Panametrics HygroProII Intrinsically Safe Moisture Transmitter
Description
HygroProII intrinsically safe moisture transmitter
The Panametrics HygroProII is a loop-powered aluminum oxide moisture transmitter with its own display, designed to measure water content in gases and non-aqueous liquids from trace levels up to ambient. It combines an advanced thin-film aluminum oxide sensor with a built-in thermistor, an optional pressure transducer and a backlit 128 by 64 LCD that shows up to three parameters at once. Certified intrinsically safe when installed with suitable associated apparatus, and housed in an IP66, IP67 and Type 4X enclosure, the HygroProII is built for pipeline natural gas, petrochemical plants, power generation and industrial gas supply, along with semiconductor, furnace gas, air dryer, pharmaceutical and aerospace uses.
Key points of HygroProII
- Ambient to ppb-level moisture measurement with a next-generation aluminum oxide sensor.
- Calculates ppmv in gases, ppmw in liquids, pounds per million standard cubic feet in natural gas and percent relative humidity from dew point, temperature and pressure.
- Field-replaceable transducer element (RTE) that holds the sensor, thermistor and optional pressure transducer; calibration data stay in non-volatile EEPROM inside the RTE, so nothing is keyed in after a swap.
- Built-in HART multi-drop networking over the 4-20 mA loop.
- Desiccant packs in an aluminum cap keep the probe dry until installation, then fast dry-down follows when the cap is removed.
- Calibration traceable to NIST or NPL, with an ISO 17025 accredited option.
HygroProII technical specifications
| Parameter | HygroProII |
|---|---|
| Calibration range (dew/frost point) | 10 to -80 C (50 to -112 F) with data from 20 to -110 C |
| Accuracy | 2 C above -100 C; 3 C below -100 C |
| Repeatability | 0.2 C above -100 C; 0.5 C below -100 C |
| Operating pressure | 5 micron Hg to 5000 psig (345 bar) |
| Process connection | 3/4-16 in (19 mm) straight male thread with O-ring; G 1/2 with optional adapter |
| Power and output | 12 to 28 VDC loop powered; 4-20 mA with HART; 0.01 mA / 12-bit resolution |
| Cable | 6 ft (2 m) or 30 ft (10 m) with molded connector and flying leads |
| Enclosure and size | Type 4X, IP66, IP67; 7.88 x 3.99 x 2.56 in (200 x 101 x 65 mm); 2.53 lb (1147 g) |
| Temperature sensor | NTC thermistor, -30 to 70 C, 0.5 C overall accuracy |
| Pressure sensor (optional) | Piezoresistive; ranges 30-300, 50-500, 100-1000, 300-3000 or 500-5000 psig; 1% of full scale |
| Ambient | -20 to 60 C operating; -40 to 70 C storage |
| Hazardous area | Class I Div 1 A, B, C, D T4; Zone 0 AEx ia IIC T4 Ga; ATEX/IECEx Ex ia IIC T4 Ga; single seal per ANSI/UL 122701 |
How HygroProII differs from other Panametrics moisture probes
Compared with the bare M Series and IQ.probe sensors, which need a separate analyzer such as the dew.IQ, the HygroProII bundles the sensor with display, keypad and loop-powered electronics. Compared with the HygroPro replacement transducer element listed separately, the HygroProII is the complete transmitter. Its operating pressure of 5000 psig is high for a hygrometer, and the optional pressure transducer lets it report moisture in engineering units that depend on pressure, such as ppmv and pounds per million standard cubic feet.
Three sensors on one mount
Moisture sensor, thermistor and pressure sensor share one probe mount, with a glass-to-metal seal certified to the ANSI/UL 122701 single seal standard, isolating the electronics from the process. This also allows real-time temperature compensation of the raw moisture reading and keeps the installation compact where space is limited.
Applications in Oman and the GCC
Gas export and transmission lines need water dew point monitoring against contract limits, and refinery and petrochemical streams need dryness checks upstream of catalysts. Industrial gas producers verify nitrogen, hydrogen and argon quality, and power plants check generator and instrument gas. For hydrocarbon liquids the ppmw output is meaningful. Because the unit is intrinsically safe and loop powered, it can be installed in classified areas with an associated barrier.
Reading the display and outputs is straightforward. The 6-button keypad and backlit screen let an operator view one to three parameters and diagnostics, for example dew or frost point together with temperature and pressure, without a handheld communicator. The 4-20 mA loop carries the primary variable to the control system, while HART over the same wires gives access to the other values and to configuration. The built-in multi-drop capability lets several units share a network, which is useful on a pipeline with a string of measurement stations or on a plant with many dryers. A typical hazardous-area installation uses an optional resistively limited isolation barrier between the transmitter and the analog or HART master device, and the cable is available in 2 m and 10 m lengths with a molded weatherproof connector so that field wiring is limited to the flying leads.
Because aluminum oxide sensors are sensitive to the history of exposure, the dry cap matters in practice: keep the desiccant cap on until the transmitter is about to be installed so the sensor does not pick up moisture from ambient air, and expect a short dry-down time after installation. For sample-line installations, locate the probe where the gas is representative, avoid dead legs and long unheated tubing, and make sure the pressure at the sensor is the pressure used in any ppmv calculation.
Installation and servicing
Unscrew the desiccant cap just before installing, screw the 3/4-16 in thread into the sample port, and connect the 4-20 mA loop through an isolation barrier where required. Configure units, range and HART address from the keypad. Panametrics recommends recalibrating the moisture sensor every six to twelve months depending on the application; the RTE can be replaced by loosening a couple of screws and disconnecting the internal cable.
Supplier note
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and can quote replacement transducer elements for installed HygroProII units.
Documents and quotation
The manufacturer datasheet for HygroProII is provided. In your RFQ quote HygroProII, cable length, pressure sensor range, process thread, calibration option and quantity.
Other Models in the Panametrics Moisture Range
Seven Star LLC supplies models from the Panametrics Moisture range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Panametrics PM880 Portable Hygrometer for Trace Moisture | Humidity & Dew Point Instruments | View details |
| Panametrics pro.IQ Moisture Analyzer Packaged Solution | Humidity & Dew Point Instruments | View details |
| Panametrics HygroProII Intrinsically Safe Moisture Transmitter | Humidity & Dew Point Instruments | You are viewing this model |
Datasheets & Documents
- Datasheet Panametrics HygroProII Intrinsically Safe Moisture Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics HygroProII Intrinsically Safe Moisture
Answers from our engineering team on installation, compatibility and integration.
01What does the HygroProII measure?
Moisture in gases and non-aqueous liquids from trace to ambient level, plus temperature and optional pressure, from which ppmv, ppmw and relative humidity are calculated.
02Is HygroProII intrinsically safe?
Yes, it carries Class I Division 1, Zone 0 AEx ia and ATEX/IECEx Ex ia IIC T4 Ga certification when installed with suitable associated apparatus.
03How is the HygroProII sensor replaced?
The field-replaceable transducer element is removed by loosening mounting screws and disconnecting one internal cable; calibration data are stored in the element.
04What is the maximum operating pressure of HygroProII?
The datasheet gives 5 micron Hg to 5000 psig (345 bar).
05How often should HygroProII be recalibrated?
Panametrics recommends moisture sensor recalibration every six to twelve months depending on the application.