Brand: MICHELL Instruments
MICHELL Instruments SF52 Dew-Point Transmitter for Dryers
Description
Overview
Compressed air dryers need a sensor that survives vibration, condensate and years of duty without costing as much as a laboratory instrument. The MICHELL Instruments SF52 is built for that: a compact polymer-based dew-point transmitter with a recessed, protected measuring element, a nickel-coated brass body and a choice of G1/2 inch BSP or 1/2 inch NPT process connections. It measures minus 40 to plus 60 degrees Celsius dew point and offers voltage or milliamp outputs. Seven Star LLC is an independent supplier serving Oman and the GCC.
Main characteristics of the MICHELL Instruments SF52
- Recessed measuring element behind an HDPE front filter extends sensor life.
- Three-point traceable calibration certificate supplied with each unit.
- Voltage outputs 0-1, 0-5 or 0-10 V, or 4-20 mA in a three-wire connection.
- IP66 and NEMA 4 protection, CE marked, with 2 m of halogen-free TPE cable.
- Factory-programmed diagnostics: 23 mA for sensor fault, 4 mA under-range, 20 mA over-range.
MICHELL Instruments SF52 specifications
| Measurement range | -40 to +60 C (-40 to +140 F) dew point |
|---|---|
| Accuracy | Plus or minus 2 C (3.6 F) dew point |
| Repeatability | 0.5 C (0.9 F) dew point |
| Absolute humidity accuracy | 0.4 to 3 g/m3 |
| Stability | Less than 1 C (1.8 F) per year |
| Output signal | 0-1, 0-5, 0-10 V or 4-20 mA (3-wire) |
| Outputs available | Dew point or absolute humidity |
| Standard scaling | -40 to +60 C dp; -30 to +30 C dp; 0 to 200 g/m3 |
| Supply voltage | 14 to 30 V DC for 0-10 V; 8 to 30 V DC for 0-1 V, 0-5 V or 4-20 mA |
| Current consumption | Voltage output less than 9 mA; mA output less than 29 mA |
| Operating pressure | 2 MPa (20 barg / 290 psig) maximum |
| Operating temperature / humidity | -40 to +60 C; 0 to 100 percent RH |
| Housing | Nickel-coated brass, IP66 / NEMA 4 |
| Dimensions | Length 85 mm, diameter 24 mm maximum |
| Weight | 320 g (11.3 oz) |
| Filter | HDPE front filter |
| Process connection | G1/2 inch BSP or 1/2 inch NPT |
Sensor technology and calibration
The polymer-based sensing element is calibrated on a high volume traceable calibration system, which lets the manufacturer ship OEM quantities quickly while still supplying a three point certificate with each transmitter. Thermal compensation is characterized across the operating range, so the stated plus or minus 2 C accuracy holds as the process temperature changes.
Typical applications in Oman and the GCC
The datasheet positions the SF52 for OEM dryer use in harsh industrial environments. In Oman and the GCC that means desiccant and refrigerated air dryers at workshops, fabrication yards, bottling and packaging lines, mining sites and utility compressor houses, where a low-cost dew-point signal can drive dryer purge control or a high dew point alarm.
How SF52 differs from SF72 Rail and SF82
- SF52 measures -40 to +60 C dew point with 0.5 C repeatability and a 2 MPa pressure limit; SF72 Rail covers -60 to +60 C dew point at 45 MPa.
- SF52 housing is nickel-coated brass with a fixed cable; SF72 Rail is 316 stainless steel with an M12 connector.
- SF52 outputs are voltage or 4-20 mA in three wire form; SF72 Rail is a two wire 4-20 mA loop with Modbus RTU diagnostics.
Choosing the output of the MICHELL Instruments SF52
The same body is offered with voltage or milliamp outputs, so the choice depends on the receiving equipment and the cable run. The 0-10 V version needs a supply of 14 to 30 V DC, whereas the 0-1 V, 0-5 V and 4-20 mA versions work from 8 to 30 V DC, which suits small controllers and OEM panels with limited supply headroom. Current loops tolerate longer cable and electrical noise better, while voltage outputs suit a short run to a nearby controller input. In either case the output can represent dew point or absolute humidity, and non-standard scaling is available on request.
Integration with dryer control
In a desiccant dryer the dew-point signal can switch between towers, extend a purge cycle only when the outlet dew point is poor, or raise an alarm when the dryer fails to reach its target. In a refrigerated dryer it confirms that the air leaves below the plant threshold. The recessed element and HDPE filter keep liquid droplets and dust away from the polymer sensor, which is why the datasheet highlights extended sensor life. For OEM builders, short delivery of volume quantities and a certificate with each unit streamline production testing.
A well-specified order lists the process connection (G1/2 BSP or 1/2 NPT), the output, the range, and any certificate needed with delivery, so that the unit arrives ready to install.
Installation and commissioning
Thread the transmitter into the dryer outlet or a sample block using the G1/2 BSP bonded seal or the 1/2 NPT thread, keeping gas pressure below 2 MPa. Wire white to power, green to output and brown to common ground. Set the scaling in the receiving device to match the factory range, and use the diagnostic currents to detect faults.
Maintenance
Keep the HDPE front filter clean and replace it if oil aerosol blocks it. Recalibration against a traceable reference at a plant-defined interval keeps drift below the 1 C per year stability figure.
Related products and ordering notes
For a quotation on SF52, give the process connection, the output type, and the scaling range. OEM volume requirements can be stated in the RFQ.
Related items you may also need: Michell MDM300-IS Intrinsically Safe Portable Hygrometer | Michell OPT501 Optidew 501 Wall Mount Chilled Mirror Hygrometer | Michell CD2-WDC-002 Water Dew-Point Sensor Assembly | All MICHELL Instruments products.
Purchasing teams ordering the MICHELL Instruments SF52 for a shutdown or maintenance window should state the required delivery date and the destination in Oman or the wider GCC in their first message. With that information the team can confirm availability, plan transport and prepare the supporting documents without extra rounds of correspondence.
Configuring the MICHELL Instruments SF52 for your process
The MICHELL Instruments SF52 is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.
- Measuring range and the gas or sample the MICHELL Instruments SF52 will analyse.
- Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
- Supply voltage and the mounting style required on site.
- Hazardous area classification of the installation location, if any.
- Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.
Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.
Documents and quotation
The datasheet for the SF52 is attached on this page. To check availability, send an RFQ to Seven Star LLC with the part number SF52, the quantity and your destination in Oman or the GCC.
Datasheets & Documents
- Datasheet MICHELL Instruments SF52 Dew-Point Transmitter for Dryers Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the MICHELL Instruments SF52 Dew-Point Transmitter for
Answers from our engineering team on installation, compatibility and integration.
01What range does the SF52 cover?
The SF52 measures -40 to +60 C dew point with plus or minus 2 C accuracy, 0.5 C repeatability and stability of less than 1 C per year.
02What outputs does the SF52 offer?
It offers 0-1, 0-5 or 0-10 V or 4-20 mA in a three-wire connection, scaled to dew point or absolute humidity, with standard range -40 to +60 C.
03What process connections does the SF52 have?
The process connection is G1/2 inch BSP or 1/2 inch NPT, in a nickel-coated brass housing with HDPE front filter.
04What is the maximum pressure for the SF52?
The maximum operating pressure is 2 MPa (20 barg, 290 psig); ingress protection is IP66 and NEMA 4.
05What diagnostics does the SF52 give?
Factory-programmed conditions give 23 mA for a sensor fault, 4 mA for under-range dew point and 20 mA for over-range dew point on the current output.