Legrand 420207 DPX3 250 Thermal-Magnetic MCCB 3P 160 A
Description
420207: Legrand DPX3 250 thermal-magnetic MCCB, 160 A, 25 kA, 3P
The Legrand 420207 is a DPX3 250 thermal-magnetic moulded-case circuit breaker with three poles, a rated current of 160 A and a 25 kA breaking capacity at 400 V. Unlike the magnetic-only versions, it has an adjustable thermal release (128 to 160 A, 0.8 to 1.0 times In) and an adjustable magnetic release (800 to 1600 A), so one device covers overload and short circuit. Seven Star LLC supplies 420207 in Oman and the GCC as an independent supplier in Muscat.
The catalogue lists screw connection on the front side, a wing-knob control, fixed built-in construction and a motor operator as an option. The data sheet describes the DPX3 platform as aimed at medium-power distribution in commercial and industrial installations.
Reading the 420207 description
| Element | Value | Meaning |
|---|---|---|
| DPX3 250 | Frame | Moulded-case frame for 100 to 250 A |
| 3 pole 160 A | Poles and rating | Three poles; 160 A rated current |
| Thermal magnetic | Trip unit | Overload (thermal) and short-circuit (magnetic) release |
| 25 kA | Breaking capacity | Icu at 380/415 V; 36 kA and 50 kA references also exist |
| Ir 128–160 A | Overload setting | 0.8 to 1.0 x In |
| Ref. 420207 | Catalogue number | Reference to quote |
Technical specifications for 420207
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Legrand / 420207 (DPX3 250 thermal-magnetic, 3P, 160 A, 25 kA) |
| Type of protection | Thermal-magnetic |
| Poles / rated current | 3 / 160 A |
| Thermal setting Ir | 128 to 160 A (0.8 to 1 x In) |
| Magnetic setting Ii | 800 to 1600 A (5 to 10 x In) |
| Rated voltage | 220–690 V AC (Ue 690 V, Ui 800 V, Uimp 8 kV) |
| Breaking capacity Icu (IEC 60947-2) | 25 kA at 380/415 V; 40 kA at 220/240 V; Ics 100 % of Icu; Icm 52.5 kA at 415 V |
| Utilisation category / isolation | A / suitable for isolation |
| Endurance | Mechanical 20,000 cycles; electrical 8,000 at In and 10,000 at 0.5 In |
| Dimensions 3P / weight | 105 x 165 x 82.5 mm / about 1.9 kg |
| Protection / control | IP30, wing-knob handle, front screw connection, fixed version |
| Operating temperature | -25 to 70 °C; maximum terminal temperature 125 °C |
| Auxiliaries (catalogue) | One normally closed and one change-over auxiliary contact listed; motor drive optional |
How 420207 handles overload and short circuit
The thermal release is a bimetal element that bends in proportion to the heat from the load current. Set at 160 A it allows continuous operation at full rating, and a lower setting down to 128 A tunes the breaker to a smaller load or cable. A time-delay characteristic lets brief overloads pass but opens the circuit if the overload persists. The magnetic release is adjustable between 5 and 10 times the rating and acts within milliseconds on a short circuit.
Because the thermal element responds to temperature, the data sheet provides a derating table. For the 160 A rating the maximum long-time setting is 163 A at 30 °C, 160 A at 40 and 50 °C, 143 A at 60 °C and 134 A at 70 °C. That table is valuable in the Gulf, where the temperature inside an enclosure is often much higher than the room temperature.
Where 420207 fits and related parts
The DPX3 250 thermal-magnetic range runs from 100 to 250 A in 25, 36 and 50 kA, in three and four poles. Siblings in the same frame include 420205 (100 A, 25 kA), 420207 (160 A, 25 kA), 420208 (200 A) and 420209 (250 A), and the 36 kA version 420237 at 160 A. The magnetic-only 420719 suits motor feeders where overload is separate, while this thermal-magnetic device suits mixed distribution feeders. A trip-free switch version, the DPX3-I 250, exists for isolation without protection.
Selection checklist for 420207
- Load: set Ir between 128 and 160 A according to the cable and load current.
- Fault level: 25 kA at 380/415 V; choose the 36 or 50 kA version if the prospective current is higher.
- Temperature: apply the derating table above 40 °C inside the enclosure.
- Poles: three poles here; a four-pole version carries neutral protection at 100 % of phase.
- Accessories: shunt or undervoltage releases, rotary handles, interlocks and motor operator.
- Back-up and selectivity: check with the upstream device using the manufacturer tables.
Installation, setting and maintenance of 420207
Fix the breaker on a plate or rail, fit the connection plates for bars or lugs and the phase barriers, and keep the first conductor fixing point within the distance given in the data sheet (400 mm for 25 kA) to limit electrodynamic forces. Set Ir and Ii on the front dials, and record 420207 with the settings. Operate the handle at planned outages and perform thermographic inspection of the terminals. Replace the breaker if it has interrupted a severe short circuit or shows signs of overheating.
Typical applications in Oman and the GCC
Distribution feeders for pump houses, workshops, camps and process buildings often use 160 A moulded-case breakers. With high summer temperatures, the derating table matters, and a well-ventilated enclosure helps keep the breaker at its rated current. Dust and humidity argue for IP-rated enclosures and routine cleaning.
Information to send with an RFQ for 420207
- Reference 420207 and the quantity, including spares for panel maintenance.
- Rated current (160 A), number of poles and breaking capacity (25, 36 or 50 kA).
- Cable size, load current and ambient temperature inside the board.
- Accessories such as rotary handle, shunt trip or motor operator.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as a technical data sheet or a compliance statement.
Storage, handling and spares for the Legrand 420207
Keep Legrand 420207 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the Legrand 420207 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The Legrand technical data sheet that covers 420207 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.
To request a quotation, send reference 420207, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.
Datasheets & Documents
- Datasheet Legrand 420207 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.
Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.
Legrand company profile
| Headquarters | Limoges, France |
|---|---|
| Listing | Euronext Paris |
| Brands | Legrand, Bticino, Cablofil, Zucchini |
| Product families | DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS |
Legrand DX3 circuit breakers
DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.
Ordering Legrand breakers: what we need
Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.
Facts checked against Legrand's published corporate information, October 2026.
Browse Legrand products by category: Circuit Breaker.
FAQ
Questions about the Legrand 420207 DPX3 250 Thermal-Magnetic MCCB 3P
Answers from our engineering team on installation, compatibility and integration.
01What is 420207?
It is a Legrand DPX3 250 thermal-magnetic moulded-case circuit breaker, three poles, 160 A, 25 kA at 400 V, with adjustable thermal and magnetic releases.
02What are the trip settings of 420207?
The thermal setting is 128 to 160 A (0.8 to 1.0 times In) and the magnetic setting is 800 to 1600 A (5 to 10 times In), according to the catalogue and data sheet.
03How does temperature affect 420207?
For the 160 A rating the data sheet lists a maximum long-time setting of 160 A at 40 and 50 °C, 143 A at 60 °C and 134 A at 70 °C, so enclosure heat reduces the usable current.
04What breaking capacity does 420207 have?
The data sheet gives Icu 25 kA at 380/415 V and 40 kA at 220/240 V, with Ics at 100 % of Icu and a making capacity of 52.5 kA at 415 V.
05How is 420207 different from 420719?
420207 has thermal and magnetic releases and 25 kA capacity, while 420719 is magnetic only with 36 kA capacity and needs a separate overload relay.