Moore Industries SPA2 Programmable Limit Alarm Trip
Overview
Moore Industries SPA2 is a universal, site- and PC-programmable Limit Alarm Trip built to monitor a process signal and switch relay outputs the instant that signal crosses a configured high or low threshold. Engineers across oil & gas, power generation, water treatment and general process manufacturing rely on the SPA2 for on/off control, unwanted process condition warnings, rate-of-change alarming and emergency shutdown functions, all from a single DIN-rail mounted device with an integral display for local monitoring.
With engineering support in Muscat, Seven Star LLC supplies the Moore Industries SPA2 to end users, EPC contractors and system integrators throughout the Sultanate of Oman and the wider GCC. Every unit is supplied with manufacturer documentation and local technical support – important for safety and alarm-trip devices that protect the plant.
Measurement Principle of the Moore Industries SPA2
The Moore Industries SPA2 accepts a universal process input – RTD, thermocouple, millivolt, resistance (Ohms) or potentiometer – and continuously compares the linearized value against up to four independently configurable alarm setpoints. When the measured value crosses a programmed trip point, the corresponding relay output switches state, providing a dry-contact signal that can drive an annunciator, interlock a shutdown valve, start a backup pump or alert an operator through the plant control system. Deadband, time delay and latching behavior are all field-programmable, allowing the trip response to be tuned to the dynamics of the process rather than forcing the process to accommodate a fixed alarm behavior.
Because the SPA2 performs true digital signal linearization internally before the comparison is made, alarm accuracy is not degraded by sensor non-linearity across the measurement span, and rate-of-change alarming can be configured to catch a fast-moving excursion before it reaches the absolute trip point. The practical consequence for the plant is a single, self-contained protection layer that requires no external computation, no moving parts to wear, and no separate transmitter and trip-amplifier pairing – the SPA2 measures, linearizes and trips in one housing, reducing both installation complexity and the number of failure points in the safety loop.
Engineering Design of the Moore Industries SPA2
The Moore Industries SPA2 ships in a compact DIN-rail housing that snaps directly onto standard 35mm top-hat rail, minimizing panel space and simplifying retrofit into existing marshalling cabinets. Universal 4-wire power supports 21.6–375Vdc or 90–260Vac, so the same model can be specified across mixed DC and AC control philosophies without re-ordering a different power variant. An integral digital display shows the live process value directly on the front face, along with READY, INPUT and individual TRIP status LEDs, giving technicians instant visual confirmation of alarm state without opening a laptop or DCS screen.
Configuration is done either from the front-panel UP, DOWN and SELECT push-buttons for quick field adjustments, or via USB cable and Moore Industries’ PC configuration software for full parameter programming, setpoint documentation and configuration backup. An optional programmable analog output (any range between 0–20mA and 0–10V) lets the SPA2 simultaneously retransmit a scaled process signal to a DCS or PLC while independently performing its alarm-trip function, and the unit carries Non-Incendive/Division 2, Zone 2 hazardous area certification for installation in classified areas common to oil & gas and petrochemical facilities.
Key Features
The Moore Industries SPA2 combines universal input compatibility with flexible alarm logic and hazardous-area readiness, making it a dependable choice wherever independent limit protection is required:
- Accepts RTD, thermocouple, millivolt, Ohms and potentiometer inputs from a single universal input stage, removing the need to stock model variants per sensor type.
- Provides up to two or four independently programmable relay alarm outputs depending on configuration, each with adjustable setpoint, deadband, time delay and latching.
- Supports rate-of-change alarming to detect a dangerously fast process excursion before the absolute limit is reached.
- Optional programmable analog output retransmits a scaled 0–20mA or 0–10V signal for simultaneous monitoring and alarming from one device.
- Integral digital display and READY/INPUT/TRIP status LEDs give immediate local visibility of process value and alarm state.
- Universal 4-wire power input (21.6–375Vdc or 90–260Vac) simplifies specification across mixed DC and AC installations.
- Non-Incendive/Division 2, Zone 2 hazardous area certification supports safe deployment in classified oil & gas and petrochemical areas.
- Compact DIN-rail housing and front-panel or USB/PC configuration reduce both panel footprint and commissioning time.
Industrial Applications
The Moore Industries SPA2 is widely deployed across oil & gas production and refining, power generation, water and wastewater treatment, and general process manufacturing wherever an independent, hard-wired limit alarm is needed alongside – or as a backup to – the primary DCS or PLC. Typical duties include high-temperature shutdown on rotating equipment bearings, low-flow protection on pump seal water, tank high-level alarms in tank farms and storage terminals, and rate-of-change monitoring on reactors and heat exchangers where a fast excursion demands immediate isolation.
Backed by genuine manufacturer documentation, Seven Star LLC distributes and supports the SPA2 across Oman’s industrial base, including the Sohar and Salalah economic zones, Duqm’s refining and petrochemical cluster, and upstream oil & gas operations throughout the Sultanate. Facility engineers and instrumentation teams across the GCC specify the SPA2 through Seven Star LLC for its combination of universal input flexibility and certified hazardous-area readiness, with local technical support.
Technical Specifications
The table below summarizes the core specifications of the Moore Industries SPA2 Programmable Limit Alarm Trip:
| Parameter | Specification |
|---|---|
| Model | SPA2/TPRG/2PRG/U/-AO [DIN] |
| Input Types | RTD, Thermocouple, mV, Ohms, Potentiometer (programmable) |
| Alarm Outputs | 2 or 4 independently programmable relay outputs |
| Analog Output (Option -AO) | Programmable, any range between 0–20mA and 0–10V |
| Power Supply | Universal 4-wire: 21.6–375Vdc or 90–260Vac |
| Display | Integral digital display with READY/INPUT/TRIP status LEDs |
| Configuration | Front-panel push-buttons or USB cable with PC configuration software |
| Housing | DIN-rail enclosure, mounts on 35mm top-hat rail |
| Hazardous Area Certification | Non-Incendive/Division 2, Zone 2 |
| Compliance | RoHS Compliant |
Request a Quote for Moore Industries SPA2 Programmable Limit Alarm Trip
Seven Star LLC is ready to support your formal RFQ for the Moore Industries SPA2 Programmable Limit Alarm Trip, and our team can confirm current availability and lead time on request, with full technical datasheets available on request, and direct access to our instrumentation division for application sizing and configuration guidance. Working closely with plant engineers in the region, we support every SPA2 enquiry with local engineering support – contact Seven Star LLC today to request a quotation or a technical consultation.
Related Products
- 16137-224 – Siemens APACS+/QUADLOG I/O BUS A Side Cable (2.5 M)
- TI TMS320F28335PGFA Digital Signal Controller
- ABB RVG200.A6A6.YO.D.0.A.1.A.1.A.5.Y Touchscreen Paperless Recorder
- JUMO DICON touch Process and Program Controller
- Fuji Electric France PDA312C1-BCYCD-10 Digital Temperature Controller
- Fluidwell F114 Ratio Monitor / Totalizer
- Datasheet Moore Industries SPA2 Programmable Limit Alarm Trip Datasheet Download
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and the items listed here map onto it directly:- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.

Reviews
There are no reviews yet.