MEDC XB15 Explosion-Proof Xenon Beacon

Description

The MEDC XB15 beacon (now manufactured under the Eaton Crouse-Hinds MEDC brand) is a rugged explosion-proof Xenon beacon designed to deliver reliable visual alarm signaling in hazardous area installations across oil, gas and petrochemical facilities, onshore and offshore. Built around a high-intensity Xenon flashtube with a light output range of 5 to 21 Joules depending on configuration, the XB15 provides clear, attention-getting visual warning even in bright daylight or heavy fog conditions typical of process plants and marine environments.

Hazardous Area Certification

The XB15 is certified for use in Zone 1 and Zone 2 hazardous locations under ATEX and IECEx schemes, with UL-listed variants also available for North American installations. Its flameproof (Ex d) enclosure prevents an internal spark or arc from igniting a surrounding explosive atmosphere, making it suitable for installation in refineries, offshore platforms, chemical processing plants, and other facilities where flammable gases or vapors may be present.

Technical Specifications

Parameter Value
Manufacturer MEDC (Eaton Crouse-Hinds)
Model XB15
Product Type Explosion-proof Xenon beacon
Light Output 5 to 21 Joules depending on configuration
Certification ATEX and IECEx, Zone 1 and Zone 2; UL-listed variants available
Protection Concept Flameproof (Ex d)
Ingress Protection IP66/IP67
Enclosure GRP with stainless steel wire lens guard
Wiring Supervisory diode, four-wire lead connection
Lens Colors Red, amber, blue, green and clear

Rugged GRP Construction

Housed in a glass-reinforced polyester (GRP) enclosure with a protective stainless steel wire guard over the lens, the XB15 is built to withstand the corrosion, UV exposure, vibration and physical impact common in offshore and coastal industrial environments. The beacon carries a high IP66/IP67 ingress protection rating, ensuring reliable operation even when subjected to washdown, heavy rain or sea spray.

Supervised Alarm Circuit

The XB15 includes a supervisory diode and four-wire lead connection, allowing it to be integrated into a supervised alarm circuit that can detect wiring faults or beacon failure, an important feature for life-safety and process-critical alarm systems where a failed visual indicator could delay evacuation or fault response. Units are available in a range of lens colors (including red, amber, blue, green and clear) to match specific alarm coding schemes used across a facility.

Typical Applications

The XB15 is widely deployed as a process fault indicator, fire and gas detection alarm, emergency evacuation signal and general-purpose hazardous area visual alarm across oil and gas production facilities, LNG terminals, offshore platforms, petrochemical plants and marine vessels. It is frequently specified alongside MEDC and Eaton Crouse-Hinds audible alarm sounders to form a combined audio-visual alarm point at each hazardous area location.

Voltage and Mounting Options

The XB15 is available in AC and DC voltage variants (commonly 24V DC, 110V AC and 230V AC) and can be supplied for direct mount or pipe mount installation, allowing flexibility when retrofitting into an existing hazardous area alarm system or specifying a new installation. Units can also be supplied pre-painted to customer specification to match facility color-coding standards.

Alarm Coordination and Signal Coding

Because hazardous area facilities often need to distinguish between multiple alarm conditions — such as gas detection, fire, process fault and general evacuation — the availability of the XB15 in several lens colors allows a plant to implement a clear visual coding scheme across its alarm points. Combined with the beacon’s selectable flash rate and light output, this makes it straightforward to differentiate a critical gas alarm beacon from a lower-priority process fault indicator at a glance, even from a distance or through smoke and fog.

Integration with Fire and Gas Systems

The XB15 is commonly wired into a facility’s fire and gas (F&G) detection and alarm system, triggered automatically by the central F&G logic solver when a detector confirms a gas release, fire condition or other hazardous event. Its supervised circuit design means that a broken wire or beacon failure is reported back to the control system as a fault condition rather than failing silently, which is a critical requirement for safety instrumented systems operating to IEC 61508/61511 functional safety principles.

