Brand: Legrand
Legrand 411053 DX3 1P+N 32 A RCBO 30 mA Type A
Description
411053: Legrand DX3 6000 1P+N 32 A RCBO, type A 30 mA, 10 kA
The Legrand 411053 is a compact DX3 6000 RCBO for one phase plus neutral at 230 V AC. It is rated 32 A on a C curve, has a 30 mA type A residual current function and a 10 kA breaking capacity under IEC 60947-2. The catalogue notes that it fits prong and fork busbars, accepts DX3 signalling and remote-trip auxiliaries, and is two modules wide with the neutral on the right. Seven Star LLC supplies 411053 in Oman and the GCC as an independent supplier in Muscat.
This is the plain type A version of the 1P+N family; its high-immunity F-type sibling is 411097. The two devices share dimensions and rating, so the choice comes down to the load: standard resistive and motor loads are fine with type A, while heavily electronic circuits favour F.
Reading the 411053 reference
| Element | Value | Meaning |
|---|---|---|
| RCBO DX3 6000 | Product | Residual current breaker with overcurrent protection |
| 1P+N | Poles | Protected phase plus switched neutral, two modules |
| 32 A, C curve | Overcurrent | Magnetic trip 160 to 320 A |
| Type A, 30 mA | Residual | AC and pulsating DC leakage, 30 mA |
| 10 kA | IEC 60947-2 | Breaking capacity at 230 V; 6 kA under EN 61009 |
| Ref. 411053 | Catalogue number | Reference to quote |
Technical specifications for 411053
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Legrand / 411053 (DX3 RCBO 6000, 1P+N, 32 A, C, 30 mA, type A) |
| Poles | 2 total (1 protected phase pole plus neutral) |
| Rated current / curve | 32 A / C |
| Rated residual current | 30 mA, leakage type A |
| Rated voltage / frequency | 230 V AC, 50 Hz |
| Breaking capacity | Icn 6 kA (EN 61009-1); 10 kA under IEC 60947-2 |
| Current limiting class | 3 |
| Surge current capacity | 0.25 kA |
| Anti-nuisance tripping version | No |
| Width / built-in depth | 2 modular spacings / 44 mm |
| Conductors | Solid-core 0.75–16 mm²; multi-wire 0.75–10 mm² |
| Protection / pollution | IP20, pollution degree 2 |
| Mounting | 35 mm DIN rail; prong and fork busbars; supply from top or bottom |
How 411053 handles faults
Overcurrent protection acts on the phase conductor: a thermal element for overload and a magnetic element for short circuit, the latter tripping between 160 and 320 A for a 32 A C-curve device. For earth leakage, the residual transformer monitors phase and neutral. When the imbalance reaches the 30 mA threshold the device opens. Because it is type A, it also responds to residual currents with a pulsating DC component, which are produced by rectifier-fed equipment such as some power supplies and variable-speed appliances.
The data sheet for the 1P+N family explains that the neutral pole provides isolation only and that its contact closes before and opens after the phase contact. This ordering avoids a situation where a phase is live while the neutral is open. A yellow indicator on the front marks a trip caused by the residual function, which helps diagnose the cause quickly.
Where 411053 fits and related parts
Use 411053 on single-phase final circuits that need individual leakage protection, such as sockets in a workshop, a water heater or a split air-conditioner. For loads with inverters, the F-type 411097 offers higher surge immunity; for double-pole disconnection, the AC-type 411161 uses four modules; and for three-phase circuits the 4-pole 411189 and 411192 apply. The data sheet range runs from 3 to 40 A with AC, A and F types and 10, 30 and 300 mA options, so the same body covers many duties.
Selection checklist for 411053
- Circuit: single-phase 230 V AC, 32 A or less.
- Residual type: A for AC plus pulsating DC; F for heavy electronic loads.
- Sensitivity: 30 mA people protection.
- Isolation: only the phase is protected, so the neutral is isolated but not overcurrent protected.
- Fault level: 10 kA under IEC 60947-2.
- Space: two modules, good for dense boards.
Installation, testing and maintenance of 411053
Fit the RCBO on the rail, observe the phase and neutral terminal marking, and tighten the screws to the recommended torque. Use solid conductors up to 16 mm² or flexible up to 10 mm². After energising, test with the front button and log the result with the reference 411053. The device can be changed in the middle of a busbar row without disturbing neighbouring products, according to the data sheet. After a residual trip, check the appliance and cable before reset; repeated trips indicate a real leakage path.
Typical applications in Oman and the GCC
Single-phase circuits for office sockets, accommodation blocks, workshop benches and utility points use type A RCBOs in boards across Oman and the GCC. High heat and dust in site cabins and kiosks argue for closed, ventilated boards and regular testing of the residual function, because a stuck mechanism may not trip when needed.
Information to send with an RFQ for 411053
- Reference 411053 and the quantity, including spares for panel maintenance.
- Rated current (32 A), curve (C), sensitivity (30 mA) and type (A).
- Nature of the load, including any electronic or inverter equipment.
- Board layout and busbar type.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as a technical data sheet or a compliance statement.
Storage, handling and spares for the Legrand 411053
Keep Legrand 411053 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the Legrand 411053 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The Legrand technical data sheet that covers 411053 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.
To request a quotation, send reference 411053, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.
Other Models in the Legrand Dx3 Rcbo 1pn Range
Seven Star LLC supplies models from the Legrand Dx3 Rcbo 1pn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Legrand 411097 DX3 1P+N 32 A RCBO 30 mA F Type | Circuit Breakers | View details |
| Legrand 411053 DX3 1P+N 32 A RCBO 30 mA Type A | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Legrand 411053 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.
Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.
Legrand company profile
| Headquarters | Limoges, France |
|---|---|
| Listing | Euronext Paris |
| Brands | Legrand, Bticino, Cablofil, Zucchini |
| Product families | DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS |
Legrand DX3 circuit breakers
DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.
Ordering Legrand breakers: what we need
Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.
Facts checked against Legrand's published corporate information, October 2026.
Browse Legrand products by category: Circuit Breaker.
FAQ
Questions about the Legrand 411053 DX3 1P+N 32 A RCBO 30 mA Type A
Answers from our engineering team on installation, compatibility and integration.
01What is 411053?
It is a Legrand DX3 6000 RCBO for one phase plus neutral, 32 A, C curve, with 30 mA type A residual current protection and 10 kA breaking capacity under IEC 60947-2.
02What does type A mean for 411053?
Type A detects sinusoidal AC and pulsating DC residual currents. It does not carry the extra high-frequency immunity of the F-type 411097.
03How wide is 411053?
The device occupies two modular spacings, with a built-in depth of 44 mm, and fits prong and fork-type busbars as described on the product page.
04Does the neutral pole of 411053 have overcurrent protection?
No. The data sheet states that the phase pole gives protection and isolation, while the neutral pole only gives isolation and closes before and opens after the phase.
05What conductors can connect to 411053?
The terminals take 0.75 to 16 mm² solid-core and 0.75 to 10 mm² multi-wire copper, per the product page.