC2-MF and MC2-TE models with serial numbers above 13000 are documenting calibrators. They save results in internal memory and exchange them with Beamex CMX and LOGiCAL calibration software, so calibration data moves into the maintenance system without manual typing.
Engineering Design of the Beamex MC2
The Beamex MC2 weighs 720 to 830 g and measures 215 x 102 x 49 mm, with a 60 x 60 mm, 160 x 160 pixel backlit LCD. Impact protectors and a membrane keyboard make it robust enough for plant use, and the operating range is −10 to +50 °C at up to 80 percent relative humidity without condensation. A rechargeable NiMH pack of 4000 mAh provides 13 to 24 hours in measurement mode with the backlight off, or 8 to 12 hours when sourcing an average of 12 mA into a loop, and charging takes about five hours.
Pressure capability is flexible. The MC2 can hold one internal pressure module, from IPM200mC (±200 mbar) through IPM2C, IPM20C and up to IPM160 (0 to 160 bar), together with a barometric option for absolute measurement. External EXT pressure modules extend the range from 10 mbar differential up to 1000 bar, and all EXT modules are also compatible with the Beamex MC4, MC5 and MC6. The device is delivered with a traceable, accredited calibration certificate and a two-year standard warranty with one year on the battery.
Key Features
The Beamex MC2 packs a wide measurement range into a small enclosure:
- Compact, lightweight housing under one kilogram is comfortable to carry on long calibration rounds and to hold in one hand at the instrument.
- Voltage measurement from −1 to 60 V and current measurement to ±100 mA, with one-year uncertainty of 0.02 % of reading plus a small offset.
- Internal HART-compatible 24 V loop supply with 300 ohm impedance allows transmitter testing without an external power source or resistor.
- Frequency measurement from 0.0027 Hz to 50 kHz, pulse counting to 9,999,999 pulses and switch sensing cover flow, speed and limit-switch checks.
- RTD and thermocouple measurement and simulation allow temperature transmitters and sensors to be verified with one device.
- Internal pressure module plus connection for external modules offers configurable pressure ranges, with units covering more than thirty options.
- Documenting calibrator function for MC2-MF and MC2-TE models supports a paperless flow with Beamex calibration software.
- Traceable, accredited calibration certificate delivered as standard gives each instrument documented accuracy from day one.
Industrial Applications
The Beamex MC2 fits the routine work of instrument technicians in oil and gas, power, water and general industry: verifying 4 to 20 mA transmitters, checking temperature transmitters with simulated RTD or thermocouple inputs, testing pressure switches, confirming flow signals by frequency or pulse count, and tracing loop faults with the built-in loop supply. Because it is a safe-area instrument, it suits workshops, control rooms, utility plants and non-classified process areas.
In Oman, Seven Star LLC supports calibration teams at desalination plants, utilities, food and beverage facilities and industrial estates in Muscat, Sohar and Salalah with MC2 supply and accessory guidance, including test leads, pressure hoses and external modules. Where a team also calibrates temperature elements, the MC2 pairs well with a dry block such as the Isotech Jupiter 4852 portable dry block calibrator, and for transmitters it can verify devices like the Rosemount 3144P temperature transmitter. Ask for the Beamex MC2 datasheet if you want to confirm module ranges and accuracy figures.
Technical Specifications
Selected specifications of the Beamex MC2 from the manufacturer brochure follow. Accuracy values are one-year uncertainties and depend on the selected module.
| Parameter | Specification |
|---|---|
| Model | Beamex MC2 hand-held process calibrator |
| Display | 60 x 60 mm, 160 x 160 pixel backlit LCD |
| Weight and size | 720–830 g; 215 x 102 x 49 mm |
| Battery | Rechargeable NiMH, 4000 mAh, 3.6 V; 5 hour charge time |
| Voltage measurement | −1 to 60 V DC; 0.02 % of reading + 5 µV (low range) |
| Current measurement | ±100 mA; 0.02 % of reading + 1.5 µA |
| Loop supply | 24 V ±10 %, above 25 mA, HART-compatible 300 Ω |
| Frequency | 0.0027 Hz to 50 kHz; 0.01 % of reading |
| Pressure | One internal module (200 mbar to 160 bar) plus external modules |
| Operating temperature | −10 to +50 °C |
| Max. input voltage | 30 V AC, 60 V DC |
| Warranty | 2 years; 1 year for battery pack |
Ordering Notes for the Beamex MC2
Pricing for the MC2 depends on the exact order code, quantity and delivery point in Oman or the GCC, so it is given in a written quotation rather than as a list price.
Request a Quote for Beamex MC2
To request a quotation for the Beamex MC2, tell Seven Star LLC which pressure range, accessories and calibration certificate you need. We supply the Beamex MC2 on request with engineering support in Muscat, and we can share the Beamex MC2 datasheet and help you compare it with the MC4 and MC6 for instrumentation and procurement teams across Oman and the GCC.
Datasheets & Documents
- Brochure Beamex MC2 Hand-Held Process Calibrator Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex MC2 Hand-Held Process Calibrator
Answers from our engineering team on installation, compatibility and integration.
01What can the Beamex MC2 calibrate?
The MC2 measures and generates voltage, current, frequency and pulses, measures and simulates resistance, RTD and thermocouple signals, and measures pressure with internal and external modules. That covers pressure, temperature and electrical instruments in one hand-held device.
02Is the Beamex MC2 a documenting calibrator?
Since firmware version 3.20 from March 2019, the MC2-MF and MC2-TE models with serial numbers above 13000 are documenting calibrators. They store results and communicate with Beamex CMX and LOGiCAL software. Confirm the model and serial range when ordering.
03Can it power a transmitter loop?
Yes. The MC2 includes an internal 24 V loop supply, rated above 25 mA and short-circuit protected, with a 300 ohm HART-compatible output impedance, so a two-wire transmitter can be powered and measured without extra equipment.
04How long does the battery last?
The NiMH battery lasts 13 to 24 hours in measurement mode with the backlight off, or 8 to 12 hours when sourcing an average of 12 mA with the backlight on. Charging takes about five hours.
05Does Seven Star LLC supply the Beamex MC2 in Oman?
Seven Star LLC supplies genuine Beamex MC2 calibrators to Oman and the GCC, with engineering support in Muscat. We provide quotations with pressure modules and accessories and can send the manufacturer documentation on request.