Brand: MICHELL Instruments
Michell EA-PDP-B Easidew PDP Dryer Portable with SF82
Description
Michell EA-PDP-B fast-response dryer portable with SF82 sensor
The Michell EA-PDP-B is the second member of the Easidew PDP Dryer Portable pair, supplied with an SF82-TX-M12 polymer thick-film dew-point transmitter instead of the metal-oxide transmitter used in EA-PDP-A. The change brings a response of 3 minutes to T95 (dry to wet, -40 to +10 °C dew point) and an extended upper range of +60 °C dew point, so the instrument is the practical pick for Class 2 to Class 4 compressed-air work. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What the EA-PDP-B user sees
A 3.5 inch touchscreen shows dew point, pressure and temperature, with a history graph that draws the dryer outlet’s dew-point and pressure curves over time. The housing is a lifetime-warranty polypropylene case with IP65 protection closed and IP54 open, and the touchscreen and front panel are IP54. The whole assembly is certified for heavy industrial RFI and EMC conditions and is built to resist drops.
EA-PDP-B performance and specification
| Part number | EA-PDP-B |
| Dew-point sensor | SF82-TX-M12, polymer thick-film |
| Moisture range | -60 to +60 °C (-76 to +140 °F) dew point |
| ISO 8573-1 class | Class 2 to Class 4 |
| Accuracy | ±2 °C (±3.6 °F) dew point |
| Response, dry to wet | 3 minutes to T95, -40 to +10 °C dew point |
| Repeatability | 0.5 °C (0.9 °F) dew point |
| Calibration | traceable 9-point, in 10 °C steps from -60 to +20 °C |
| Sensor guard | HMWPE, under 10 µm |
| Pressure sensor | internal, up to 20 barg |
| Battery | lithium-ion, 2 working days power-save |
| Display | 3.5 inch LCD touchscreen, 640 x 480 pixels |
| Memory and transfer | 2 GB SD card, USB-C, TXT file |
| Weight | 3.6 kg |
How EA-PDP-B differs from EA-PDP-A
The most useful comparison is the moisture limit. EA-PDP-B stops at -60 °C dew point and therefore cannot demonstrate Class 1, whereas EA-PDP-A reaches -100 °C. In return EA-PDP-B responds in 3 minutes and measures up to +60 °C dew point, uses an HMWPE guard (the other uses HDPE), and carries a 9-point calibration against 13 points. Spare guard packs follow this difference: SF82-HMP for EA-PDP-B and EA2-HDPE for EA-PDP-A. Sensor exchange is SF82-TX-X-CAAB and recalibration SF82-TX-Recal.
When to specify EA-PDP-B
Choose it for refrigerant dryers, membrane and pressure-swing dryers whose outlet dew point is not far below -40 °C, plastic-moulding drying systems, railway pneumatics and additive-manufacturing gas supplies. Compressed-air quality checks in manufacturing plants and utilities in the Gulf rarely go below -40 °C, where this variant’s speed saves time at every test point. The wider upper range also makes it suitable for confirming that an aftercooler or refrigerant dryer is working at all, because a reading near ambient dew point immediately shows a failed unit. Buyers who are unsure should compare their dryer’s guaranteed pressure dew point with the -60 °C limit of this sensor: if the guarantee is -40 °C or warmer, EA-PDP-B is adequate, and if it is -70 °C the EA-PDP-A variant is the correct choice.
Using EA-PDP-B on site
Connect the 2 m PTFE 6 mm tube through the Legris push-fit 1/8 inch BSPP fittings (Swagelok 6 mm and 1/4 inch adaptors are optional), set flow near 1 to 5 Nl/min and keep the maximum at 15 Nl/min. Standard filtration in the block removes 99.5 percent of particles of 0.1 µm and larger, and ten spare cartridges come with the kit. The optional outlet pigtail should be fitted when moisture back-diffusion matters.