Selecting the Right Configuration

When specifying an XB15 beacon, engineers typically need to confirm the required light output (Joule rating), lens color, supply voltage, hazardous area certification (ATEX, IECEx or UL) and mounting style (direct or pipe mount) to match the installation. Because these variables affect both the part number and the beacon’s visibility performance in a given installation, Seven Star LLC can help cross-reference an existing installed base or a project specification against the current XB15 range to confirm the correct configuration before ordering.

Seven Star LLC also supplies compatible MEDC audible alarm sounders and junction boxes, allowing a complete combined audio-visual alarm point to be sourced from a single supplier for new installations or panel replacements.

Why Choose Seven Star LLC

Seven Star LLC supplies genuine MEDC and Eaton Crouse-Hinds hazardous area signaling equipment, including the XB15 Xenon beacon range, to oil and gas operators, EPC contractors and marine facilities across Oman and the wider GCC region. Our team can help confirm the correct voltage, lens color, mounting configuration and certification scheme for your hazardous area alarm system.

Because the XB15 remains one of the most widely installed beacon models across legacy and current MEDC and Eaton Crouse-Hinds hazardous area alarm systems, replacement units are frequently sourced for maintenance and panel upgrade projects rather than new-build installations, and Seven Star LLC can support both scenarios.

Our team can also advise on lead times for factory-specific paint finishes or certification documentation packages required for offshore procurement.

Cross-referencing older MEDC part numbers against current production is a service we regularly provide to facilities running long-life alarm system installations.

Get a Quote

Contact Seven Star LLC for pricing, lead time and technical specifications on the MEDC XB15 explosion-proof Xenon beacon, or for other MEDC and Eaton Crouse-Hinds audible and visual alarm devices for your hazardous area installation.

Browse the full MEDC range or see more Fire & Gas Detector products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet MEDC XB15 Explosion-Proof Xenon Beacon Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beacons, sounders and manual call points for hazardous areas are what MEDC is known for on offshore platforms, in refineries and in tank farms. Units in service may be labeled MEDC, Cooper MEDC or Eaton MEDC, and in each case the model code on the label identifies the product.

Seven Star LLC is an independent supplier listing MEDC explosion-protected beacons, alarm sounders, call points and junction boxes for fire and gas systems in Oman and the GCC.

MEDC product families on this page

Visual signals include the XB15 xenon beacon, the LD15 LED beacon and the SM87 beacon family with its SM87LED version, for Zone 1 and Zone 2 areas. The DB3 is the alarm sounder. Manual alarm devices are the BG manual call point and a manual release unit from the BG2 call point series, listed as BG2E. The SM87JB junction box completes the field wiring. These devices are ordered with long codes such as SM87BGLAD1T1B1NNRAS or BGEB4B6B1DDCF7R, in which each block of characters selects an option.

Where MEDC signaling equipment is used

MEDC beacons and sounders announce fire, gas and process alarms on production platforms, in gas plants, refineries, chemical plants, loading terminals and marine vessels. Call points give personnel a way to raise the alarm by hand, and the same devices are wired into fire and gas panels from many system builders.

Ordering MEDC beacons and call points: what we need

The complete order code from the label or the project datasheet is the best starting point. If you are selecting from scratch, send the supply voltage, lens color for beacons, tone and sound level for sounders, enclosure material and finish color, cable entry size and number, the certification required and the ambient temperature. For call points add the switch arrangement, any series or end-of-line resistor values, and label or duty plate text.

Frequently Asked Questions

What is the MEDC XB15 used for?
It is an explosion-proof Xenon beacon used for visual alarm signaling in hazardous area installations such as oil, gas and petrochemical facilities.
What hazardous area certifications does it hold?
The XB15 is certified for Zone 1 and Zone 2 hazardous locations under ATEX and IECEx schemes, with UL-listed variants also available.
What light output does the XB15 provide?
The XB15 range provides Xenon flashtube light output from 5 to 21 Joules depending on configuration.
Is the alarm circuit supervised?
Yes, the XB15 includes a supervisory diode and four-wire connection, allowing wiring faults or beacon failure to be detected by the alarm system.
How do I request a quotation for MEDC XB15 Explosion-Proof Xenon Beacon?
Send the model number, required quantity and delivery location through the quote request form or by email to Seven Star LLC. The sales team replies with availability, lead time and commercial terms for your Oman or GCC project.