Polymer sensing technology inside EA-PDP-B
The SF82-TX-M12 is Michell’s advanced thick-film, fast-response dew-point sensor, tuned for industrial dryers where speed matters. Because it covers -60 to +60 °C dew point, it also lets an engineer see wet-side conditions upstream of a dryer, which the narrower metal-oxide variant cannot. Calibration is performed in 10 °C steps from -60 to +20 °C and every unit ships with its traceable certificate. The datasheet’s accuracy of ±2 °C dew point applies over the compensated temperature range of -20 to +50 °C, so test only within that window and let the instrument stabilise after moving from a cold store to a warm plant room.
Logging and quality reports with EA-PDP-B
Each measurement stores dew point, pressure, temperature, time and date to the 2 GB SD card, and the TXT file opens in any spreadsheet after a USB-C download to a laptop. The calculated atmospheric dew point is helpful when the specification is quoted at atmospheric pressure but the gas is tested under pressure. Operators can display the pressure dew point or the atmospheric value, and use the graph to record the dry-down curve for a service report. The unit meets EN 61010-1:2010+A1:2019 and is certified for heavy industrial RFI and EMC.
Accessories listed for EA-PDP-B
SF82-HMP (ten HMWPE guards), EA-PDP-CHA charger, EA-PDP-PIG pigtail, SSF-PF-10PK filter cartridges, PDP-2PK-FIT-A, -B and -C fitting packs, and PTFE-xx tubing, all from the order-code sheet. The fitting packs are worth planning: PDP-2PK-FIT-A converts 6 mm Swagelok to 1/8 inch BSPP, PDP-2PK-FIT-B converts 1/4 inch Swagelok to 1/8 inch BSPP, and PDP-2PK-FIT-C is a Legris quick-connect for 6 mm PTFE tube that the sheet marks as low pressure only. Ordering the right pack at the start avoids improvised adaptors on a live air line. Because the stainless sample block and tube are fixed, the only consumables that normally need replacing on EA-PDP-B are the sensor guard and the cartridge in the block, and both are kept inside the lid pocket alongside the stylus and cable so a technician is never left without them at a remote dryer.
Documents and quotation
The datasheet is provided as a PDF. For a quote on EA-PDP-B, send your RFQ listing the part number, quantity, outlet fitting preference and charger or spare requirements.
Other Models in the Michell Easidew Pdp Range
Seven Star LLC supplies models from the Michell Easidew Pdp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell EA-PDP-B Easidew PDP Dryer Portable with SF82 | Humidity & Dew Point Instruments | You are viewing this model |
| Michell EA-PDP-A Easidew PDP Dryer Portable Hygrometer | Humidity & Dew Point Instruments | View details |
Datasheets & Documents
- Datasheet Michell EA-PDP-B Easidew PDP Dryer Portable with SF82 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell EA-PDP-B Easidew PDP Dryer Portable with
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between EA-PDP-B and EA-PDP-A?
EA-PDP-B uses an SF82-TX-M12 polymer sensor (-60 to +60 °C dew point, 3 minute response, Class 2 to 4), while EA-PDP-A uses the Easidew EA2-TX-M12 reaching -100 °C.
02Which ISO 8573-1 classes does EA-PDP-B cover?
The datasheet lists Class 2 to Class 4 moisture compliance for EA-PDP-B. Class 1 testing needs the EA-PDP-A version with the lower range.
03What guard protects the EA-PDP-B sensor?
The SF82 sensor has an HMWPE guard for particles under 10 µm; a ten-pack of replacements is listed as SF82-HMP.
04How is EA-PDP-B calibrated?
It carries a traceable 9-point calibration certificate in 10 °C dew-point steps from -60 to +20 °C. Recalibration is listed as SF82-TX-Recal.
05What accessories ship with EA-PDP-B?
The kit includes a 2 m PTFE 6 mm tube, ten inlet filter spares, a 1.5 m USB-C cable, a screen stylus and a calibration certificate.